6
VEGAFLEX 62 – 4 … 20 mA/HART
®
2
7822-EN-030715
Connection to power supply
2.2 Wiring plans
Single chamber housing
Overview
4... 20mA
Display
Typ:
FX60H
Com.
1
2
5 6 7
8
1)
Connect cable screen here, connect ground terminal on
housing exterior to ground as prescribed (low-impedance).
The two terminals are galvanically connected.
Plastic
Aluminium
Stainless steel
Contact springs for adjust-
ment module PLICSCOM
Spring-loaded
terminals for
4…20 mA
connection
Spring-loaded
terminals for
connection of
VEGADIS 61
Plug connector
for VEGACON-
NECT 3
Ground terminal
1)
Fig. 2:
Overview of the three materials of the single chamber
housing
Top view, electronics and connection com-
partment
Fig. 3:
Top view of the electronics and connection compart-
ment
Wiring plan
Display
1 2
5
6
7
8
PC with
PACT
ware
TM
VEGADIS 61
Power
supply
14…36 V DC/
4…20 mA
Plug con-
nection
Fig. 4:
Wiring plan, single chamber housing
Double chamber housing
Overview
4... 20mA
Display
Typ:
FX60H
Com.
1
2
5 6 7
8
Contact springs for adjustment
module PLICSCOM
Plug con-
nection for
VEGACON-
NECT 3
Internal connec-
tion cable to
connection
compartment
Electronics
compartment
Connection com-
partment
Cable entry (pressure-tight
with Exd)
Fig. 5:
Double chamber housing
Top view, electronics compartment
Fig. 6:
Top view of the electronics compartment of the dou-
ble chamber housing