O P E R A T I O N
OPERATION MODE
CHANGING A PRESET VALUE
PGM
PGM
PGM
Default display is the present count
value.
Pressing the Program Key will cause the
display description to appear on the
main display.* If there is no key activity
for 3 seconds, the primary display will
switch back to the count value.
Continued pressing of the Program Key
will scroll through the Presets. (See
Parameter Sequence below.) The full
parameter description will appear on the
main display.*
To change a Preset value, press the
Scroll Key. If there was no key activity
for 3 seconds, the Preset value will
appear (one digit description shown on
secondary display); however, press the
Scroll Key in order to edit. The unit will
now be in Edit Operation as signified by
the most significant digit flashing.**
Use the Scroll Key to move from left to
right and highlight the digit that needs
to be changed. Wrap around will occur
from the least significant to the most
significant digit.
Use the Down Key to decrement the
digit until the desired value appears.
The display will wrap around from 0 to
9.
After the desired digits have been
changed, press the Program Key to enter
the new value. The new value will
appear on the main display without any
flashing digits. Press the Progam Key
again and the parameter description will
appear on the main display.
23456
PSEt
Count
P
34567
P
34567
P
33567
PSEt
PGM
* Parameter descriptions will not
appear on the primary display if the
"Help" function has been disabled.
** Edit Operation cannot be
accessed if the Preset Lock has
been enabled in Program Mode.
PARAMETER SEQUENCE
C o u n t
Count
Function: Displays present count value
Range: 0 to 99999
PGM
Preset
Function: Defines the value at which
Output 1 will activate
Adjustment Range: 0 to 99999
Default Value: 10
PGM
P S E t
P
Batch Preset
Function: Defines the batch preset
value at which Output 2 will activate
Adjustment Range: 0 to 99999
Default Value: 10
PGM
Background Total
Function: Displays present background
total (continuous count value
irrespective of present count value)
Range: 0 to 99999
b G t o t
t
b P r t
r
Batch Value
Function: Displays present batch value
(# of times preset is reached)
Range: 0 to 99999
PGM
b A t c h
b