SI30 Solar Pump Inverter Manual
27
FE.16
Low speed protection
auto restore working
time
0.0
~
3000.0s
10.0s
●
0xE10
FE.17
Dry run protection
detect current
0.0
~
999.9A
0.0A
●
0xE11
FE.18
Dry run protection
detect time
0.0
~
3000.0s
10.0s
●
0xE12
FE.19
Dry run auto restore
working time
0.0
~
3000.0s
10.0s
●
0xE13
FE.20
Over current
protection detect
current
0.0
~
999.9A
0.0A
●
0xE14
FE.21
Over current
protection detect time
0.0
~
3000.0s
10.0s
●
0xE15
FE.22
Over current
protection auto restore
working time
0.0
~
3000.0s
10.0s
●
0xE16
FE.23
minimum power
protection value
0.00
~
650.00kw
0.00kw
●
0xE17
FE.24
Minimum power
protection detect time
0.0
~
3000.0s
10.0s
●
0xE18
FE.25
Minimum power
protection auto restore
working time
0.0
~
3000.0s
10.0s
●
0xE19
FE.26
Fault alarm restore
mode
0
:
Auto reset;1
:
manually reset
LED0
:
Low frequency protection
LED1
:
Dry run protection
LED2
:
Over current and overload
protection
LED3: Minimum power protection
0000
●
0xE1A
FE.27
Water fulfilled
protection detect time
0.0s
~
3000.0s
10.0s
●
0xE1B
FE.28
Water fulfilled
protection exist time
0.0s
~
3000.0s
10.0s
●
0xE1C
FE.29
reserved
●
0xE1D
FE.30
DC current revise
offset
0.00
~
99.99A
0.0A
●
0xE1E
FE.31
DC current revise
proportion gain
0.0
~
999.9%
100.0%
●
0xE1F
FE.32
Power curve 0
0.00
~
99.99kw
0.50kw
●
0xE20
FE.33
Power curve 1
0.00
~
99.99kw
1.00kw
●
0xE21
FE.34
Power curve 2
0.00
~
99.99kw
1.50kw
●
0xE22
FE.35
Power curve 3
0.00
~
99.99kw
2.00kw
●
0xE23
FE.36
Power curve 4
0.00
~
99.99kw
2.50kw
●
0xE24
FE.37
Flow curve 0
0.0
~
999.9m
3
/h
0.0 m
3
/h
●
0xE25
FE.38
Flow curve 1
0.0
~
999.9m
3
/h
5.0 m
3
/h
●
0xE26