56
10 Supplement
VEGABAR 66 • 4 … 20 mA/HART - climate compensated
36738-EN-130321
Dead time
≤ 150 ms
Rise time
≤ 100 ms (10 … 90 %)
Step response time
≤ 250 ms (ti: 0 s, 10 … 90 %)
Damping (63
% of the input variable)
0
…
999
s, adjustable
Additional output parameter - temperature
Processing is made via output signal HART multidrop, Profibus PA and Foundation Fieldbus
Range
-50
…
+150
°C (-58
…
+302
°F)
Resolution
1
°C (1.8
°F)
Accuracy
Ʋ
in the range of 0
…
+100
°C
(+32
…
+212
°F)
±3
K
Ʋ
in the range of -50
…
0
°C
(-58
…
+32
°F) and +100
…
+150
°C
(+212
…
+302
°F)
typ. ±4
K
Input variable
Adjustment
Adjustment range of the min./max. adjustment relating to the nominal measuring range:
Ʋ
Percentage value
-10
…
110
%
Ʋ
Pressure value
-20
…
120
%
Adjustment range of the zero/span adjustment relating to the nominal measuring range:
Ʋ zero
-20
…
+95
%
Ʋ
span
-120
…
+120
%
11)
Ʋ Difference between zero and span
max. 120
% of the nominal range
Recommended max. turn down
10
:
1
Nominal measuring ranges and overload capability in bar/kPa
The specifications are only an overview and refer to the measuring cell. Limitations due to the ma
-
terial and version of the process fitting are possible. The specifications on the nameplate apply.
Nominal range
Overload capacity, max.
pressure
Overload capacity, min. pres-
sure
Gauge pressure
0
…
+0.2
bar/0
…
+20
kPa
+35
bar/+3500
kPa
-1
bar/-100
kPa
0
…
+0.4
bar/0
…
+40
kPa
+50
bar/+5000
kPa
-1
bar/-100
kPa
0
…
+1
bar/0
…
+100
kPa
+50
bar/+5000
kPa
-1
bar/-100
kPa
0
…
+2.5
bar/0
…
+250
kPa
+65
bar/+6500
kPa
-1
bar/-100
kPa
0
…
+5
bar/0
…
+500
kPa
+65
bar/+6500
kPa
-1
bar/-100
kPa
0
…
+10
bar/0
…
+1000
kPa
+90
bar/+9000
kPa
-1
bar/-100
kPa
0
…
+25
bar/0
…
+2500
kPa
+130
bar/+13000
kPa
-1
bar/-100
kPa
Nominal measuring ranges and overload capability in psig
11)
Values less than -1 bar cannot be set.