DOC. NO. 5956.6K6.00
P. 13 / 28
8 OTHER PARAMETERS
8.1
Dishwashing Parameters
Sym.
Parameter Description
Unit
Min
Max
Factory
Default
Initial Pause before start washing (for ALL cycles)
[s]
0
10
0
Delay for the 2
nd
wash pump (PW only)
[s]
0
10
3
Active a drain phase at the end of washing phase.
[s]
0
40
0
Duration of pause after rinse cycle (valid for dishwashers with
door/hood lock device) [See par. 9.1 DETERGENT AND RINSE
AID LEVEL SENSORS ACTIVATION].
[s]
0
60
0
Celsius/Fahrenheit selection
0 = Celsius
1 = Fahrenheit
-
0
1
1
Rinse Temperature Display.
Enable rinse temperature probe (if installed).
0 = during rinse phase the display shows boiler temperature;
1 = during rinse phase the display shows rinse temperature;
-
0
1
0
Pulse Per Litre.
This parameter must be settled in according to flow meter
installed [present up to software version 3.12].
[p/l]
0
255
0
Number of wash cycles performable without detergent (only for
dishwashers with external detergent level sensor – par. 9.1
DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION)
[
]
-
0
5
5
Enable mode Thermal Label: if set to 1 it enables the mode and
disables the "endless cycle" button
-
0
1
0
Boiler temperature in mode Thermal Label.
[°F]
113
206
186
Tank temperature in mode Thermal Label.
[°F]
104
194
167
Tank temperature hysteresis in mode Thermal Label.
[°F]
32
86
35