System Setup Screens
[254, 257-258] Temperature Setup Screen
43
[254, 257-258] Temperature Setup Screen
Legend for numbered boxes
01-01-2000
12:00 AM
ALL FUNCTIONS NORMAL
1
2
[257]
[258]
59 F
3
[254]
TC DENSITY
NO
This screen displays the Temperature Compensation Setup
Screen.
1
TC Reference [257]- touch the Down Arrow button to the
right of the window and enter a desired Temperature
Compensation reference temperature. The allowable range
is -49 to +120°F (-45 to +48.9°C). The default is 59°F
(15°C).
2
Print TC Volume [258] - touch the Down Arrow button to
the right of the window and select: Yes or No (default).
When set to NO, TC Volumes are not reported in displays,
printouts, and serial reports.
3
TC Density [254] - touch the Down Arrow button to the
right of the window and select: Yes or No (default).
When set to Yes, all the inventory/delivery screens,
printout and RS-232 commands will display density
values as temperature compensated and this will be
indicated by “TC”.