Display Replacement Procedure

Before You Begin

4

2.

Notice the two small slots in the top of the display/keyboard door.

3.

Facing the inside of the display door, insert a flat blade screwdriver between the top of the plastic display/
keyboard cover and next to one of the two tabs of the cover that seat in the door’s slots (see Figure 2). Gently 
pry down with the screwdriver blade near the tab to free it from the slot in the door, then repeat this procedure 
to free the second tab. Firmly rotate the cover away from the door to free its bottom tabs from the bottom door 
slots. Feed the two cables between the door(s) and remove the cover from the console and set it aside.

Figure 2.   Top Display/Keyboard Cover Securing Tabs

4.

Get the new display/cover assembly from kit. Get the two blank wiring input labels from the kit, P/N 330636-
000 for a TLS-300 or EMC console, or P/N 330617-000 for a TLS-350 Series, EMC, ProMax or ProPlus 
console.

5.

Remove the backing from the Power Area input label and press it into the left partition (1)on the back of the 
cover. Remove the backing from the Intrinsically-Safe Area input label and press it into the right partition (2) on 
the back of the cover (see Figure 3).

Figure 3.   Display/Keyboard Cover Wiring Input Label Positions (330636-000 Labels Shown)

6.

With the old and new display/keyboard covers side by side, copy the wiring input notations from the old 
display/keyboard cover labels onto the new cover’s wiring input labels. 

Be especially careful to accurately 

copy the wiring input notations from the old display/keyboard cover to the replacement cover!

1

2

Summary of Contents for TLS-3 Series

Page 1: ...TLS 3XX Series Consoles Manual No 577014 101 Revision A Display Replacement Guide...

Page 2: ...r Terms and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Contact Veeder Root Customer Service at 800 873 3313 with the specific part numbers and quantities that were missing or received damaged 2 Fax...

Page 3: ...Figures Figure 1 Removing the Display and Keyboard Cable Connectors 3 Figure 2 Top Display Keyboard Cover Securing Tabs 4 Figure 3 Display Keyboard Cover Wiring Input Label Positions 330636 000 Label...

Page 4: ...addition Contractors with the following sub certification designations are approved to perform installation checkout startup programming system tests troubleshooting service techniques and operations...

Page 5: ...0 Series EMC ProMax And Proplus Consoles Wiring Input Labels 1 set 4 330636 000 TLS 300 Series And EMC Basic Consoles Wiring Input Labels 1 set 5 577014 101 Manual 1 GROUND AC POWER L1 G N Connected t...

Page 6: ...of the console Disconnect the Display 1 upper and Keyboard 2 lower cable connectors from the consoles CPU board as shown in Figure 1 Figure 1 Removing the Display and Keyboard Cable Connectors TLS 300...

Page 7: ...oard Cover Securing Tabs 4 Get the new display cover assembly from kit Get the two blank wiring input labels from the kit P N 330636 000 for a TLS 300 or EMC console or P N 330617 000 for a TLS 350 Se...

Page 8: ...the two along its top edge and that there are also two slots in the bottom as well as the top flange of the console s right door 10 With the keypad and display facing the inside of the console right d...

Page 9: ...For technical support sales or other assistance please visit www veeder com...

Reviews: