TROUBLESHOOTING:
ProblemPossible Cause/Remedy

• Travel Cooler/Warmer

is not functioning as cooler or warmer (fan is not turning)

• Accessory outlet of DC power supply is not functioning -check by plugging in a

12Volt DC appliance. If not, clean accessory outlet and re-connect the 

Travel

Cooler/Warmer

• Fuse or circuit breaker in accessory outlet is open. Reset breaker or check fuse,

and replace fuse if necessary. 

• Ignition is switched off - start engine or switch ignition to “accessory” position.

• Fuse in unit’s power cord is blown - see Fuse Replacement section for location

of fuse and instructions for checking and replacing fuse.

- Cooler/warmer is not cooling or heating properly (fan is not turning).

• Fan is defective. Call Vector Customer Service department for return/replace-

ment instructions. This unit is not user-serviceable, it must be returned to

Vector Manufacturing for professional service or repair. Any attempt to 

service by user will void warranty.

- Cooler/warmer is not cooling or heating, but fan is turning

• Cooling unit is defective. Call Vector Customer Service department for

return/replacement instructions. This unit is not user-serviceable, it must be

returned to Vector Manufacturing for professional service or repair. Any

attempt to service by user will void warranty.

- Travel Cooler/Warmer takes longer than 2 hours to reach desired temperature inside

• Low battery or supply voltage. 

• Unit will attain desired temperature more efficiently if items are pre-heated or

pre-chilled.

• Fan area is blocked - Move unit or object

SPECIFICATIONS:

Capacity  . . . . . . . . . . . . . 5 Liter / 1.32 Gallons (US)/ 9 can
Power Supply:  . . . . . . . . . 12 Volt DC 
Power Cord:  . . . . . . . . . . 7’, with 12 Volt DC power plug and 10 Amp fuse
Amperage draw:  . . . . . . . 3 Amperes (approx. 36-watts)
Cooling Performance: . . . . Cools to average 40ºF below surrounding air 
Warming Performance:  . . Warms to 120°F above surrounding air.
High Temperature Limit:  . . Automatic ON/OFF.
Cold/Heat Transfer:  . . . . . Temperature-efficient, aluminum-coated liner
Insulation:  . . . . . . . . . . . . CFC-free polyurethane liner
Heat Dissipation:  . . . . . . . Built-in fan with long-life, brushless motor
Warm/Cool System:  . . . . Non-wearing thermoelectric 
Dimensions  . . . . . . . . . . .7”W x 12”D x 10.5”H
Weight   . . . . . . . . . . . . . .4.85 Lbs

Summary of Contents for VEC221

Page 1: ......

Page 2: ...EGARDING THE OPERATION AND WARRANTY OF THIS PRODUCT PLEASE READ CAREFULLY BEFORE USE AND RETAIN FOR FUTURE REFERENCE 4140 S W 28th WAY FT LAUDERDALE FL 33312 Tel 954 584 4446 Fax 954 584 5556 Toll Fre...

Page 3: ......

Page 4: ...hipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading d...

Page 5: ...VECTOR MANUFACTURING Ltd 4140 S W 28TH WAY FT LAUDERDALE FL 33312 AB061103...

Page 6: ...Boat Home or motel use with Vector s VEC002 AC DC Converter At the beach on picnics at the campground use with battery power For short term use When you have to leave the vehicle in the parking lot a...

Page 7: ...r wine juice milk iced tea or coffee shakes thirst quenchers water and more in cans bottles cartons pouches sport bottles etc Foods salads sandwiches deli meats hamburgers hot dogs meat or fish buns c...

Page 8: ...armer is not cooling or heating but fan is turning Cooling unit is defective Call Vector Customer Service department for return replacement instructions This unit is not user serviceable it must be re...

Page 9: ...steps 4 9 for cooler or warmer function OBSERVE ALL CAUTIONS AND WARNINGS FUSE REPLACEMENT The power cord is fuse protected against short circuiting by a 10 amp fuse located in the tip of the 12 Volt...

Page 10: ...unit is intended for portable use only it is not designed to be built in or recessed this would interfere with the unit s air dissipation system and could cause a fire or other safety hazard Use only...

Page 11: ...scribed in the Care Maintenance section of this manual 9 Store in a cool dry area out of direct sunlight CAUTIONS The cooler takes about 2 hours to reach its maximum cool temperature approx 40 F below...

Page 12: ...lean unit as described in the Care Maintenance section of this manual Store in a cool dry area out of direct sunlight CAUTIONS The warmer is intended to maintain the temperature of pre heated food and...

Reviews: