12
4 Mounting
VEGAPULS Air 23 • Autarkic device with measured value transmission via radio technology
64314-EN-230606
The device can only be mounted on the top of an IBC container in one
of the areas shown below:
100 mm
(3.94")
50 mm
(1.97")
150 mm (5.91"
)
480 mm (18.90"
)
130 mm (5.12"
)
300 mm (1
1.82"
)
1
2
3
4
5
Fig. 5: Mounting position on the tank ceiling
1 Recommended mounting position
2 Permissible mounting range
3 Filling opening
4 Cross strut
5 Vessel edge
To avoid air bubbles in the area of the adhesive surface, the selected
mounting position should be as flat as possible or slightly curved
outwards.
Note:
Mounting positions or vessel ceilings with an inwardly curved surface
are not suitable for fastening.
4.3 Mounting preparations
The intended mounting position must be dry and free of dust, oil and
grease before mounting the sensor.
Note:
For this reason, clean the container ceiling with the isopropanol-
based cleaning cloth supplied. After cleaning the surface, first allow it
to flash off well so that any residual solvent can evaporate.
Warning:
The 2-propanol contained in the cleaning cloth is highly flammable
and harmful to health. Observe the hazard warnings on the packaging
and the safety data sheet on our homepage.
Installation position
Mounting preparation
adhesive joint