Your new Vector MAXX 400 SST inverter is one in a series of the

mostadvanced DC to AC inverters available today. With proper

careandappropriate usage, it will give you years of dependable service in

your car, truck, RV or boat.

The MAXX 400 SST supplies 400 watts of continuous power, with a 800

watt peak, in the form of two household-type outlets that are ready to

deliver 110 volt AC power whenever and wherever you need it! The heavy-

duty inverter has enough power to run most household or electronic

appliances, including color TVs (up to 25"), TV/VCR combinations, laptop

computers, camcorders, cellular phone, power tool chargers, lamps and

many more. It also comes equipped with battery clips to handle higher

amperage/load applications, such as; power tools, stereo amplifiers (up to

275 watt RMS), etc. Added safety features include automatic shutdown

and a low battery alarm to prevent damage to your battery.

This power inverter is configured with the latest soft start technology (SST)

to improve inverter operation. Before introduction of soft-start, high start-

up currents from large inductive loads could shut down the inverter. Three 

major features are incorporated in SST. First, gradual voltage ramp-

upduring inverter start-up. This eliminates failed cold starts underload.

Second, output that momentarily dips in voltage and quickly recovers. This

eliminates most shutdowns from momentary overloads. Last, the inverter

needs to be turned off then turned on to re-start the inverter when an

overload that caused inverter shutdown is removed. 

This power inverter also incorporates a new cooling technology that

directly benefits our customers. The new design more efficiently cools the

power transistors, and combined with soft start dramatically increases

reliability and the life of the product.

2.

CONTROLS, INDICATORS AND CONNECTORS

Figure 1 details the front panel of the inverter. The front panel provides two

LED indicators. A green LED shows proper operation when lit. The red LED

shows inverter shutdown from overload, over voltage or over temperature.

Power is supplied through two grounded standard North American outlets.

Outlets accommodate either two or three pin AC plugs. An ON/OFF

switch turns the inverter circuitry ON and OFF. The switch is used to force

reset of inverter circuits if it is switched OFF, then ON.

Summary of Contents for VEC024

Page 1: ...AD AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE 4140 SW 28TH...

Page 2: ...C plug connections and ring terminal connections 4 This is not a toy keep away from children CAUTIONS 1 Do not use with positive ground electrical systems the majority of modern automobiles RVs trucks...

Page 3: ...ION 6 4 1 Power Source Requirements 6 7 4 2 Connection to Power Source 7 8 4 3 Connection to Load 8 9 4 4 Placement of Inverter 9 5 OPERATING TIPS 10 5 1 Rated Versus Actual Current Draw of Equipment...

Page 4: ...start up currents from large inductive loads could shut down the inverter Three major features are incorporated in SST First gradual voltage ramp upduring inverter start up This eliminates failed col...

Page 5: ...t converts the high voltage DC into 110 volts 60 Hz AC The DC to DC converter stage uses modern high frequency power conversion techniques that have replaced the bulky transformers found in less techn...

Page 6: ...voltage under the assumption that the waveform measured will be a pure sine wave These meters will not read the RMS voltage of a modified sine wave correctly They will read about 20 to 30 volts low wh...

Page 7: ...volt DC plug firmly into the 12 volt DC socket of a vehicle or other DC power source CAUTION Connect directly to power source when operating above 175 watts NOTE Most automobile 12 volt DC circuits us...

Page 8: ...he positive terminal of the DC source battery 4 Connect a length of wire on one side of the fuse holder or circuit breaker Connect the other end if the wire to the positive terminal of the inverter 5...

Page 9: ...o not use the inverter to recharge items that q can be plugged directly into an AC receptacle This problem does not occur with the majority of battery operated equipment Most of these devices use a se...

Page 10: ...nverter can be manually restarted by reseting the on off switch Resistive loads are the easiest for the MAXX 400 SST to run However larger resistive loads such as electric stoves or heaters usually re...

Page 11: ...SST monitors the following potentially hazardous conditions LOW BATTERY VOLTAGE This condition is not harmful to the inverter but could damage the power source An audible alarm will sound when input...

Page 12: ...emit a buzzing sound from their speakers when operated from the MAXX 400 SST power inverter This occurs because the power supply in the electronic device does not adequately filter the modified sine w...

Page 13: ...alarm Bad connection or wiring Tighten all DC sounds continuously connections Low battery Low battery voltage Recharge battery alarm sounds Remove load from inverter while recharging battery Motorize...

Page 14: ...You may also contact us by visiting our website www vectormfg com 10 SPECIFICATIONS Output Connection Dual North American Standard Receptacles Output Voltage Approx 110 volt AC RMS 60 Hz Output Curre...

Page 15: ...oes not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight acciden...

Page 16: ...2004 VECTOR MANUFACTURING Ltd FT LAUDERDALE FL 33312 MADE IN CHINA VECTOR MANUFACTURING LTD...

Reviews: