61
10 Supplement
VEGAPULS 66 • 4 … 20 mA/HART - two-wire
28438-EN-170927
Housing material
Version
IP-protection class
NEMA protection
Aluminium
Single chamber
IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)
Type 6P
Type 6P
Double chamber
IP 66/IP 67
IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)
Type 4X
Type 6P
Type 6P
Stainless steel (electro-
polished)
Single chamber
IP 66/IP 68 (0.2 bar)
Type 6P
Stainless steel (precision
casting)
Single chamber
IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)
Type 6P
Type 6P
Double chamber
IP 66/IP 67
IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)
Type 4X
Type 6P
Type 6P
Connection of the feeding power supply
unit
Networks of overvoltage category III
Altitude above sea level
Ʋ by default
up to 2000 m (6562 ft)
Ʋ with connected overvoltage protection up to 5000 m (16404 ft)
Pollution degree
16)
4
Protection class
II (IEC 61010-1)
Functional safety (SIL)
Functional safety is already activated on instruments with SIL qualification ex factory. On instru-
ments without SIL qualification ex factory, the functional safety must be activated by the user via
the display and adjustment module or via PACTware for applications according to SIL.
Functional safety according to IEC 61508-4
Ʋ Single channel architecture (1oo1D) up to SIL2
Ʋ double channel diversitary redundant
architecture (1oo2D)
up to SIL3
You can find detailed information in the supplied Safety Manual of the instrument series or under
"www.vega.com", "
Downloads
", "
Approvals
".
Approvals
Instruments with approvals can have different technical specifications depending on the version.
For that reason the associated approval documents of these instruments have to be carefully
noted. They are part of the delivery or can be downloaded under www.vega.com "
Instrument
search (serial number)
" as well as in the general download area.
16)
When used with fulfilled housing protection