closed position and via the PCM, push the two
gates into the fully closed position, but not
past.
SHORT STOP VALUE
The short stop distance can be set between 1mm
and 40mm of piston stroke.
PCM PUSH FORCE
The amount of force applied by the actuator when
in PCM can be set as a value from 1 to 15.
LEAF DELAY
Leaf delay is used in cases where one gate leaf
must move before the other. The most common
need for this arises when a mechanical 'lip' is fitted
to one of the gates. In a double leaf installation, a
leaf delay can be set whereby the M motor will
open before the S motor, and the S motor will close
before the M motor.
LEAF DELAY VALUE
The leaf delay is based on piston position, and can
be adjusted from 3-250mm of piston travel.
PRE-OPEN DELAY
Allows a delay between a valid trigger signal being
received and the gate commencing movement in
the opening direction. A warning light can be set to activate during this delay. (Refer to
Pre-flash modes of the feature PILLAR LIGHT, for more details) This setting applies to
both motors.
PRE-CLOSE DELAY
Allows a delay between a valid trigger signal being received and the gate commencing
movement in the closing direction. The delay will also occur if the gate is set to close
automatically. A warning light can be set to activate during this delay. (Refer to Pre-flash
modes of the feature PILLAR LIGHT, for more details). This setting applies to both
motors.
OPENING SPEED
Sets the maximum piston opening speed in millimeters per second . This setting applies
to both motors.
CLOSING SPEED
Sets the maximum piston closing speed in millimeters per second. This setting applies to
both motors.
RAMP UP DISTANCE
Sets the ramp-up distance in millimeters of travel of the piston when starting. This setting
applies to both motors.
If “Short Stop” is correctly set, PCM will cut off
when gates reach closed position, in line
Line of gates when closed
M gate closes
slightly behind
S Gate (Leaf delay)
S Gate closes first
Mechanical lip
1
*
M Gate continues to close
“Short Stop”
*
S Gate stops slightly before closed position
2
*
*
Mechanical lip on
M Gate engages with S Gate
With PCM, M Gate continues closing,
pushing the S Gate with it
3
4
Page 32
Page 33
open.
AUTO-CLOSE ON PARTLY OPEN
- will automatically close the gate if it is stopped while
opening, but before the reaching the fully opened position.
AUTO-CLOSE ON PARTLY CLOSED
- will automatically close the gate if it is stopped
while closing, but before reaching the fully closed position.
More than one advanced option can be selected.
MODES OF OPERATION - MENU 4
It is possible to select the following modes of operation: STANDARD, CONDOMINIUM and
REVERSING. All modes are triggered by closing a normally open contact between the TRG input
terminal and the COM terminal.
STANDARD MODE
- When stationary, a trigger impulse on TRG will cause the gate to
either open or close. On a moving gate, a trigger impulse on TRG will stop the gate. A
third impulse on TRG will cause the gate to reverse its direction of travel, i.e. the action is
START - STOP - REVERSE.
CONDOMINIUM MODE -
A trigger impulse on TRG will under all conditions open the
gate. If it were closing, it will stop and reverse to open. In this mode of operation, the only
way to close the gate is with the AUTO-CLOSE feature which is automatically activated
when CONDOMINIUM mode is selected.
REVERSING MODE -
A trigger impulse on TRG will reverse the direction of a moving
gate. If it were closing, it will stop and immediately begin opening. If it were opening, it
will stop and immediately begin closing.
RUN PROFILE – MENU 5
POSITIVE CLOSE MODE (PCM)
Setting positive close mode to ON will allow the gate to drive up hard to an end stop
without causing the collision circuitry to operate. This feature operates only during the last
few millimetres of piston travel in the closing mode.
POSITIVE CLOSE TYPE
PCM can be applied to one of the following:
?
Short Stop (further explanation follows)
?
M motor (MTRM)
?
S motor (MTRS)
?
Both M and S motors
SHORT STOP
PCM applied to one gate is ideal for securely locking two gates to each other without
having to fit end-stops. Typically, a 'mechanical' lip is fitted to one gate which will push up
against the other gate and via PCM keep pushing until the gates are mechanically locked.
To ensure that the gates do not close past their desired end point, the gate (S) against
which the gate (M) with the mechanical lip pushes, can be preset to stop slightly short of
its closed position. This is referred to as the 'Short Stop' distance. If the 'Short Stop'
distance is correctly set, the gate (M) will engage with the S gate sufficiently before the
AUTO-CLOSE ON OPEN
- will automatically close the gate if it has reached the fully