Veikong VK100 0R2G1 User Manual Download Page 21

 

21

 / 

24

 

 

c) The water pump is under restart delay status. 

Check focus and countermeasures: 

a) Check the water level of water storage device to see if water overflows. 

b) The parameters shall be set again: “U XX” shall be made to be in consistency with 

the type of the overflow level sensor applied. 

c) Alternatively, resetting shall be made by pressing up/down key on the panel at the 

same time to cancel the restarting delay or wait the delay time set. 

 

7.3 This Inverter will not start automatically if the sunlight is good. 

Cause: 

a) This Inverter is not under automatic working mode. 

b) The starting voltage is set too high. 

c) Failing to connect optical sensor or short circuit terminal PR1 and PR2. 

Check focus and countermeasures: 

a) This Inverter is under automatic working mode. 

b) By reducing the value of the starting voltage. 

c) By connecting optical sensor or short circuiting terminal PR1 and PR2.  

 

7.4 This Inverter is started when the sunlight is good and output is available but the 

water pump does not operate. 

Phenomenon:   

This  Inverter  is  started  when  the  sunlight  is  good  but  the  water  pump  does  not 

operate. 

Cause: 

a) The photovoltaic battery array does not point to the sun and the output power of it 

is insufficient. 

b)  Fault  happens  to  the  connection  of  photovoltaic  battery  array,  one  or  several 

groups  of  photovoltaic  battery  array  have  no  output  and  the  output  power  of 

photovoltaic battery array is insufficient. 

Check focus and countermeasures: 

Summary of Contents for VK100 0R2G1

Page 1: ...VK100 Series Smart Single Phase Solar inverter User Manual...

Page 2: ...ump Solar photovoltaic battery array means transmitting the solar radiation energy into DC electric energy which is adjusted by the photovoltaic pump inverter The solar panel nonlinear DC power is tra...

Page 3: ...ical management of desert and barren mountain supply of clean domestic water for both humans and livestock municipal sewerage treatment landscape fountain of urban square water conservancy facilities...

Page 4: ...ion of solar photovoltaic battery array power configured according to the requirements for water withdrawal on site the model and power of the water pump shall be determined according to the hydraulic...

Page 5: ...s provided with soft start function and is free from impact current so that it can remove water hammer totally It shall be configured with the battery panel with small power which can reduce the costs...

Page 6: ...amiliar with the high voltage line and electrical hazards shall be liable for the installation and check of this Inverter The hazards caused by incorrect operation may cause serious injury or even dea...

Page 7: ...ble 5 Never install this Inverter outdoors directly since it shall avoid direct sunshine It is not allowed to start stop the motor with contactor without consulting the manufacturer The internal power...

Page 8: ...gap which is no shorter than 15cm shall be left on the top and at the bottom of this Inverter 2 Sufficient space shall be left surrounding this Inverter so as to facilitate maintenance 3 Please use th...

Page 9: ...e isolation switch between the power and this Inverter shall be set If the wire noise or instantaneous voltage becomes too large isolation transformer or wire reactor can be used to provide this Inver...

Page 10: ...ilter at the output side of this Inverter since this will damage this Inverter It also may damage the capacitor and surge filter 6 The load other than single phase squirrel cage motor is prohibited Th...

Page 11: ...solar panels is connected with L1 L and L2 N If it is solar and power automatic switching models then connected with P and P terminals and single phase 230V AC power is connected with L1 L and L2 N te...

Page 12: ...drainage water level sensor LW Control terminal Input of detection signal of supply water level sensor COM Control terminal COM is the public terminal of all control terminals Reserved input terminal...

Page 13: ...ical sensor RA and RB are a pair of normally open contacts of the relay the overload capacity of contact 1A 230VAC It is connected after the operation of this Inverter 3 0 Panel and Operation Instruct...

Page 14: ...he detection of water level The output of water level detection sensor of water pump is disconnected LL means valid connection The output of overflow sensor of water pump is connected HH means valid d...

Page 15: ...own key at the same time after water level alarming occurs 4 0 Parameters The parameters that may need adjusting in installation and usage are shown in the table below No Parameters Parameter function...

Page 16: ...the table are the factory parameters which shall not be adjusted arbitrarily unless the factory informs it clearly If LL or OF alarming happens to this Inverter it can not be started again until the...

Page 17: ...h the requirements Check if the water pump inverter satisfies the installation and connection requirements Check if the water pump and pipeline satisfy the operation requirements Adjust the photovolta...

Page 18: ...y the following factors Too small power output by solar battery array Unreasonable design of photovoltaic pump system 6 0 Automatic Operation After the equipment is installed and connected and the inv...

Page 19: ...gy and electric supply the electric supply will be used automatically if the power of solar photovoltaic battery is not enough to drive the water pump to yield water If however the power of the photov...

Page 20: ...evel sensor of water supply works b The output type parameter F XX of water level sensor of water supply is set by mistake c The water pump is under restart delay status Check focus and countermeasure...

Page 21: ...to connect optical sensor or short circuit terminal PR1 and PR2 Check focus and countermeasures a This Inverter is under automatic working mode b By reducing the value of the starting voltage c By co...

Page 22: ...to the connection of photovoltaic battery array one or several groups of photovoltaic battery array have no output and the output power of photovoltaic battery array is insufficient Check focus and c...

Page 23: ...this Inverter b Abnormal internal detection protection line of this Inverter c Abnormal water pump Check focus and countermeasures a Configure the matched power of the water pump or this Inverter cor...

Page 24: ...ltage AC230V 1 PHASE Scope of output frequency 0 50 60Hz Cooling mode Forced air cooling Service environment Capacity can be reduced if above 10 50 Altitude 1000 m or below Weight kg 1 6 1 8 1 8 2 2 2...

Reviews: