F4.13 

The second line of 
keypad display in 
running status 

LED "0"digit

The first group   

LED "00"digit

The second group 

LED "000"digit

The third group 

LED "0000"digit digit

The forth 

group 

CA42 

● 

0x40D 

F4.14 

The second line of 
keypad display at stop 
status 

LED "0"digit

The first group   

LED "00"digit

The second group 

LED "000"digit

The third group 

LED "0000"digit digit

The forth 

group 

CA42 

● 

0x40E 

★ 

Motor Parameters 

Functi
on 
code

 

Function name

 

Setting range and definition

 

Default 

setting

 

pro

per

ty

 

Comm. 

Add

 

F5.00 

Motor type 

0

Asynchronous motor

AM

 

1

Permanent magnet motor

PM

 

× 

0x500 

F5.01 

Poles of motor 

2

48 

 

0x501 

F5.02 

Rated power of motor 

0.4

1000.0kW 

model set 

 

0x502 

F5.03 

Rated frequency of 
motor 

0.01

maxi frequency   

model set 

 

0x503 

F5.04 

Rated speed of motor 

0

65000rpm 

model set 

 

0x504 

F5.05 

Rated voltage of 
motor 

0

1500V 

model set 

 

0x505 

F5.06 

rated current of motor 

0.1

2000.0A 

model set 

 

0x506 

F5.07 

Motor no load current    0.01

650.0A 

model set 

 

0x507 

F5.08 

Stator resistance 
Of motor 

0.001

65.000 

model set 

 

0x508 

F5.09 

Rotor resistance 
of motor 

0.001

65.000 

model set 

 

0x509 

F5.10 

Stator and rotor 
Inductance of motor 

0.1

6500.0mH 

model set 

 

0x50A 

F5.11 

Stator and rotor 
mutual inductance of 
motor 

0.1

6500.0mH 

model set 

 

0x50B 

F5.12 

Motor auto tuning 

0

No operation   

1

Rotary auto tuning   

2

Stationary auto tuning 

 

0x50C 

F5.21 

Stator resistance 
Of synchronous motor 

0.001

65.000 

model set 

 

0x515 

F5.22 

Shaft D inductance of 
synchronous motor 

0.01mH

655.35mH 

model set 

 

0x516 

F5.23 

Shaft Q inductance of 
(synchronous motor 

0.01mH

655.35mH 

model set 

 

0x517 

F5.24 

Back EMF of 
synchronous motor of 

0.1V

1000.0V 

model set 

 

0x518 

Summary of Contents for SI30 series

Page 1: ...isk of injury Installation Danger 1 Please install the solar pump inverter on metal or other nonflammable material and keep it away from the combustible material Otherwise there is danger of fire 2 No...

Page 2: ...r pump inverter otherwise it will damage the solar pump inverter Before Electrification Danger 1 Please make sure that voltage grade of power supply is consistent with solar pump inverter s rated volt...

Page 3: ...ctric Otherwise it will cause electric shock 2 Before maintaining and repairing the solar pump inverter please make sure the indicator lights of power supply have completely turned off Otherwise it ma...

Page 4: ...ding is around 450V 8 Solar panel can be connected in series or parallel For rated voltage 380V controller we suggest solar panel open circuit voltage should be between 620 750V 1 4 Technical Specific...

Page 5: ...pter 2 Installation and Wiring 2 1 Products Appearance 2 2 Open Cover Remove 4 fixed screws in the cover and turn from right to left to open the top cover as shown below Remove 4 fixed screws Turn fro...

Page 6: ...SI30 Solar Pump Inverter Manual 6 2 3 Inverter Dimension Dimensions for 4 kW and below are shown as follow 364 446 5 350 285 308 221 270 M6 installation hole 151 37...

Page 7: ...SI30 Solar Pump Inverter Manual 7 5 5kW dimension as follow 285 308 350 364 446 5 195 87 268 250 7 5 installation hole 299 151 37 195 87...

Page 8: ...RS485 differential communication 120 Voltage current analog input 0 10V 4 20mA Voltage current analog input GND P N DC Power Input AC DC Module P1 N1 COM 24V Maximum output of 24V auxiliary power is...

Page 9: ...SI30 Solar Pump Inverter Manual 9 2 5 Terminal diagram D3 model with output filter D5 model with output filter _ L N U V W U1 V1 W1 U1 V1 W1 _ S T U V W U1 V1 W1 U1 V1 W1 R...

Page 10: ...SI30 Solar Pump Inverter Manual 10 Inverter board terminal diagram Terminal diagram of control panel U1 V1 W1 _...

Page 11: ...t parameter group in menu interface Modify parameter while in modify interface Modify given frequency PID given torque or magnetic powder clutch given torque while at standby or condition monitoring s...

Page 12: ...Hz Spark Digital display given frequency Hz On Digital display output frequency A On Digital display actual output current V On Digital display input voltage V Spark Digital display output voltage S...

Page 13: ...example to introduce Motor Parameter Setting According to the motor nameplate F5 02 Motor rated power F5 03 motor rated frequency F5 04 motor rated speed F5 05 motor rated Voltage Other motor paramet...

Page 14: ...ital tube current value display area A zone current numeric unit display area ID GPRS ID of current connection Left drop down box FX parameter selection area Middle Dropdown box XX function code selec...

Page 15: ...n F0 02 0 Pressing the key to start it when it is in stop status While it is in running status press the key to stop it And user can also press the key to reset it when it is in fault status The Power...

Page 16: ...ation over limit Too start rotating motor Check power grid Restart until motor is stop completely or set F1 00 set for 1 or 2 E oU2 Over voltage during deceleration Deceleration time too small The dri...

Page 17: ...condition or select matching inverter Use variable frequency motor if long term low speed running is needed E oL2 AC drive overload V F curve is improper or boost torque is too big ACC time is too sho...

Page 18: ...tor and inverter Motor parameter setting mistake Check motor connection wire Detect after motor stopping totally Change inverter model Reset parameter according to nameplate E TE2 Motor rotation detec...

Page 19: ...and wiring E PAn Keyboard connect fault Keyboard wire fault Keyboard component damage Check keyboard wire Seek support from factory Rs485 comm unicati on fault Unsuitable baud rate setting Communicat...

Page 20: ...equency source X reference 0 digital reference of keyboard 1 Potentiometer of key board 8 PID control reference 0 0x003 F0 08 Digital frequency reference 0 00 maximum frequency 50 00Hz 0x008 F0 09 Max...

Page 21: ...id when power on 1 valid when power on LED 00 digit Terminal running command selection while running command given channel switchover 0 Terminal running command is invalid when switching 1 Terminal ru...

Page 22: ...rameters of keypad to AC drive 0 0x405 F4 11 The first line of keypad display in running status LED 0 digit First group display 0 Frequency given 1 Output frequency 2 Output current 3 Input voltage 4...

Page 23: ...tor 0 01 maxi frequency model set 0x503 F5 04 Rated speed of motor 0 65000rpm model set 0x504 F5 05 Rated voltage of motor 0 1500V model set 0x505 F5 06 rated current of motor 0 1 2000 0A model set 0x...

Page 24: ...ter time 1 0 000 0 100s 0 005s 0x603 F6 04 ASR switching frequency 1 0 00 50 00Hz 5 00Hz 0x604 F6 05 ASR Speed loop proportional gain 2 0 00 1 00 0 20 0x605 F6 06 ASR Speed loop integral time 2 0 01 1...

Page 25: ...d Protection Parameters Functi on code Function name Setting range and definition Default setting prop erty Comm Add FA 10 DC bus under voltage protection point 50 0 100 0 70 0 0xA0A Communication Con...

Page 26: ...t protection 6 Minimum power protection Read only 0xE01 FE 02 VOC voltage 0 0 999 9V Read only 0xE02 FE 03 CVT target voltage 70 0 95 0 81 0 0xE03 FE 04 MPPT upper limit voltage 20 0 200 0 100 0 0xE04...

Page 27: ...protection auto restore working time 0 0 3000 0s 10 0s 0xE19 FE 26 Fault alarm restore mode 0 Auto reset 1 manually reset LED0 Low frequency protection LED1 Dry run protection LED2 Over current and o...

Page 28: ...on 1100H 0xE34 FE 47 Fast frequency falling threshold 3 0 15 0 5 0 0xE35 FE 48 Constant torque frequency limit coefficient 80 0 150 0 100 0 0xE36 FE 49 Sudden voltage rising threshold 0 0 20 0 5 0 0xE...

Page 29: ...0 1 m3 Read only 2121H C 34 Cumulative total flow low position 0 1m3 Read only 2122H C 35 Cumulative total flow high position 0 1km3 Read only 2123H C 36 Generated power per day 0 01kwh Read only 212...

Page 30: ...eck if the pump motor direction is reversed b Q Well lit conditions the drive is in standby mode 0 00Hz A Check FE 01 observe what protection status is the drive currently and check whether the parame...

Page 31: ...Q The current fluctuation is huge when the pump is running A Check C 39 adjusting the value of F5 24 so the C 39 displays the value from 0 10 6 3 PV Water Pump Features A Dormancy Function During the...

Page 32: ...rminal is defined as the input of solar water fulfilled detection alarm reset signal The warning signal is shown as A Ful G Alarm Recovery Mode 0 automatic recovery 1 manual recovery This option is fo...