background image

 

 

Vega NB-13 / User Manual 

 

 

Revision 06 of 24 January 2022  

 

1 DEVICE PURPOSE AND OPERATION PRINCIPAL 

DEVICE  PURPOSE 

Vega NB-13 modem with RS-232/RS-485 interface is designed for the data collection 

from the external devices connected through RS-232/RS-485 interfaces and transmitting them 
to the server by the NB-IoT technology.  

In addition, Vega NB-13 can be used as a security device – two additional inputs operate 

in security mode, there is also a Hall sensor.  

The  modem with RS-232/RS-485 interface can be used for any utilities’ meters and 

industrial equipment with RS-232 or RS-485 interface or for the periodic collection of 
temperature values from the 1-Wire sensors.  

RS-232 and RS-485 have the separate contacts but they can’t operate at the same time. 

You can choose it at a software level while setting the device. 

Vega NB-13 has an external NB-IoT antenna and ingress protection rating IP67. Also, 

modem has an output for external devices powering with 8 V. 

The counter is powered by an external supply with power 5…55 V. 

OPERATION ALGORITHM 

Modem can operate in two modes: in the transparent mode the Vega NB-13 modem 

does not collect data, in the data collection mode the data collection and communication are 
carried out by the schedule. 

In the “Transparent” mode, the modem opens a transparent radio channel between the 

device connected via the RS-485/RS-232 interface and the TCP server. After connecting the 
power, the device immediately opens the communication channel if the timeout of the 
transparent channel session is not set, and the session is supported indefinitely. If the timeout 
is set, then the session closes automatically after the timeout. Opening a session can be 
performed: when the power is connected (only when the timeout is not set), during an event 
at the security input, by the Hall sensor, by the button (holding  up to two LED flashes), by 
command from the configurator. In the transparent mode, the modem does not accumulate 
data in the black box. 

In the “Data collection” mode  the readings are  collected  from the meter with a 

configurable period 5, 15, 30 minutes, 1, 6, 12 or 24 hours. The readings stored in the device 
memory and transmitting during the next communication session with the NB-IoT network. 
The adjustable data transfer period can be equal to 5, 15, 30 minutes, 1, 6, 12 and 24 hours. Data 
transferring in random point in time during set period. At the next communication session, the 
device starts sending accumulated packets with readings, from the earliest to the latest. If there 
is no network registration or server connection the undelivered packets are saved in the device 
memory until the next communication session according to the schedule. Herewith, the device 

Summary of Contents for VEGA NB-13

Page 1: ...www vega absolute ru NB IOT MODEM WITH RS 232 RS 485 INTERFACE VEGA NB 13 USER MANUAL DOCUMENT REVISION FIRMWARE VERSION 06 0 9...

Page 2: ...SPECIFICATION 6 Device Specification 6 Default Device Settings 7 3 OPERATION 8 Device Appearance 8 Contacts 10 ModBus Settings Tab 12 Connection Of Terminator 14 Hall Sensor 15 Buttons 16 Indication 1...

Page 3: ...des information on powering and activation procedure control commands and functions of the counter This manual is targeted at specialists familiar with installation work fundamentals of electronic and...

Page 4: ...the Transparent mode the modem opens a transparent radio channel between the device connected via the RS 485 RS 232 interface and the TCP server After connecting the power the device immediately open...

Page 5: ...onfigurator via USB FUNCTIONAL Vega NB 13 modem has the following features RS 232 or RS 485 interface Requests through ModBus protocol 1 Wire interface for connection of temperature sensors up to 10 i...

Page 6: ...Operating temperatures 40 85 Built in temperature sensor yes Hall sensor yes Quantity of black box records up to 100 000 CELLULAR COMMUNICATIONS Supported Cellular Standards LTE Cat NB1 Data transfer...

Page 7: ...Data collection period 24 hours Time zone UTC 00 00 Guard inputs operate on short Hall sensor ON Send network statistics OFF For changing the device settings you need to connect to it with Vega NB Io...

Page 8: ...rail The device case is equipped with a hermetic gland of M12 size A sealant is installed inside the gland ensuring compliance with the declared Ingress Protection rating of the device case 2 cable g...

Page 9: ...uary 2022 All of elements for manage and indication as well as connecting contacts are placed on the board inside the case 4 input for connecting an external antenna 5 contacts 6 USB port 7 LED indica...

Page 10: ...85_B Interface RS 485 B 9 RS232Tx Interface RS 232 Tx 10 RS232Rx Interface RS 232 Rx 11 8V Output power 8 V for external devices 12 GND Ground 13 VPWR External power 5 55 V 14 GND Ground RS 232 and RS...

Page 11: ...ower up the ModBus device connected to it before polling it for this use the 8V contact 1 Wire interface allows to connect there up to 10 temperature sensors see details in part 4 There are two securi...

Page 12: ...ModBus functionality The modem additionally polls the ModBus device by events and puts the received data into a black box When sending to the server the modbus key with data is added to the JSON mess...

Page 13: ...from the ModBus device The data is displayed in cells with the name A B C D E F G H Each cell displays a byte in HEX format If fewer bytes are read then unused cells are darkened and 00 is displayed i...

Page 14: ...r with nominal of 120 Ohm which is inactive by default For resistor activation you need to install a jumper at the XP1 connector on the board Terminator is used for defense from distortion in long tra...

Page 15: ...January 2022 HALL SENSOR The device has Hall sensor which located on the board edge on the bottom side When the magnet is brought up the sensor triggers and the device can form the alarm message whic...

Page 16: ...ading INIT Pressing for 1 second Registration at the network Pressing for 2 seconds Data transmitting Pressing for 3 seconds LTE modem switching off When you hold down the button the red LED starts fl...

Page 17: ...em Short flash every three seconds Device search the network Short flash every second Device successfully registered and it is in the network Two short flashes every one second Device transmits data t...

Page 18: ...in the office 3 De energizing the connected equipment metering devices etc 4 Placement the wires in the cable gland It must be remembered that the wires must be united in one cable of circular cross...

Page 19: ...to test the data transmitting then press and hold the INIT button for the 2 seconds 8 Before assembling the device you can reset the pulses accumulated during testing and connection through the Vega N...

Page 20: ...ed and a client name the name which the device use for publishing All those settings specified in Vega NB IoT Configurator in part MQTT settings For watching the data sending by the device you should...

Page 21: ...essage part with information about current message dev name and version of the device firmware IMEI LTE modem identifier IMSI ICCID SIM card SIM chip identifiers num the number of the message UTC the...

Page 22: ...ta slice 0 logic zero input 1 logic one input s_alarm2 state of ALARM2 input at the time of data slice 0 logic zero input 1 logic one input s_magnet the presence of an external magnetic field at the t...

Page 23: ...rver to device packet 0x03 Device to server packet Send data from the port RS485 RS232 S 0x0B Identity packet includes IMEI and ICCID Modem sends this packet to the server when communication session i...

Page 24: ...10 2 Data length 1 1024 12 1 1024 Data Packet example 05040C00EEAAD00700000400FF1122FF Transparent packet ID Packet type Packet size Packet ID Timeout Data length Data send to the device 0x05 0x04 0x...

Page 25: ...PORTATION REQUIREMENTS Vega NB 13 modem shall be stored in the original packaging in heated room at temperatures 5 to 40 and relative humidity less than 85 The modem shall be transported in covered fr...

Page 26: ...Vega NB 13 User Manual 26 Revision 06 of 24 January 2022 6 CONTENT OF THE PACKAGE The modem is delivered complete with Vega NB 13 modem 1 pc Antenna 1 pc Factory certificate 1 pc...

Page 27: ...te does not have an TCD stamp and or there is no sticker with information about the device the serial number DevEUI EMEI printed on the product differs from the serial number DevEUI EMEI specified in...

Page 28: ...Date Name Comments 01 30 10 2019 KEV The first release 02 20 01 2020 KEV Description of operation modes is added communication protocol is added 03 12 05 2020 KEV Communication and data collection al...

Page 29: ...Vega NB 13 User Manual 29 Revision 06 of 24 January 2022 vega absolute ru User Manual Vega Absolute OOO 2019 2022...

Reviews: