29
F12.33
1: REV
LED”00” digit: ACC/DEC time in this step
0: ACC/DEC time 1
1: ACC/DEC time 2
2: ACC/DEC time 3
3: ACC/DEC time 4
LED”000” digit: Reserved
LED”0000” digit: Reserved
0000
●
0xC21
F12.34
0000
●
0xC22
F12.35
0000
●
0xC23
F12.36
0000
●
0xC24
F12.37
0000
●
0xC25
F12.38
0000
●
0xC26
F12.39
0000
●
0xC27
F12.40
0000
●
0xC28
F12.41
0000
●
0xC29
F12.42
0000
●
0xC2A
F12.43
0000
●
0xC2B
F12.44
0000
●
0xC2C
F12.45
0000
●
0xC2D
F12.46-
F12.48
Reserved
F12.49
Swing frequency control
0: invalid
1: valid
0
●
0xC31
F12.50
Swing frequency amplitude
0: Relative to central frequency
1: Relative to max frequency
0
●
0xC32
F12.51
Reserved
0.0
~
100.0%
10.0%
●
0xC34
F12.52
Swing frequency amplitude
F12.53
Jump frequency amplitude
0.0
~
50.0%
10.0%
●
F12.54
Swing frequency rising time
0.00
~
650.00s
5.00s
●
0xC36
F12.55
Swing frequency falling time
0.00
~
650.00s
5.00s
●
0xC37
Communication Control Function Parameter Group
NO.
Function description
Range of setting and definition
Factory
default
Fea
ture
Address
F13.00
Main-slave machine selection
LED “0” digit: Modbus main-slave selection
0: Slave machine
1: Main machine
LED “00” /“000”/”0000”digit: reserved
0000
〇
0xD00
F13.01
485 communication address
1
~
247
1
〇
0xD01
F13.02
Communication baud rate
selection
LED“0” digit:485 communication
0:1200 bps 1:2400 bps
2:4800 bps 3:9600 bps
4:19200 bps 5:38400 bps
LED “00” /“000”/”0000”digit: reserved
0003
〇
0xD02
F13.03
Modbus data format
0: (N,8,1)format
1: (E,8,1) format
2: (O,8,1) format
3: (N,8,2) format
4: (E,8,2) format
5: (O,8,2) format
0
〇
0xD03
F13.04
Communication ratio setting
0.00
~
5.00
1.00
●
0xD04
F13.05
Modbus communication answer
delay
0
~
500ms
0ms
●
0xD05
F13.06
Modbus communication
overtime fault time
0.1
~
100.0s
1.0s
●
0xD06