background image

 

 

 

 

 

 

 

 

 

 

 

 

 

GNSS BEACON 

VEGA M200, M210, M300, M310 

 
 

User Manual 

 

 

 

 

Summary of Contents for M-300

Page 1: ...GNSS BEACON VEGA M200 M210 M300 M310 User Manual ...

Page 2: ...GE 7 Activation 7 Operation modes 9 Work with radio tags 10 Work with wireless relay 12 Protection methods 14 Settings 15 Parameters for work with WIALON 18 Indication 19 SMS commands 20 Work with the Web site 21 Configurator 21 4 TRANSPORTATION AND STORAGE REQUIREMENTS 22 5 COMPLETE SET 23 6 WARRANTY 24 APPENDIX 25 EXAMPLES OF SMS MESSAGES SENT BY THE DEVICE 25 ...

Page 3: ...d provides information on powering and activation procedure control commands and functions of the device Beacons of M200 and M300 series are different only in content of the package Every of them has an optional variant of delivery in hermetic case Vega M210 and Vega M310 Work with the device does not require special training or professional skills This user manual contains all necessary informati...

Page 4: ...torcycles bicycles boats etc Animals pets domestic and breed animals etc Construction machinery cranes trucks etc Containers coaches and wagons baggage suitcases etc The GNSS beacon is able of long off line operation with high level of security does not require external connections Being in sleep mode most of time the device is difficult to detect visually or with radio scanners The device sends i...

Page 5: ...Vega M200 M210 M300 M310 User Manual 5 Revision 03 of 05 08 2022 Figure 2 Physical form and content of the package of Vega M300 left figure and Vega M310 right figure ...

Page 6: ...nal temperatures С 40 85 Off line operation 2 years The GNSS beacon has the following functions Parameter setting through SMS messages and personal page at the web site vega m com Customizable notifications of the object start moving or cross the specified geofence borders Accurate positioning of the object Automatic clock adjustment according to GPS GLONASS satellites Automatic balance control of...

Page 7: ...SM network After registration in the GSM network the indicator starts frequently flashing the device is ready for activation STEP 3 There are three ways to activate the device 1 Call the SIM card number of the device The device hangs up the incoming call and remembers the phone number from which the call has been made as the owner s phone number This method is only possible if the device SIM card ...

Page 8: ...ce is activated in a room bring it to the window Every time the device identifies its coordinates it also identifies the current time and adjusts its internal clock through satellites Time setting takes the time zone into account which is set by the parameter P The default parameter is 03 which means 3 hours to GMT STEP 5 After identifying the coordinates the device registers again in the network ...

Page 9: ...uring the main session parameter 24 see table 1 During additional communication sessions parameter 12 see table 1 the device switches on only for receiving possible SMS commands and synchronizing with the server You can obtain the coordinates in the intermediate session by sending an SMS command with the text 500 or 09 to the device If the command is sent from the unknown number add the device PIN...

Page 10: ...he device phone number after that the device switches into radio tags addition mode Indication will be as frequent flashing and the message will come to the owner s phone number Insert the battery in radio tag STEP 3 The device searches around the radio tags during 5 minutes At that time you should to insert the battery in the radio tag The message will come to the owner s phone number Radio tag N...

Page 11: ...the radio tags from the device memory you should to send the SMS command 001 from the owner s phone number To OFF the radio tags search you should to send the SMS command 002 from the owner s phone number To ON the radio tags search you should to send the SMS command 003 from the owner s phone number ...

Page 12: ...you should to supply reverse polarity power 12V on the relay plus on black wire minus on the red If you do it all right then relay makes triple sound and it means that relay has erased RELAY CONTROL To delete all radio tags and relay from the device memory you should to send the SMS command 000 from the owner s phone number Forced relay blocking is made by SMS command 007 or 666 from the owner s p...

Page 13: ...e relay in an important circuit of which breaking will entail vehicle stopping Relay has four wires red power 12V it is recommended to connect the power such way as power appears when engine ON black ground brown two normally closed contacts which must be connected at the breaking circuit for example circuit of gasoline pump power see figure 3 Current carrying capacity of the relay 9А Figure 3 Sch...

Page 14: ...sor for several hours by pressing the combination of keys X where X is a digit from 1 to 9 For example if you want to turn off the sensor for 6 hours press 6 after alarm announcement If the owner s phone is unavailable or the owner does not answer the call within 30 seconds the device sends an SMS with the text Motion sensor has triggered 2 Then the device identifies and sends its coordinates to t...

Page 15: ...ice sends a message Balance Value by default 50 SMS command PIN 58 XXX Example Threshold setting 100 1234 58 100 59 The balance request code Detected automatically if the SIM card is of MTS Beeline Megaphone or Tele2 cell operator SMS command PIN 59 XXX Example Balance request code setting 111 1234 59 111 24 Main session time by default random value SMS command PIN 24 hhmm Example Main session tim...

Page 16: ... PIN 38 X or 38X where X 0 1 0 OFF 1 continuously ON Example Sensor ON 1234 38 1 или 381 60 Automatically relay blocking ON OFF 0 by default SMS command PIN 60 X where Х 0 1 0 wireless relay do not blocked automatically 1 wireless relay is blocked automatically Example Automatically blocking ON 1234 64 1 47 Ignoring time of the motion sensor triggering by default 5 SMS command PIN 47 X where X 5 9...

Page 17: ...1234 S 1 The following settings are designated only by the experienced users IP Setting of the IP address and server port where the data from the device are sent SMS command PIN IP xxx xxx xxx xxx yyyyy Example Set IP 123 123 123 123 and port 55555 1234 ip 123 123 123 123 55555 T Motion sensor sensitivity per amplitude SMS command PIN T xx where x 0 40 Example Sensitivity per effect amplitude 15 1...

Page 18: ...X Example Data transfer by WIALON protocol ON 1234 w 1 wip Setting of IP address and WIALON server port SMS command PIN wip XXX XXX XXX XXX YYYYY Example IP Setting 185 213 0 24 and port 20332 of the Gurtam server 1234 wip 185 213 0 24 20332 IP Setting 95 163 120 190 and port 20213 of the Gelios server 1234 wip 95 163 120 190 20213 wdp The device password setting for Gurtam server access for Gelio...

Page 19: ...ent flashings Waiting for an incoming call or SMS while the device is activated Double flashings every 3 seconds Registration in the GSM network Flashings every 3 seconds Coordinates search GPS GLONASS runs Triple flashings every 3 seconds The device is activated waiting for SMS commands One short one long flashing GPRS runs Flashing every 8 seconds Error Two long and three short flashings USB run...

Page 20: ...one number XXXX09 from the unknown number Send the coordinates and the device status in the form of Internet link 380 from the owner s phone number XXXX380 from the unknown number Motion sensor OFF 381 from the owner s phone number XXXX381 from the unknown number Protection ON with motion sensor Motion sensor continuously works 000 from the owner s phone number XXXX000 from the unknown number Dele...

Page 21: ...n Where is the Beacon and entering the IMEI number of the device and the password from the label on the device CONFIGURATOR You can configure and manage the device parameters as well as update the firmware using the M200 M210 M300 M310 Configurator program Connection to the device through the Configurator program is carried out automatically when the device is connected to the computer via USB and...

Page 22: ...n its original packaging in heated room at temperatures 5 С to 40 С and relative humidity less than 85 The GNSS beacon shall be transported in covered freight compartments of all types at any distance at temperatures 40 C to 85 C If the device is transported at temperatures below zero hold it at room temperature for 24 hours before operation ...

Page 23: ...ete with 1 GNSS beacon with 3 neodymium magnets 1 pc 2 RF tag 1 pc 3 Battery for RF tag 1 pc 4 Factory certificate 1 pc The Vega M300 GNSS beacon is delivered complete with 1 GNSS beacon 1 pc 2 RF tag 1 pc 3 Battery for RF tag 1 pc 4 Wireless relay 1 pc 5 Double sided red tape 1 pc 6 Factory certificate 1 pc The Vega M310 GNSS beacon is delivered complete with 1 GNSS beacon with 3 neodymium magnet...

Page 24: ...cate the factory certificate does not have an TCD stamp and or there is no sticker with information about the device the serial number DevEUI EMEI printed on the product differs from the serial number DevEUI EMEI specified in the factory certificate the product has been subject to alterations in the design and or software which are not provided for in the operational documentation the product has ...

Page 25: ... Balance threshold is 50 59 102 Balance request code is 102 24 1200 Main session time is 12 00 P 06 The device time zone is 6 00 3 Coordinates form in SMS is Internet link 12 3 Device is ON 3 times per day 03 0 Language is Russian 38 1 Motion sensor is always ON 20 2300 0700 1000 1700 Guarding periods are 23 00 7 00 and 10 00 17 00 47 5 Ignoring time of motion sensor after triggering is 5 minutes ...

Page 26: ...er B 1 Bootloader version is 1 IMEI xxxxxxxxxxxxx IMEI number of the device 3 EXAMPLE OF AN SMS MESSAGE WITH SETTINGS THROUGH WIALON IPS 2 0 PROTOCOL EXPLANATION WIALON 1 Work with WIALON IPS 2 0 is ON IP 193 193 165 165 20332 IP address of additional server Password 12345 Password for access to server when it is necessary 4 EXAMPLE OF AN SMS MESSAGE WITH COORDINATES AND DEVICE STATUS IN THE TEXT ...

Page 27: ...n 03 of 05 08 2022 A 123 Motion amplitude T 25 Ambient temperature A h 40 Battery charge 12 1 The device switches from the sleep mode once 1 per day 4 4 GSM signal has MAX level Bal 235 Balance MCC 250 Etc GSM base station parameters MCC MNC LAC CID ...

Page 28: ...lation from Russian Document number В 01М200 01 Revision and date 03 of 05 08 2022 Revision History Date Name Comments 01 11 10 2017 KEV Manual is ready for printing 02 24 09 2018 KEV Functions are corrected removed 112 03 05 08 2022 KEV Scheduled revision service center address has been changed ...

Page 29: ...Vega M200 M210 M300 M310 User Manual 29 Revision 03 of 05 08 2022 vega absolute ru User Manual ООО Vega Absolute 2017 2022 ...

Reviews: