background image

ITEM

NE

W

QT

Y

TYPE

DESCRIPTION

PART NO. DESIGNATOR

This drawing, written description or specification Is 
a proprietary product of TELEX, Lincoln, NE, and 
shall not be released, disclosed, nor duplicated 
without the written permission of TELEX.

Telex Communications INC.

Lincoln, Nebraska USA

APPROVALS:

DR  BY: SBC

    DATE: 09/16/2003

  PROD:

CHK:

APPD:

879796

REV LEVEL:

PCB ASSY, NEO-10

TITLE:

PART NO:

1

37

10 RES

2.4K 0603

723488242T

R23 R24 R25 R26 R150 R181 R196 R371 
R372 R373

38

4 RES

0 OHM 0603

DO NOT PLACE R16 R43 R53 R54

39

2 RES

15 OHMS 0603

723488150T R162 R27

40

9 RES

10K 0603

723488103T R17 R18 R32 R77 R78 R79 R15 R138 R6

41

2 RES

0603 OPTIONAL

DO NOT PLACE R180 R195

42

1 RES

1.5K 0603 5%

723488152T R197

43

2 RES

0805 6.98k 1%

102515281T R29 R131

44

5 RES

0 OHM 0603

723488000T R3 R4 R5 R139 R166

45

32 RES

0805 10K 100V 1%

102515300T

R30 R31 R33 R60 R61 R70 R71 R72 R80 
R81 R83 R86 R88 R89 R93 R94 R98 R101 
R103 R105 R108 R109 R110 R113 R118 
R119 R124 R125 R126 R130 R388 R389

46

30 RES

0603 1k 5%

723488102T

R7 R8 R9 R10 R14 R28 R34 R36 R62 R69 
R73 R74 R84 R85 R90 R91 R99 R100 R106 
R107 R111 R112 R122 R123 R127 R128 
R129 R134 R136 R137

47

15 RES

47 OHMS 0805 5%

102506470T

R35 R37 R38 R40 R41 R42 R44 R45 R46 
R47 R48 R50 R51 R52 R57

48

4 RES

0805 1k 1%

102515200T R39 R132 R135 R142

49

1 RES

22.1K 0603 1%

723481333T R49

50

2 RES

220 OHMS 0805 5%

102506221T R55 R56

51

2 RES

470 OHMS 0603

723488471T R59 R58

52

1 RES

4.7K 0603

723488472T R63

53

2 RES

30.1K 1% 0603

723481346T R75 R13

54

1 RES

33.2K 1% 0603

723481350T R76

55

1 RES

2.2M 0805 5%

102506225T R82

56

8 RES

0805 OPTIONAL

DO NOT PLACE R87 R96 R97 R116 R117 R120 R121 R147

57

26 RES

56 OHMS 0603 1%

723481072T

R92 R95 R157 R158 R159 R160 R161 R182
R183 R186 R188 R189 R190 R191 R192 
R193 R194

58

1 SWITCH

SMT TACT SWITCH

700182T S1

59

1 XFMR

PE-68515L 10/100 ETHERNET XFMR

730154S T3

60

1 IC

NET+50 760342 U1

61

1 IC

TC7S86FU

760343S U12

62

1 IC

512Kx16 FLASH ATMEL/AMD

7603444PS U13

63

2 IC

SN74LVC541ADWR  SMT

760256T U14 U18

64

2 IC

MT48LC4M16A2-75 4Mx16 SDRAM

760501S U16 U17

65

1 IC

74HC00 QUAD NAND

17-03-051986T U19

66

2 IC

LT1086CM-33 3.3V REGULATOR

511155000S U2 U28

67

1 IC

MAX3232CSE S016

760349S U20

68

2 IC

SN74LVC574ADW  SMT

760257T U22 U23

69

1

IC SOCKET

PLCC SOCKET 44

539030044 FOR U24

70

X

1 IC

7032 NEO

76026718PS U24

71

1 IC

SN74LVC541ADWR  SMT

DO NOT PLACE U25

72

2 IC

74LCX245 Bi-Directional 8bit Bus Chip DO NOT PLACE U26

73

4 IC

LM317 ADJ REGULATOR, SMT

760250T U3 U4 U27 U29

LN,BE

Page 3 of 5

Summary of Contents for NEO-10

Page 1: ...Model NEO 10 Version 1 0 Technical Manual November 26 2003 PN 803968 ...

Page 2: ...NAL 5 3 2 GENERAL SETUP VIA WEB PAGES 8 3 3 BASIC ETHERNET SETUP SCREEN 8 3 3 1 Use DHCP Server 8 3 3 2 Unit IP Address 8 3 3 3 Subnet Mask 8 3 3 4 Gateway Address 8 3 3 5 DNS Addresses 1 3 8 3 4 MULTICAST SETUP 10 3 5 DEBOUNCE INPUT SETTINGS 11 3 6 ECHO PACKET 12 3 7 CLONE FROM OTHER NEO 14 3 8 PIN CHANGE 15 3 9 SAVE CHANGES TO EEPROM 16 4 BILL OF MATERIAL AND SCHEMATICS 17 5 WARRANTY SERVICE REP...

Page 3: ... Version 2 52 of C Soft supports control and monitoring functions to support multiple NEO devices on the network Later releases of software for the desktop VoIP capable consoles will support NEO as well In addition to the I O functions of the device NEO supports 10 channels of echo packet functionality Echo Packet is a method of copying voice data content on the network from and to multicast addre...

Page 4: ... 2 3 Relay Input Ports There are 10 RJ45 ports that are used to sense inputs and control external events Each connector is connected to a DPDT relay Both sets of poles are brought out to the connector allowing for two separate circuits to be controlled by a single relay Figure 1 shows the pin out of the rear RJ45s Relay1 designates the pins on one half of the DPDT relay and Relay2 the other half T...

Page 5: ...h as Netscape or Internet Explorer Before connecting to the adaptor with the browser an IP address and Mask that is compatible with the users existing network must be set See your network administrator to determine the proper values Once these values have been set the unit must be reset for them to take affect To change the IP and Mask addresses using a Hyper Terminal program follow these simple s...

Page 6: ...6 At the main Hyper Terminal screen type uppercase S then enter Enter technobabble for the factory password ...

Page 7: ...o you want to change E Current Gateway address do you want to change F Do you want to reset any of the above Once all parameters have been entered and saved allow the unit to reset by answering Yes to the final question The unit will reset in 10 20 seconds Startup text will be sent to the serial port allowing verification of the setup parameters having been recorded correctly A B C D E F ...

Page 8: ...st turned on Since it is important that the NEO always be located in a known location for all consoles utilizing it on the network this should not be used as the normal operating mode It is useful sometimes to determine the settings that might be used for a particular network or testing 3 3 2 Unit IP Address In addition to the method outlined in section 3 1 the base IP address can be changed from ...

Page 9: ... parameters are set press the Submit button to send them back to the NEO from the web browser The parameters are not updated until they are actually saved to EPROM Section 3 9 Figure 3 Basic Ethernet Setup Screen ...

Page 10: ...s a unique port to which the multicast packet will be sent Channel Hops is the number of routers that the packet will penetrate before being stopped and allowed to propagate no further The Multicast Address and Port Number must match those set within the console It is Okay to use the same Multicast Address and Port number in multiple NEO devices The base IP address is used to differentiate the sou...

Page 11: ...econds that the input is allowed to stabilize from first change detection to final sampling The timer resolution is only 20ms so multiples of 20ms must be used Other values will work but give no finer resolution Once all values have been set press the Submit button to send the values to the NEO Save to EEPROM to make them permanent Section 3 9 Figure 5 Input Debounce Settings ...

Page 12: ...y The parameters of the NEO are delineated by a dash between each value The values correspond to the entry fields per line of the NEO setup screen shown in Figure 7 Note that RX traffic is a single direction copy Packets received are copied only to the RX MCast address Note that traffic received to the RX multicast address will be recopied back out Since there should only be one receive source on ...

Page 13: ...13 Figure 7 Echo Packet Setup ...

Page 14: ... NEO to be copied to another over the network Simply enter the IP address of the unit to copy the parameters from and press the submit button The parameters will be copied The only parameters that are not copied are the PIN number IP address and Mask Figure 8 Clone from Other NEO ...

Page 15: ...hange The PIN number is the password required to enter the setup mode of the NEO The default is no PIN number The PIN number is a 4 digit number that must be entered twice and then submitted Figure 9 Set PIN Number ...

Page 16: ...M As each group of settings are changed and submitted they still must be saved to EEPROM to be stored permanently Some settings require reboot of the device to take effect These are primarily IP parameters Figure 10 Save to EEPROM ...

Page 17: ...17 4 BILL OF MATERIAL AND SCHEMATICS ...

Page 18: ...fication Is a proprietary product of TELEX Lincoln NE and shall not be released disclosed nor duplicated without the written permission of TELEX Telex Communications INC Lincoln Nebraska USA APPROVALS DR BY SBC DATE 09 16 2003 PROD CHK APPD 879796 REV LEVEL PCB ASSY NEO 10 TITLE PART NO 1 LN BE PAGE 1 OF 5 ...

Page 19: ...26 D28 D30 D32 D33 19 10 LED RT ANG DUAL VERT LED RED 760506 D9 D12 D15 D18 D21 D24 D27 D29 D31 D34 20 1 FUSE SMT FUSE WITH HOLDER 5A SLO BLO 7101052T F44 21 16 FERRITE 0805 FERRITE BEAD 723511T FB1 FB2 FB3 FB4 FB5 FB6 FB7 FB8 FB9 FB10 FB11 FB12 FB13 FB14 FB22 FB23 22 1 FERRITE COMMON MODE FB 724039T FB44 23 1 CONN EMULATION HEADER 640125 J1 24 1 CONN 20 PIN SURFACE MOUNT HEADER DO NOT PLACE J12 2...

Page 20: ... 47 15 RES 47 OHMS 0805 5 102506470T R35 R37 R38 R40 R41 R42 R44 R45 R46 R47 R48 R50 R51 R52 R57 48 4 RES 0805 1k 1 102515200T R39 R132 R135 R142 49 1 RES 22 1K 0603 1 723481333T R49 50 2 RES 220 OHMS 0805 5 102506221T R55 R56 51 2 RES 470 OHMS 0603 723488471T R59 R58 52 1 RES 4 7K 0603 723488472T R63 53 2 RES 30 1K 1 0603 723481346T R75 R13 54 1 RES 33 2K 1 0603 723481350T R76 55 1 RES 2 2M 0805 ...

Page 21: ...PROVALS DR BY SBC DATE 09 16 2003 PROD CHK APPD 879796 REV LEVEL PCB ASSY NEO 10 TITLE PART NO 1 74 1 IC Intel LXT791ALC 760533 U49 75 5 IC 74LCX245 Bi Directional 8bit Bus Chip 760255 U5 U9 U10 U11 U15 76 1 IC TC7S32FU 760503S U6 77 2 IC TC7S08FU 760504S U7 U21 78 1 IC TPS70102PWP 760505S U8 79 1 XTAL 44 2368MHz 3 3V OSC 780191S Y1 80 1 XTAL 25 000MHZ SMT 780189S Y5 81 X 1 PCB PRINTED CIRCUIT BOA...

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ......

Page 26: ...r consequential damages Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives the customer specific legal rights and there may be other rights which vary from state to state Factory Service Center TELEX Communications Inc Vega Signaling Products 8601 East Cornhusker Highway Lincoln Nebraska 68507...

Reviews: