58
11 Supplement
VEGAPULS 65 • Foundation Fieldbus
36518-EN-140209
Ʋ
Max. spectral transmission power
density
+24 dBm/50 MHz EIRP
Ʋ Specific absorption rate (SAR)
0.47
mW/kg
Ambient conditions
Ambient, storage and transport tempera
-
ture
-40 … +80 °C (-40 … +176 °F)
Process conditions
For the process conditions, please also note the specifications on the type label. The lower value
always applies.
Process temperature (measured on the process fitting)
Ʋ Process fitting, thread PVDF
-40 … +130 °C (-40 … +266 °F)
Ʋ Other process fittings
-40 … +150 °C (-40 … +302 °F)
Vessel pressure
Ʋ
Screwed part PVDF
-1 … 2
bar (-100
… 200
kPa/-14.5
… 29.0
psig)
Ʋ Screwed part and flange 316L
-1 … 16
bar (-100
… 1600
kPa/-14.5
… 232
psig)
Vessel pressure relating to the flange
nominal stage
see supplementary instructions manual "
Flanges ac-
cording to DIN-EN-ASME-JIS
"
Vibration resistance
4 g at 5 … 200 Hz according to EN 60068-2-6 (vibration
with resonance)
Shock resistance
100
g, 6
ms according to EN
60068-2-27 (mechanical
shock)
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Options of the cable entry
Ʋ
Cable gland
M20
x
1.5 (cable: ø
5 … 9
mm)
Ʋ
Cable entry
½ NPT
Ʋ
Blind plug
M20
x
1.5; ½
NPT
Ʋ
Closing cap
M20
x
1.5; ½
NPT
Plug options
Ʋ
Signal circuit
Plug M12
x
1, according to ISO
4400, Harting HAN,
7/8"
FF
Ʋ
Indication circuit
M12
x
1 plug
Wire cross-section (spring-loaded terminals)
Ʋ
Massive wire, cord
0.2 … 2.5
mm² (AWG
24 …
14)
Ʋ
Stranded wire with end sleeve
0.2 … 1.5
mm² (AWG
24 …
16)
Electromechanical data - version IP 66/IP 68 (1 bar)
Options of the cable entry
Ʋ
Cable gland with integrated connec
-
tion cable
M20
x
1.5 (cable: ø
5 … 9
mm)
Ʋ
Cable entry
½ NPT
Ʋ
Blind plug
M20
x
1.5; ½
NPT