5
Battery Replacement/Disposal
Battery Replacement
The built-in battery should be replaced when the operating performance is reduced
to about half. Make sure that the battery is fully charged before determining whether
it should be replaced. The unit must be returned to the manufacturer for replacement.
Do not attempt to open the unit casing, as this may damage the unit and will void
the manufacturer’s warranty. Contact Vector Technical Support, toll-free, at 866-
584-5504.
Battery Disposal
This unit contains a maintenance-free, non-spillable, sealed lead-acid
battery. This battery is fully recyclable and should be accepted at
any location that accepts common automotive batteries. Examples of
places that accept these batteries are: county or municipal recycling
drop-off centers, scrap metal dealers and retailers who sell
automotive replacement lead acid batteries.
WARNINGS
Do not dispose of the battery in fire, as this may result in an explosion.
Before disposing of the battery, protect exposed terminals with
heavy-duty electrical tape to prevent shorting (shorting can result in
injury or fire).
Do not expose battery to fire or intense heat, as it may explode.
SPECIFICATIONS
Compressor:
120 PSI maximum at pump
Current:
Approx. 8 amps
Battery:
12 Volt, 3 A/h, non-spillable, sealed lead-acid
12 Volt DC Power Adapter Fuse: 15 amp
4
7. When desired pressure is reached, open thumb latch and remove connector from
valve stem.
8. Release the Air Compressor Trigger to turn it OFF (unlock the Trigger Lock, if used).
Inflating Items Without Valve Stems
Inflation of items without valve stems requires the use of one of the nozzles. The nozzle
fits directly in the free end of the tire chuck.
1. Open the Nozzle Hatch cover and select the required nozzle.
2. With the tire chuck thumb latch open, firmly insert the nozzle.
3. Close the tire chuck thumb latch.
4. Make sure the Nozzle is clean and secure before turning on the Compressor.
5. Insert nozzle (e.g needle) into item to be inflated and inflate to desired pressure.
6. Press the Air Compressor Trigger to turn it ON.
7. Inflate to desired pressure.
8. Release the Air Compressor Trigger to turn it OFF.
9. After use, release the Nozzle by opening the tire chuck thumb latch and return
the nozzle to the Nozzle Hatch.
WARNING
Always follow manufacturer’s recommendations for pressure on item
to be inflated.
CAUTION
To avoid damage, always secure the Air Hose in its storage clamps when the unit is
not in use. Make sure the tire chuck thumb latch is closed.
USING THE LED WORK LIGHT
The LED Work Light is controlled by the ON/OFF Pushbutton located on the top of the
unit behind the Nozzle Hatch (see “Controls and Functions” on page 2).
CARE AND MAINTENANCE
Cleaning
Periodically, cables, hose, nozzles and connectors should be inspected for damage,
corrosion, dust and dirt. If surfaces are dirty, they can be wiped clean with a cloth
moistened with water and a drop of detergent.
Never submerge this unit in
water or any other liquid.
Replacement Parts
For replacement parts (12 Volt DC Power Adapters, 120 Volt AC Charging
Adapters), contact Vector Technical Support, toll-free 866-584-5504.
Fuse Replacement (12 Volt DC Power Adapter)
1. Disconnect the 12 Volt DC Power Adapter from the unit and from any 12 volt DC
power source.
2. Remove the gold cap by turning counterclockwise and lifting off.
3. Remove center pin and spring. Remove the fuse.
4. Replace with a new 15 amp fuse.
5. Replace center pin and spring inside plug.
6. Replace the gold cap by turning clockwise.
VEC251_Manual_061506.qxp 6/15/06 10:22 AM Page 4