DOC. NO. 5956.6K6.00
P. 21 / 28
10.2 PROGRAMMING SHEETS
WARNING:
To set the board parameters, carefully follow the order given in this programming file, from point 1 to
point 7.
WARNING:
When modifying parameter
, all the parameters (except those belonging to the
family)
assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of
the
family are not modified.
VDU30
PROG 149
1. Switch OFF and then switch ON the machine.
2.
Enter into CFG parameter family and set the following parameters.
Hood Type like working cycles.
Atmospheric boiler.
Front loading door type.
Default values for Undercounter models.
SOFT START ENABLED.
Tank heater works only if boiler temperature reached.
Enable filling tank by means of rinsing cycles.
Detergent level switches not enabled.
Select user interface under counter model.
Regeneration cycle disabled.
ALARMS ENABLED.
3. Switch OFF and then switch ON the machine.
4. Modify Factory parameters:
Enter into FAC parameter family.
Boiler Temperature Threshold.
Boiler Temperature Adjust.
During stand-by boiler is kept at lower temperature than Temperature Threshold.
Tank Temperature Threshold.
HISTERESIS of Tank Temperature.
5. Modify the cycle parameters:
Cycle 1 parameters family.
Long Wash Phase [min]
Short Wash Phase [s]
Pause [s]
Rinse Phase Duration [s]
Final Pause [s]
Cycle 2 parameters family..
Long Wash Phase [min]
Short Wash Phase [s]
Pause [s]
Rinse Phase Duration [s]
Final Pause [s]
Set other parameters.
Fahrenheit
6. Switch OFF and then switch ON the machine.
7. Modify Detergent dosage:
Enter into GEn parameter family.
Detergent Dosage During Cycle Execution (during wash phase)
Rinse Aid Dosage During Cycle Execution (when refilling boiler)
8. Switch OFF and then switch ON the machine.