Vega SH-2 / User Manual
30
Revision 02
–
"temp":28,
"onewire":[28.2, 27.9, 28.3, 0, 0, 0, 0, 0, 0, 0],
}
}
Transcription of the message fields:
Message
–
part with information about current message.
firmware
–
name and version of the device firmware
num
–
number of the message sent by the SH-2 device
date
–
date of the message sending
time
–
time of the message sending
LBS
–
part with information about the gateway parameters which resend that packet
TAC, CID, MCC, MNC
–
gateway identifications
ACT
–
technology (9
–
LTE Cat.NB1)
SQ
–
gateway signal quality
CellStatus
–
part with information about the cellular state
EARFCN
–
the number of radio frequency channel (absolute)
PCID
–
physical network address
RSRP
–
input signal power
RSRQ
–
input signal quality
RSSI
–
indicator of the input signal power
SNR
–
signal to noise ratio
Telemetry
–
part with collected data (one packet)
reason
–
transmitting reason
date
–
date of the data collection
time
–
time of the data collection
bat
–
battery charge
pulse1
–
pulse number on the input 1
pulse2
–
pulse number on the input 2
ADC1
–
voltage value on the analog input 1
ADC2
–
voltage value on the analog input 2
temp
–
temperature of the processor
onewire
–
external temperature sensors
’
readings
modbus
2
–
data from the RS-485 interface from an external MODBUS device (10
values of 16-bit register)
2
If the MODBUS mode on, then that data will transmit instead of onewire data and vice versa