O P E R A T I O N

OPERATION MODE

CHANGING A PRESET VALUE

PGM

PGM

PGM

Default display is the present count
value.

Pressing the Program Key will cause the
display description to appear on the
main display.*  If there is no key activity
for 3 seconds, the primary display will
switch back to the count value.

Continued pressing of the Program Key
will scroll through the Presets.  (See
Parameter Sequence below.)  The full
parameter description will appear on the
main display.*

To change a Preset value, press the
Scroll Key.  If there was no key activity
for 3 seconds, the Preset value will
appear (one digit description shown on
secondary display); however, press the
Scroll Key in order to edit.   The unit will
now be in Edit Operation as signified by
the most significant digit flashing.**

Use the Scroll Key to move from left to
right and highlight the digit that needs
to be changed.  Wrap around will occur
from the least significant to the most
significant digit.

Use the Down Key to decrement the
digit until the desired value appears.
The display will wrap around from 0 to
9.

After the desired digits have been
changed, press the Program Key to enter
the new value.  The new value will
appear on the main display without any
flashing digits.  Press the Progam Key
again and the parameter description will
appear on the main display.

23456

PSEt

Count

P

34567

P

34567

P

33567

PSEt

PGM

* Parameter descriptions will not
appear on the primary display if the
"Help" function has been disabled.

** Edit Operation cannot be
accessed if the Preset Lock has
been enabled in Program Mode.

PARAMETER SEQUENCE

C o u n t

Count

Function:  Displays present count value

Range:  0 to 99999

PGM

Preset

Function:  Defines the value at which
Output 1 will activate

Adjustment Range:  0 to 99999

Default Value:  10

PGM

P S E t

P

Batch Preset

Function:  Defines the  batch preset
value at which Output 2 will activate

Adjustment Range:  0 to 99999

Default Value:  10

PGM

Background Total

Function:  Displays present background
total (continuous count value
irrespective of present count value)

Range:  0 to 99999

b G t o t

t

b P r t

r

Batch Value

Function:  Displays present batch value
(# of times preset is reached)

Range:  0 to 99999

PGM

b A t c h

b

Summary of Contents for Series C628

Page 1: ...day to day operation and allows editing of presetvalues TheProgramModeenablestheconfigurationofvariousparametersprior toinitialoperation Theseparametersincludethoseforbasicconfigurationaswellas others...

Page 2: ...wn to the left and push it forward until it is firmly in contact with the rear face of the mounting panel and the tabs on the bracket arm are seated in the mounting grooves on the side of the unit The...

Page 3: ...inals 10 11 12 15 are not used units The neutral side for AC powered units and the negative side for DCpoweredunitsareconnectedtoTerminal 14 Transistor Outputs Your unit comes standard with 2 NPN outp...

Page 4: ...the preset in countdownoperation Parametermustbedisplayed to be reset This button can be disabled via the Front PanelResetEnable parameterinProgramMode InProgramMode No function In All modes Will abo...

Page 5: ...ccur from the least significant to the most significantdigit Use the Down Key to decrement the digituntilthedesiredvalueappears The display will wrap around from 0 to 9 Afterthedesireddigitshavebeen c...

Page 6: ...s the scroll key to enterEditOperation MSDflashing Use the scroll and edit buttons to change the valueasinOperationMode describedon page 5 Press the Program Key to enter any changes Successivepresseso...

Page 7: ...ge u P _ A r d n _ A r Up The unit will count up from zero and activate theoutput s whenthe preset s isreached Up with Auto Reset The unit will count up from zeroandactivatethe output s whenthepreset...

Page 8: ...ronicinputs andencoders DefaultValue 10000 PGM 1 Output 1 Time Function Sets the amount of time output 1 will be active once Preset 1 is reached AdjustmentRange 00 00 Latched to99 99 DefaultValue 1 00...

Page 9: ...t Range 1 to 99 Default Value 1 A d d r PGM b b A u d Baud Rate Appears only if communication board is installed and activated Function Selectstheserialcommunicationspeed AdjustmentRange 1 2 0 0 2 4 0...

Page 10: ...Determineswhetherthemulti characterparameternamewillappearonthemaindisplayfor3 secondspriortotheparametervalueappearing AdjustmentRange H E L P h Help Yes Multi characterparameter descriptionswillapp...

Page 11: ...1993 Communication Type Serial asynchronous UART to UART Data Format Open ASCII One start bit even parity seven data bits one stop bit Physical Layer RS 485 Maximum Zones 99 Baud Rate Selectable from...

Page 12: ...hich theCompanyconsentstohavereturnedshallbeshippedF O B the Company s factory TheCompanycannotassumeresponsibilityor acceptinvoicesforunauthorizedrepairstoitscomponents eventhough defective The life...

Reviews: