34
VEGAPULS 51K … 54K
21750-EN-031222
Electrical connection
2
-
+
4 … 20mA
2
2
2
4
1)
Measuring system with VEGAPULS 51K … 54K in four-wire technology
• Four-wire technology, power supply and output signal via two separate two-wire cables.
• Output signal 4 … 20 mA active.
• Optional external indicating instrument with analogue and digital indication (can be mounted
up to 25 m away from the sensor).
• Adjustment with PC, HART
®
handheld or adjustment module MINICOM (can be plugged into
the sensor or into the indicating instrument VEGADIS 50).
• max. resistance on the signal output (load) 500
Ω
.
(active)
2)
VEGADIS 50
1)
If the resistance of the processing systems
connected to the 4 … 20 mA signal output is less
than 250
Ω
, a resistor must be connected to the
connection cable during adjustment to get a loop
resistance of 250
Ω
.
The digital adjustment signal would otherwise be
severely damped or short-circuited due to
insufficient resistance of the connected
processing system. Digital communication with the
PC would not be ensured.
HART
®
handheld
VEGA-
CONNECT 2
≥
250
Ω
2)
4 … 20 mA active means that the sensor delivers
a level-dependent current of 4 … 20 mA (source).
The sensor reacts electrically in the processing
system (e.g. indication) like a current source.
Summary of Contents for VEGAPULS 51K
Page 1: ...Operating Instructions VEGAPULS 51K 54K 4 20 mA HART compact sensor...
Page 41: ...VEGAPULS 51K 54K 41 21750 EN 031222 Rx VEGAMET VEGALOG Ri 250 250 Ri 250 Set up PLC PLC...
Page 49: ...VEGAPULS 51K 54K 49 21750 EN 031222 Set up VEGALOG VEGAMET Rx...
Page 70: ...70 VEGAPULS 51K 54K 21750 EN 031222 Supplement CE declaration of conformity...
Page 71: ...VEGAPULS 51K 54K 71 21750 EN 031222 Supplement...