  Introduction

This manual contains instructions for replacing the right front door LCD display in the following consoles:

• TLS-300 (all versions)

• TLS-350 (all versions)

• EMC (all versions)

• ProPlus and ProMax 

Contractor Certification Requirements

Veeder-Root requires the following minimum training certifications for contractors who will install and setup the 
equipment discussed in this manual:

Installer Certification (Level 1):

 Contractors holding valid Installer Certification are approved to perform wiring 

and conduit routing; equipment mounting; probe, sensor and carbon canister vapor polisher installation; wireless 
equipment installation; tank and line preparation; and line leak detector installation.

Technician Certification (Level 2/3):

 Contractors holding valid Technician Certifications are approved to 

perform installation checkout, startup, programming and operations training, system tests, troubleshooting and 
servicing for all Veeder-Root Series Tank Monitoring Systems, including Line Leak Detection. In addition, 
Contractors with the following sub-certification designations are approved to perform installation checkout, startup, 
programming, system tests, troubleshooting, service techniques and operations training on the designated system. 

• Wireless 2
• Tall Tank

VR Vapor Products Certification:

 Contractors holding a certification with the following designations are 

approved to perform installation checkout, startup, programming, system tests, troubleshooting, service techniques 
and operations training on the designated system. 

• ISD – In Station Diagnostics
• PMC – Pressure Management Control
• CCVP - Veeder-Root Vapor Polisher
• Wireless – ISD/PMC Wireless
• A current Veeder-Root Technician Certification is a prerequisite for the VR Vapor Products course. 

Warranty Registrations

 may only be submitted by selected Distributors.

Safety Precautions

The following safety symbols may be used throughout this manual to alert you to important safety hazards and 
precautions.

ELECTRICITY
High voltage exists in, and is supplied to, 
the device. A potential shock hazard exists.

TURN POWER OFF
Live power to a device creates a potential shock 
hazard. Turn Off power to the device and associ-
ated accessories when servicing the unit.

OFF

Summary of Contents for TLS-3 Series

Page 1: ...TLS 3XX Series Consoles Manual No 577014 101 Revision A Display Replacement Guide...

Page 2: ...r Terms and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Contact Veeder Root Customer Service at 800 873 3313 with the specific part numbers and quantities that were missing or received damaged 2 Fax...

Page 3: ...Figures Figure 1 Removing the Display and Keyboard Cable Connectors 3 Figure 2 Top Display Keyboard Cover Securing Tabs 4 Figure 3 Display Keyboard Cover Wiring Input Label Positions 330636 000 Label...

Page 4: ...addition Contractors with the following sub certification designations are approved to perform installation checkout startup programming system tests troubleshooting service techniques and operations...

Page 5: ...0 Series EMC ProMax And Proplus Consoles Wiring Input Labels 1 set 4 330636 000 TLS 300 Series And EMC Basic Consoles Wiring Input Labels 1 set 5 577014 101 Manual 1 GROUND AC POWER L1 G N Connected t...

Page 6: ...of the console Disconnect the Display 1 upper and Keyboard 2 lower cable connectors from the consoles CPU board as shown in Figure 1 Figure 1 Removing the Display and Keyboard Cable Connectors TLS 300...

Page 7: ...oard Cover Securing Tabs 4 Get the new display cover assembly from kit Get the two blank wiring input labels from the kit P N 330636 000 for a TLS 300 or EMC console or P N 330617 000 for a TLS 350 Se...

Page 8: ...the two along its top edge and that there are also two slots in the bottom as well as the top flange of the console s right door 10 With the keypad and display facing the inside of the console right d...

Page 9: ...For technical support sales or other assistance please visit www veeder com...

Reviews: