                                                                                                  User Manual 

 

 

  Page 

8

 of 27 

 

 

 

Gross Display 

gross 

weight 

 

Display data keep still 

 

zero, indicating zero weight 

Battery Using 

battery 

Hi Over 

Limit 

OK Within 

Limit 

Lo Below 

Limit 

Total Accumulation 

Count Counting 

function 

 
Key’s function   

    ON/OFF, EXIT AND SAVE SETTING 

  LEFT 

 RIGHT 

   DOWN 

      UP 

  CONFIRM, GO TO NEXT STEP 

 

Summary of Contents for VI 200

Page 1: ...Weighing Indicator User manual ...

Page 2: ...pect and fix the the weighing indicator is prohibited by Non professional staff WARNING Pls make sure the weighing display well earthing WARNING The indicator is electrostatic sensitive device pls power off during electrical connections internal components touched by hand is prohibited and please take the anti static measure ...

Page 3: ... Up and Low limit alarm 12 3 9 Print function 13 4 Calibration parameter setting 13 4 1 Enter calibration 13 4 2 Step of calibration operation 14 4 3 Application parameter setting 16 4 4 Communication setting 17 4 5 Application setting 18 4 6 Exit setting 20 5 Output data format 20 5 1 Computer continuous sending format 20 5 2 Big display continuous sending format 21 5 3 Serial interface reception...

Page 4: ...ower off automatically 1 2 Technical parameter Stimulating voltage 3 3 VDC A D converting speed 10 SPS Load signal range 0 12 8mV load capacity it can connect 4 pcs 350Ω load cell at most weight unit kg Resolution 3000e Interval 1 2 5 10 20 50 Display 6 digits LED LCD word height 20 3mm key ON OFF TOTAL HOLD TARE ZERO SET Interface RS232C Baud rate optional 1200 2400 4800 9600 ...

Page 5: ...User Manual Page 4 of 27 Operation temperature 10 40 Storage temperature 20 60 optional power 4V 4Ah rechargeable battery 110 220VAC 1 3 Outline and installation picture ...

Page 6: ...t turns green it means fully charged 5 If you don t use the battery long time take out the battery to protect the indicator from battery leakage 6 In order to keep the battery in best using condition it is suggest that you fully discharge the battery every month the method is that using the indicator till it is automatically power off 2 Installation and Calibration 2 1 connection indicator with lo...

Page 7: ...User Manual Page 6 of 27 Quick connector connection 2 2 communication interface PIN2 TXD 5 4 3 2 1 PIN3 RXD PIN5 GND 9 8 7 6 3 Basic operation 3 1 Key and display ...

Page 8: ...User Manual Page 7 of 27 Weighing indicator display instruction LED display instruction Weighing data display Kg Weight unit kg HOLD Hold the data Tare Display tare status Net Display net weight ...

Page 9: ...ht Display data keep still zero indicating zero weight Battery Using battery Hi Over Limit OK Within Limit Lo Below Limit Total Accumulation Count Counting function Key s function ON OFF EXIT AND SAVE SETTING LEFT RIGHT DOWN UP CONFIRM GO TO NEXT STEP ...

Page 10: ... on off enter and exit calibration ZERO Clear weight within zero range TARE 1 At Gross mode tare the loaded weight 2 At Net mode display gross weight after deduct tare HOLD Enter and exit hold mold TOTAL accumulating operation ON OFF Press it for 2 seconds to power on or power off ...

Page 11: ... stable zero is unworkable 3 4 TARE At the gross weight mode if the weight is stable pls press Tare key the indicator will take the loaded weight as tare and show net weight At this time the gross mode will change to net mode The net and tare light is on and the net weight is zero 3 5 HOLD C11 0 hold function unworkable C11 1 PEAK HOLD Press HOLD key the Hold light is on and show the Maximum data ...

Page 12: ...he indicator back to general weighing and the hold light is off C11 4 Special Animal weighing function Press Hold key the indicator will show LOC for 3 seconds the hold light is on During the 3 seconds the indicator will catch the average weight and show it Press HOLD key again to exit it 3 6 TOTAL Accumulation operation At Zero mode load weight till stable Press TOTAL key go to accumulating Mode ...

Page 13: ...Press TOTAL key the indicator show clrn it means don t clear the total Weight Press key confirm it and exit if clear total weight Press clrn change to clry it means clear total weight display Press to clear the the total weight and exit accumulating mode 3 7 10 times high resolutions Press SET and TARE key at the same time you will get 10 times high resolutions And it back to normal weighing after...

Page 14: ...nter it will be printed after press 1 second Note print the gross weight when at tare mode if the net weight is zero Can not print 4 Calibration parameter setting 4 1 Enter calibration There have two methods to enter the setting menu 1 when the switch CAL is off Press then press at the same time hold it you will enter C08 C39 setting 2 Take out the sealing screw on the back of indicator then press...

Page 15: ...libration operation According to the second method which can enter setting menu C01 C39 C01 UNIT C01 Press C1 1 unit is kg Press go to next step C02 Set decimal digits C02 Press option 0 1 2 3 4 C2 0 no decimal point C2 1 one decimal point C2 2 two decimal point C2 3 three decimal point Press go to next step C03 Division setting ...

Page 16: ... calibration zero 1 need calibration zero calibration zero please choose 1 and ensure scale is empty and stable light is on countdown CAL 10 CAL 0 then the indicator will show 0 00 example for two decimal point C06 Loading calibration C06 Press show C06 0 press change to C06 1 Press show SPAn Basic on max capacity setting add suitable weight on scale close to the max capacity heavier than 10 max a...

Page 17: ...rs C07 1 restore default parameters Note after the above parameters setting finish please do not set default parameters often avoid the original setting parameters lost 4 3 Application parameter setting C08 warning tone C8 1 open warning tone C8 0 close warning tone C09 Power off automatically C9 0 Non power off C9 10 keep still within 10 min power off automatically C9 30 keep still within 30 min ...

Page 18: ... hold C11 4 Animal weighing C12 Hold time if you choose C11 4 you can set the time C12 3 3 seconds C12 5 5 seconds C13 Upper limit alarm value C14 Low limit alarm value C15 Check inner code 4 4 Communication setting C18 Serial interface setting C18 0 No sending C18 1 Big display C18 2 Print format output C18 3 Command mode Z zero T tare R Reply weight C18 4 continuous sending C19 BAUD RATE C19 0 1...

Page 19: ...ually Zero range 10 Max capacity C20 20 Manually Zero range 20 Max capacity C20100 Manually Zero range 100 Max capacity C21 Initially zero C21 0 No initially zero C21 1 Initially zero range 1 Max capacity C21 2 Initially zero range 2 Max capacity C21 5 Initially zero range 5 Max capacity C21 10 Initially zero range 10 Max capacity C21 20 Initially zero range 20 Max capacity C22 Zero tracking range...

Page 20: ...an max capacity C25 Negative display C25 00 Less than 9d C25 10 Less 10 Max capacity C25 20 Less 20 Max capacity C25 50 Less 50 Max capacity C25100 Less 100 Max capacity C26 Standstill time C26 0 Quick C26 1 Medium C26 2 Slow C27 Standstill range C27 1 1d C27 2 2d C27 5 5d C27 10 10d C28 Dynamic filter C28 0 close dynamic filter C28 1 Low dynamic filter C28 3 Medium dynamic filter ...

Page 21: ...er C29 1 Low noisy filter C29 2 Medium filter C29 3 High filter 4 6 Exit setting For example C10 1 Press confirm it then press to exit and save it 5 Output data format 5 1Computer continuous sending format CR LF S 1 S 2 S 3 Data S 4 S1 weight status ST standstill US not standstill OL overload ...

Page 22: ... value including decimal point CR carriage return LF line feed 5 2 Big display continuous sending format Output continuous format S T X S W A S W B S W C X X X X X X X X X X X X C R C K S 1 2 3 4 5 6 State A Bits0 1 2 0 1 2 Decimal point position 1 0 0 XXXXXX0 0 1 0 XXXXXXX 1 1 0 XXXXX X 0 0 1 XXXX XX 1 0 1 XXX XXX Bits3 4 Division 0 1 X1 1 0 X2 ...

Page 23: ... Bits3 dynamic 1 Bits4 unit lb 0 kg 1 Bits5 Constant 1 Bits6 Constant 0 State C Bit2 Bit1 Bit0 unit 0 0 0 Kg or lb 0 0 1 g 0 1 0 t Bit 3 printing 1 Bit 4 Extend display 1 Bit 5 Constant 1 Bit 6 Constant 0 5 3 Serial interface reception command RS232COM serial interface can receive simple ASCII command Command word and role as follows ...

Page 24: ...Print command Print the weight R Read gross net weight Read gross net weight 5 4Print output format NO 004 NO G W 8 88kg gross example for two decimal point T W 2 88kg tare N W 6 00kg net 5 5 Print the accumulated output format NO 004 NO Total 003 accumulate times example for 3 times is 003 Total W 2 88kg accumulate weight ...

Page 25: ...ht 2 check load cell connection 3 checking load cell check input and output resistance to judge it is good or not Display nnnnnn 1 calibration is no good 2 cell single line is connect a wrong line 3 the cell is bad 1 check scale is resisted or not foot is kept level or not 2 check load cell connection 3 checking load cell check input and output resistance to judge it is good or not ERR1 during cal...

Page 26: ...ce the PCB ERR4 During calibration single is unstable Ensure added weight and scale is stable start calibration ERR5 EEPROM check error change PCB 6 2Daily maintenance 1 In order to ensure indicator display clearly and prolong use life the indicator should not be placed directly on sunlight 2 Load cell and indicator should be well connected the system should have a good ground away from strong ele...

Page 27: ... scale calibration Default parameter form parameter instruction Default value C01 Calibration unit 1 C02 decimal digits 0 C03 Division value 1 C04 Max capacity 10000 C05 Empty scales calibration 0 C06 Capacity calibration 0 C07 restore the default parameters 0 C08 Warning tone 1 C09 Automatic power off 0 C10 Power saving mode 0 C11 Hold function 0 C12 Animal weighing mode 0 C13 Upper limit warning...

Page 28: ...ace Baud rate 3 9600 C20 Manual zero setting 2 C21 Initical zero setting 10 C22 Automatic zero tracking range 0 5 C23 Automatic zero tracking time 1 C24 Verload range 9 C25 Negative display range 10 C26 Standstill time 1 C27 Standstill range 2 C28 Dynamic filter 0 C29 Noisy filter 2 C30 C40 Reseverd menu ...

Reviews: