12
Terminal
Name
Function definition
TA
Normally-open
contact
Can set the action and object by programme.
Max contact capacity: 3A/240VAC
TC
Y
Collector
open output
Can set the action and object by programme.
Max contact capacity:DC30V/50mA
+24V
Auxiliary
power
Max output: 24VDC/100mA
。
COM
Auxiliary
power output -
FWD
Forward
Short connect with (COM) valid.
REV
Reverse
Short connect with (COM) valid.
X1
Multi function contact
input X1
Short connect with (COM) valid.
Multi function input terminals can be programme set definition. Pls
refer F-01--F-04
。
X2
Multi function contact
input X2
X3
Multi function contact
input X3
X4
Multi function contact
input X4
AO
Analog output
Physical type of output signal:0--10V 0--20mA 4--20mA
frequency pulse output, selectable by function F-61/F-62 or switch
J1 J2 J3.
AS
Current analog input
As inverter control signal or feedback signal, can set the act range
and response speed by programme.
VS resistance
:
89KΩ, AS resistance
:
250Ω.
VS
Voltage analog input
+10V
Signal
auxiliary
power terminal
Max output 10VDC/50mA
。
GND
Signal
auxiliary
power terminal
Common auxiliary power of analog output, analog input signal.
A+
Communication
terminal A+
RS485 communication port
B-
Communication
terminal B-