background image

Installation of Upgrade Kit

Safety Precautions

6

Figure 4.   Attaching the new CPU board/inner door assembly to the console

983-4.eps

1

1

2

3

1

Get the new TLS2P CPU board/inner door a

ss

embly 

from the kit. Get the two T-15 torx 

s

houlder 

s

crew

s

 

you removed from the right 

s

ide of the door earlier.

2

Get the static protecting wrist strap from the kit and slip 
the looped end around one wrist and connect the other 
end to side of the console.

3

Remove the CPU board/inner door assembly from its 
packing and push the ground cable and ribbon cable 
through the right side opening in the inner door 
assembly and place the inner door assembly on the 
console and screw in the two right-side T-15 torx 
shoulder screws (item 1 

in Figure 4

), snug but not tight. 

Reattach the grounding strap to the bare metal on the 
top of the inner door.

4

Loosen the ground wire saddle clamp on the inner door 
(item 2 

in Figure 4

) and loop the ground wire through it 

and tighten securely (see photo at right). The other end 
of the ground wire will attach to the new door’s 
grounding saddle clamp.

5

Connect the ribbon cable (item 3 

in Figure 4

) to the 

connector on the left side of the new CPU board.

Summary of Contents for TLS2

Page 1: ...Manual No 577013 983 Revision B Upgrade Guide TLS2 to TLS2P...

Page 2: ...r Terms and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Contact Veeder Root Customer Service at 800 873 3313 with the specific part numbers and quantities that were missing or received damaged 2 Fax...

Page 3: ...kit 3 Procedure 3 Figures Figure 1 Removing TLS2 Console Door 3 Figure 2 Disconnecting the display assembly from the CPU board 4 Figure 3 Removing the display 5 Figure 4 Attaching the new CPU board in...

Page 4: ...por polisher installation wireless equipment installation tank and line preparation and line leak detector installation TLS 350 Technician Level 2 3 or 4 Certification Contractors holding valid TLS 35...

Page 5: ...id damage to equipment property envi ronment or personal injury STATIC SENSITIVE COMPO NENTS Wear grounded anti static wrist strap before handling the printed circuit board READ ALL RELATED MANUALS Kn...

Page 6: ...rs to fit T 10 and T 15 screws PROCEDURE Figure 1 Removing TLS2 Console Door 983 1 eps 2 3 1 1 2 Shut off tag and lockout power to the TLS2 Console 1 Remove and retain the top and bottom T 15 shoulder...

Page 7: ...1 Remove and retain the four T 10 screws spacers and washers items1 and 2 in Figure 2 attaching the display to the CPU board Retain the two shorter screws 0 5 long item 2 in Figure 2 and all of the wa...

Page 8: ...d wire saddle clamp on the inner door item 3 in Figure 3 3 Remove the ribbon cable from its connector on the edge of the CPU board item 4 in Figure 3 Notice the orientation of the ribbon cable in the...

Page 9: ...from its packing and push the ground cable and ribbon cable through the right side opening in the inner door assembly and place the inner door assembly on the console and screw in the two right side...

Page 10: ...rd items 1 and 2 in Figure 2 2 Get the display and attach its 2 wire cable plug to the connector on the CPU board item 1 in Figure 5 3 Push the display s ribbon cable into its connector on the CPU boa...

Page 11: ...T 15 torx shoulder screws and the new TLS2P door 2 Position the door over the left holes in the top and bottom of the console and screw in the two shoulder screws item 1 in Figure 6 3 Loosen the groun...

Page 12: ...ic preventing grounding strap from the inner door Remove the two right T 15 torx screws holding on the inner door item 1 Figure 6 close the new outer door reinsert the two shoulder screws in the two h...

Page 13: ...For technical support sales or other assistance please visit www veeder com...

Reviews: