TLS-450 Setup and Operation Screens Manual
243
Tank Test Diagnostics - SLD In-Progress
The SLD In-Progress report will display any SLD tests that are currently active, or in-progress. This
screen will be refreshed every 30 seconds.
The Status field will indicate if a SLD test is not active for the currently selected tank(s). All field values
are displayed after the first period of the test (15 minutes for gross tests or 30 minutes for precision
tests).
Tanks must have SLD enabled and be configured with a probe that supports leak detection to be visible
in this report.
Report Column Descriptions
Status
If there is no active SLD test, Off will be displayed in the data view for the selected tank. The status field
shows Off if the test is completed (shows result of last test), else if test is active, the status field shows
On.
Value range: Status of tanks under test, e.g., T 1: ON, T 2: OFF