63138-US-200110
59
If the source is potentially leaky, perform the following steps:
•
Inform the radiation safety officer
•
Take suitable measures to avoid contamination of the environment by
securing the source.
•
Inform the responsible authority of the potentially leaky source.
7.3 Periodic Maintenance Schedule
The specified value is valid for the U.S. International regulations
may specify different values
Description
Frequency
Procedure
Source holder shutter
check ON/OFF
Mechanism (On
applicable source
holders)
Every six months
unless otherwise
required by applicable
nuclear regulatory
agency
See the Shutter (ON/OFF)
Mechanism procedure.
Source wipe/Leak test Every three years
unless otherwise
required by applicable
nuclear regulatory
agency
See the Leak Test procedure.
Location/Inventory
Annually unless
otherwise required by
applicable nuclear
regulatory agency
Ensure that the source holder
is in the correct location. If the
source is not in the correct
location, contact your
regulatory agency
immediately.
Mounting brackets and
hardware
Annually
Check for loose mounting
hardware.
Tags and labels
Annually
Make certain the tags and
labels are in place and legible.
!
NOTE
Summary of Contents for SHLD 2
Page 1: ...Operating Instructions SHLD 2 Source Holder Document ID 63138 Radiometric...
Page 2: ......
Page 8: ...6 63138 US 200110 NOTES...
Page 12: ...10 63138 US 200110 NOTES...
Page 26: ...24 63138 US 200110 NOTES...
Page 42: ...40 63138 US 200110 NOTES...
Page 56: ...54 63138 US 200110 NOTES...
Page 68: ...66 63138 US 200110 NOTES...
Page 78: ...76 63138 US 200110 9 2 Dimensions Figure 9 7 Source Holder SHLD 2 Standard Version...
Page 79: ...63138 US 200110 77 Figure 9 8 SHLD 2 Beam Angles Figure 9 9 SHLD 2 Height for Source Exchange...
Page 80: ...78 63138 US 200110 Figure 9 10 Source Holder SHLD 2 with Limit Switch...
Page 81: ...63138 US 200110 79 Figure 9 11 Source Holder SHLD 2 with Interlock Safety Switch...
Page 82: ...80 63138 US 200110 Figure 9 12 Source Holder SHLD 2 with Air Actuator...
Page 83: ...63138 US 200110 81 Figure 9 13 Source Holder SHLD 2 with Air Actuator and Limit Switch...
Page 84: ...82 63138 US 200110 Figure 9 14 Source Holder SHLD 2 Explosion Proof with Limit Switch...
Page 86: ...84 63138 US 200110 NOTES...
Page 87: ......