Version 0.6
26 August 2004
Page 43 of 52
For use with Vega 50 8 FXS + 2 FXO – SIP version 09.02.05.2 T003 or greater.
© 2004 VegaStream Ltd.
Set Longest ring-off time = length of longest silence in the incoming ringing voltage
cadence
Set Shortest ring-on time = length of shortest ring in the incoming ringing voltage cadence
select
Table 1 lists the standard values to use in the UK and USA.
Table 1. Ring tones parameters
Country
UK
USA
Longest silence
2000ms
4000ms
Ring tone values
Shortest ring
400ms
2000ms