Veikong VK100 0R2G1 User Manual Download Page 12

 

12

 / 

24

 

 

Functions of control terminal 

Category   

Terminal 

signal 

Terminal 

name 

Terminal function 

Remarks 

 

Power 

terminal   

 

L1/L, 

L2/N 

Input  terminal 
of solar power 

Power  connecting 
solar panels 

Pay  attention 
to  the  input 
and  output  to 
avoid 
connection 

P+, P- 

 

 

U/T1, 

V/T2,   

Output 
terminal 

of 

inverter 

Output 

connects 

motor 

Earthing 
terminal 

Earthing 

 

Control 

terminal 

of input 

signal 

PR1 

Control 
terminal 

Input 

of 

optical 

sensor 

 

PR2 

Control 
terminal 

Input 

of 

optical 

sensor 

 

OF 

Control 
terminal 

Input  of  detection 
signal  of  overflow 
(drainage) 

water 

level sensor 

 

LW 

Control 
terminal 

Input  of  detection 
signal 

of 

supply 

water level sensor 

 

 

 

 

 

COM 

Control 
terminal 

COM  is  the  public 
terminal 

of 

all 

control terminals 

 

Reserved 
input 
terminal   

RE1 

 

 

 

AU 

 

 

 

SP 

 

+24V 

 

Output 

signal 

terminal 

RA 

RA and RB 

are normally 

open contacts 

of the relay 

Relay outputs 

normally open 

contacts 

RA and RB 

are closed 

after the 

operation of 

this Inverter 

RB 

COM  is  the  public  terminal  while  LW  and  COM  are  the  terminals  for  the  water 

shortage protection interfaces. Both can be connected with the water level monitoring 

sensor of the water source. The sensor type can be set by parameters  (if it is set as 

FHH, the disconnection of the sensor is valid;  for the protection when the sensor is 

Summary of Contents for VK100 0R2G1

Page 1: ...VK100 Series Smart Single Phase Solar inverter User Manual...

Page 2: ...ump Solar photovoltaic battery array means transmitting the solar radiation energy into DC electric energy which is adjusted by the photovoltaic pump inverter The solar panel nonlinear DC power is tra...

Page 3: ...ical management of desert and barren mountain supply of clean domestic water for both humans and livestock municipal sewerage treatment landscape fountain of urban square water conservancy facilities...

Page 4: ...ion of solar photovoltaic battery array power configured according to the requirements for water withdrawal on site the model and power of the water pump shall be determined according to the hydraulic...

Page 5: ...s provided with soft start function and is free from impact current so that it can remove water hammer totally It shall be configured with the battery panel with small power which can reduce the costs...

Page 6: ...amiliar with the high voltage line and electrical hazards shall be liable for the installation and check of this Inverter The hazards caused by incorrect operation may cause serious injury or even dea...

Page 7: ...ble 5 Never install this Inverter outdoors directly since it shall avoid direct sunshine It is not allowed to start stop the motor with contactor without consulting the manufacturer The internal power...

Page 8: ...gap which is no shorter than 15cm shall be left on the top and at the bottom of this Inverter 2 Sufficient space shall be left surrounding this Inverter so as to facilitate maintenance 3 Please use th...

Page 9: ...e isolation switch between the power and this Inverter shall be set If the wire noise or instantaneous voltage becomes too large isolation transformer or wire reactor can be used to provide this Inver...

Page 10: ...ilter at the output side of this Inverter since this will damage this Inverter It also may damage the capacitor and surge filter 6 The load other than single phase squirrel cage motor is prohibited Th...

Page 11: ...solar panels is connected with L1 L and L2 N If it is solar and power automatic switching models then connected with P and P terminals and single phase 230V AC power is connected with L1 L and L2 N te...

Page 12: ...drainage water level sensor LW Control terminal Input of detection signal of supply water level sensor COM Control terminal COM is the public terminal of all control terminals Reserved input terminal...

Page 13: ...ical sensor RA and RB are a pair of normally open contacts of the relay the overload capacity of contact 1A 230VAC It is connected after the operation of this Inverter 3 0 Panel and Operation Instruct...

Page 14: ...he detection of water level The output of water level detection sensor of water pump is disconnected LL means valid connection The output of overflow sensor of water pump is connected HH means valid d...

Page 15: ...own key at the same time after water level alarming occurs 4 0 Parameters The parameters that may need adjusting in installation and usage are shown in the table below No Parameters Parameter function...

Page 16: ...the table are the factory parameters which shall not be adjusted arbitrarily unless the factory informs it clearly If LL or OF alarming happens to this Inverter it can not be started again until the...

Page 17: ...h the requirements Check if the water pump inverter satisfies the installation and connection requirements Check if the water pump and pipeline satisfy the operation requirements Adjust the photovolta...

Page 18: ...y the following factors Too small power output by solar battery array Unreasonable design of photovoltaic pump system 6 0 Automatic Operation After the equipment is installed and connected and the inv...

Page 19: ...gy and electric supply the electric supply will be used automatically if the power of solar photovoltaic battery is not enough to drive the water pump to yield water If however the power of the photov...

Page 20: ...evel sensor of water supply works b The output type parameter F XX of water level sensor of water supply is set by mistake c The water pump is under restart delay status Check focus and countermeasure...

Page 21: ...to connect optical sensor or short circuit terminal PR1 and PR2 Check focus and countermeasures a This Inverter is under automatic working mode b By reducing the value of the starting voltage c By co...

Page 22: ...to the connection of photovoltaic battery array one or several groups of photovoltaic battery array have no output and the output power of photovoltaic battery array is insufficient Check focus and c...

Page 23: ...this Inverter b Abnormal internal detection protection line of this Inverter c Abnormal water pump Check focus and countermeasures a Configure the matched power of the water pump or this Inverter cor...

Page 24: ...ltage AC230V 1 PHASE Scope of output frequency 0 50 60Hz Cooling mode Forced air cooling Service environment Capacity can be reduced if above 10 50 Altitude 1000 m or below Weight kg 1 6 1 8 1 8 2 2 2...

Reviews: