1 For your safety

VEGAPULS 69 • 4 … 20 mA/HART - four-wire

47255-EN-140801

1.5  CE conformity

The device fulfills the legal requirements of the applicable EC guide

-

lines. By affixing the CE marking, we confirm successful testing of the 

product.

You can find the CE Certificate of Conformity in the download section 

of our homepage.

1.6  NAMUR recommendations

NAMUR is the automation technology user association in the process 

industry in Germany. The published NAMUR recommendations are 

accepted as the standard in field instrumentation.
The device fulfills the requirements of the following NAMUR recom

-

mendations:

• 

NE 21 – Electromagnetic compatibility of equipment

• 

NE 43 – Signal level for malfunction information from measuring 

transducers

• 

NE 53 – Compatibility of field devices and display/adjustment 

components

• 

NE 107 – Self-monitoring and diagnosis of field devices

For further information see www.namur.de.

1.7  Radio license for Europe

The instrument meets the LPR (Level Probing Radar) radio standard 

EN 302729-1/2.
It is approved for unrestricted use inside and outside of closed ves-

sels in countries of the EU and EFTA that have implemented this 

standard.
For operation outside of closed vessels, the following conditions must 

be fulfilled:

• 

The installation must be carried out by trained qualified personnel

• 

The instrument must be stationary mounted and the antenna 

directed vertically downward

• 

The mounting location must be at least 4 km away from the radio 

astronomy stations, unless special permission was granted by the 

responsible national approval authority

• 

When installed within 4 to 40 km of a radio astronomy station, 

the instrument must not be mounted higher than 15 m above the 

ground.

You can find a list with the respective radio astronomy stations in 

chapter "

Supplement

".

1.8  Environmental instructions

Protection of the environment is one of our most important duties. 

That is why we have introduced an environment management system 

with the goal of continuously improving company environmental pro-

tection. The environment management system is certified according 

to DIN EN ISO 14001.

Summary of Contents for VEGAPULS 69

Page 1: ...Quick setup guide Radar sensor for continuous level measurement of bulk solids VEGAPULS 69 4 20 mA HART four wire Document ID 47255...

Page 2: ...r housing 11 5 Set up with the display and adjustment module 5 1 Insert display and adjustment module 13 5 2 Parameter adjustment Quick setup 13 5 3 Parameter adjustment Extended adjustment 15 6 Suppl...

Page 3: ...t instrument complying with all prevailing regulations and guidelines The instrument must only be operated in a technically flawless and reliable condition The operator is responsible for the trouble...

Page 4: ...ets the LPR Level Probing Radar radio standard EN 302729 1 2 It is approved for unrestricted use inside and outside of closed ves sels in countries of the EU and EFTA that have implemented this standa...

Page 5: ...safety VEGAPULS 69 4 20 mA HART four wire 47255 EN 140801 Please help us fulfill this obligation by observing the environmental instructions in this manual Chapter Packaging transport and storage Chap...

Page 6: ...12 Data Matrix Code for Smartphone App 13 Symbol of the device protection class 14 ID numbers instrument documentation 15 Reminder to observe the instrument documentation 16 Notified authority for CE...

Page 7: ...4 20 mA HART four wire 47255 EN 140801 Download the smartphone app VEGA Tools from the Apple App Store or the Google Play Store Scan the Data Matrix code on the type label of the instrument or Enter t...

Page 8: ...0 90 and 180 Double chamber housing Angle of inclination 90 infinitely variable Angle of inclination in two steps 0 and 90 3 2 Mounting instructions Radar sensors for level measurement emit electroma...

Page 9: ...radar sensor on the vessel top If you cannot maintain this distance you should carry out a false signal storage during setup This applies particularly if buildup on the vessel wall is expected In suc...

Page 10: ...ew the housing cover 2 Loosen compression nuts of the cable glands 3 Remove approx 10 cm 4 in of the cable mantle signal output strip approx 1 cm 0 4 in insulation from the ends of the indi vidual wir...

Page 11: ...n The electrical connection is finished Information The terminal blocks are pluggable and can be removed from the housing insert To do this lift the terminal block with a small screwdriv er and pull i...

Page 12: ...on IS GND 5 1 L N 2 6 7 8 Fig 6 Connection compartment with double chamber housing with low voltage Terminal Function Polarity 1 Voltage supply L 2 Voltage supply N 5 4 20 mA output active 6 4 20 mA o...

Page 13: ...in the desired position and turn it to the right until it snaps in 3 Screw housing cover with inspection window tightly back on Disassembly is carried out in reverse order The display and adjustment...

Page 14: ...this menu item you select the type of bulk solid The selection com prises different granulate sizes 3 Application Vessel bottom In this menu item you specify the application and the form of the ves s...

Page 15: ...adjustment 1 Min level max meas distance 2 Max level min meas distance 3 Reference plane If these values are not known an adjustment with the distances of for example 10 and 90 is possible Starting po...

Page 16: ...signal changes over time In addition the echo curve saved during setup can also be displayed in the echo curve window and compared with the actual echo curve The following circumstances cause interfe...

Page 17: ...signal suppression has already been created in the sensor the following menu window appears when selecting False signal suppression Delete An already created false signal suppression will be com plete...

Page 18: ...1 5 or NPT Wire cross section spring loaded terminals Massive wire stranded wire 0 2 2 5 mm AWG 24 14 Stranded wire with end sleeve 0 2 1 5 mm AWG 24 16 Voltage supply Operating voltage Version for lo...

Page 19: ...19 Notes VEGAPULS 69 4 20 mA HART four wire 47255 EN 140801...

Page 20: ...of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change without prior n...

Reviews: