SWR-584C Instruction Manual 

HF/VHF/220MHz SWR Analyzer 

 

1.0 Introduction 

 
The SWR-584C is a compact battery-powered RF-impedance analyzer that covers 0.53-230 
MHz in nine overlapping bands. Fully portable and self contained, it delivers a wide range of 
basic and advanced RF measurements to present a complete picture of your antenna systems 
and networks. It also measures capacitance, inductance, and serves as a discrete signal 
generator and frequency counter for the test bench. The SWR-584C is the latest entry in a 
long line of time-tested designs using proven technology and rugged construction to ensure 
years of reliable service. Please read through this manual carefully before powering up your 
analyzer for the first time. The manual contains 

important safety information

 you'll need to 

know to avoid damaging your unit. There's also valuable operating instruction to help you to 
take advantage of its full range of functions and features right away.  

 
1.1 SWR-584C Control Layout 

   

                   

155-230

113-155

67-113

28-67

11-28

4.7-11

2.1-4.7 1.0-2.1

0.53-1.0

Lower

Range

TUNE

FREQUENCY MHz

POWER

GATE

MODE

SWR

IMPEDANCE

MFJ HF/VHF SWR ANALYZER

MODEL MFJ-259C

ANTENNA

GROUND

FREQUENCY

COUNTER

INPUT

POWER

13.8 VDC

MFJ

POST

1

2

3

4

5

6

7

8

9

10

11

12

 

 

1. Antenna Port:

 SO-239 for attaching antennas and RF devices under test. 

2. Ground Post:

 Binding post for attaching leads to chassis ground. 

3. Counter Input:

 BNC-female input jack for analyzer's 

Frequency Counter

 function. 

4. External Power: 

2.1-mm power jack accepts power adapter or supply (13.8V + center pin). 

5. Power Switch:

 Applies power from internal batteries or external power source. 

6. LCD Display: 

Two-line digital display presents operating frequency and measured data. 

7. SWR Meter:

 Provides continuous analog readout of SWR measurements (Zo=50). 

8. Impedance Meter:

 Displays impedance magnitude or reactance measurements. 

9. Gate:

 Push button sets counter gate speed, performs other specified functions. 

10. Mode: 

Push button selects measurement mode, performs other specified functions.     

11. Tune: 

VFO capacitor, provides analog frequency control for the analyzer's generator. 

12. Frequency: 

High and low-range band switches select analyzer's operating range.

    

 

VECTRONICS 

HF/VHF/220MHz SWR Analyzer 

SWR-584C

Summary of Contents for SWR-584C

Page 1: ...SWR 584C Owner s Manual 300 Industrial Park Road Starkville MS 39759 662 323 5800 CAUTION Read All Instructions Before Operating Equipment HF VHF 220MHz SWR Analyzer VERSION A1...

Page 2: ...11 28 4 7 11 2 1 4 7 1 0 2 1 0 53 1 0 Lower Range TUNE FREQUENCY MHz POWER GATE MODE SWR IMPEDANCE MFJ HF VHF SWR ANALYZER MODEL MFJ 259C ANTENNA GROUND FREQUENCY COUNTER INPUT POWER 13 8 VDC MFJ POST...

Page 3: ...s and processes them into usable data 4 A LCD Display and two analog meters that present all computed data visually The processor also performs other mathematical calculations and conversions A D Conv...

Page 4: ...lly depending on the cable s electrical length and the severity of the load s mismatch referenced to 50 Ohms To collect meaningful impedance data for a device always connect the analyzer directly usin...

Page 5: ...vent leakage For rechargeable power NiCds work well but Ni MH cells have no charge memory hold a charge longer and offer greater storage capacity Before loading new cells always check or know the char...

Page 6: ...rs during a three minute interval the processor registers inactivity and switches into standby or Sleep mode A blinking SLP message on the display signals shutdown see below 2 6 Wake Up Cancel SLP To...

Page 7: ...8 67 11 28 4 7 11 2 1 4 7 1 0 2 1 0 53 1 0 Lower Range TUNE FREQUENCY MHz The VFO Tune capacitor features a reduction driver to provide smooth continuous frequency control with a small amount of overl...

Page 8: ...inductance 5 Frequency MHz Counter mode measures frequency of an external RF source Each menu selection opens with an Identifier Screen After a brief pause a Working Screen appears to present data Th...

Page 9: ...ne always remember the values for R X Z and are displaced values measured at the analyzer s calibration plane and do not represent the actual impedance of the device connected at the far end To read t...

Page 10: ...the Antenna jack Alternatively use the same lead length used in the actual circuit to incorporate stray lead inductance in your measurement Read Reactance Xc in Ohms on top line and Capacitance in pF...

Page 11: ...hms X at a given test frequency and computes inductance in uH To measure inductance Turn on the analyzer and allow it to boot to default mode R X Press Mode three times to access Inductance and wait f...

Page 12: ...uency Counter Mode This function makes the analyzer s frequency readout circuitry available as a discrete frequency counter for your test bench Like many counters sensitivity for locked up readings gr...

Page 13: ...e X 0 In addition it measures Impedance Magnitude Z as the primary display function eliminating the requirement to press and hold down the Gate switch when making those measurements Finally Advanced m...

Page 14: ...open the display will show a high impedance out of range message If a measurable load is connected to the Antenna jack the normal Z Mag data screen appears see below Advanced Identifier Z Mag default...

Page 15: ...eet At the far end of the cable open and shorted terminations yield the best accuracy resistive or reactive terminations can skew results or fail to test You may also test balanced line using this met...

Page 16: ...sonance is defined as the frequency where Capacitive Reactance Xc and Inductive Reactance XL cancel out and equal zero X 0 To access Resonance Mode Connect the DUT to the Antenna jack Enter Advanced M...

Page 17: ...ess Match Efficiency and wait for the working screen Note that if SWR exceeds the analyzer s 25 1 measurement limit this message appears Percentage of Reflected Power To calculate Percentage of Reflec...

Page 18: ...int along the way with little change It s normal to see a small SWR drop when adding cable or an increase when removing it because of resistive loss But if you see big SWR changes when altering feedli...

Page 19: ...shown below Length in Feet 468 Freq in MHz 1 85 Mhz 253 1 925 MHz 243 3 6 MHz 130 3 85 MHz 121 7 7 15 MHz 65 5 10 12 MHz 46 3 14 25 MHz 32 10 18 11 MHz 25 10 21 25 MHz 22 24 93 MHz 18 9 28 5 MHz 16 5...

Page 20: ...s long as the SWR remains below 2 1 As Section 6 1 pointed out your SWR shouldn t change even though the impedance may shift around because of phase rotation in the cable 6 3 Verticals 1 4 Wave Vertic...

Page 21: ...Velocity Factor Vf of an Unknown Cable Finding the Impedance Z of an unknown feedline or Beverage antenna Pre adjusting an antenna tuner Testing RF transformers and baluns for isolation Analyzing RF...

Page 22: ...he Electrical Length of your cable in feet Follow the DTF procedure Your cable s Electrical Length will be the DTF result without a Vf calculated in to the resut see below Label your result LEL for El...

Page 23: ...g these test coax may be piled or coiled on the floor but balanced lines must be isolated as described in Chapter 5 5 Connect Beverage antennas directly to the analyzer Intentional Mismatch Method To...

Page 24: ...orarily patched to the tuner s input using a short cable but many operators prefer to install a manual RF switch to facilitate rapid changeover If you choose to switch the analyzer confirm Your switch...

Page 25: ...igure A Measure SWR while connecting the grounded clip lead to points A B and C Current Balun A well designed current balun will exhibit low SWR over its entire operating range with the clip lead inst...

Page 26: ...pot where adding or subtracting even a tiny amount of capacitance will have the greatest effect To shift the resonance off the critical frequency or out of the band try removing turns to reduce capaci...

Page 27: ...out dated proof of purchase Any evidence of alteration erasure or forgery shall be cause to void any and all warranty terms immediately 2 VECTRONICS agrees to repair or replace at VECTRONICS option wi...

Page 28: ...is given in lieu of any other warranty expressed or implied 9 VECTRONICS reserves the right to make changes or improvements in design or manufacture without incurring any obligation to install such c...

Reviews: