background image

SAFETY INFORMATION

WARNINGS

WARNING STATEMENTS IDENTIFY CONDITIONS OR PRACTICES THAT MAY

RESULT IN PERSONAL INJURY OR LOSS OF LIFE.

1. When working with lead acid batteries, always make sure immediate assistance is 

available in case of accident or emergency.

2. Protective eyewear must be worn when using this product; contact with battery acid may

cause blindness and/or severe burns; be aware of first aid procedures in case of 
accidental contact with battery acid.

3. There is a risk of explosive gases being released when lead acid batteries are being

charged or discharged. Failure to follow instructions may cause property damage, 
explosive hazard, and/or personal injury.

4. Make sure the Safety Switch is Off before connecting battery clamps to discharged 

battery. This will enable the polarity alarm to function.

5. When connecting the battery clamps to a discharged battery, and an alarm sounds, 

do NOT turn on the Safety Switch - the polarity is reversed. Interchange battery clamps
before turning the Safety Switch ON.

6. When charging unit from a 110/120 volt AC electrical outlet in any wet or damp area,

make sure that the outlet used is protected by a Ground Fault Interrupt (GFI) Switch.

7. When charging the unit near water, do not allow the electrical cords and outlets to get

wet or come near water; electrical shock could result!

8. Jumpstart procedures should only be performed in a safe, dry, well-ventilated area.
9. Always store battery clamps in built-in holsters when not in use. Never touch battery

clamps together; this can cause dangerous sparks, power arcing, and/or explosion.

10. When using this unit in proximity to the vehicle’s battery and engine, stand the unit on

a flat, stable surface, and be sure to keep all clamps, cords, clothing and body parts
away from moving vehicle components.

11. Do not wear vinyl clothing when jumpstarting a vehicle; friction can cause dangerous 

static electricity sparks. Remove all jewelry or metal objects that could cause short 
circuits or react with battery acid.

12. Always disconnect the negative (Black) jumper cable first; followed by the positive 

(Red) jumper cable.

13. Never allow red and black clamps to touch each other or another common metal 

conductor; this could cause damage to the unit and/or create sparking/explosion 
hazard. Always store battery clamps in built-in holsters when not in use.

14. Do not expose battery to fire or intense heat as it may explode. Before disposing of 

the battery, protect exposed terminals with heavy-duty electrical tape to prevent 
shorting (shorting can result in injury or fire).

15. Do not smoke or use inflammable items (matches, cigarette lighters, etc.) while 

working on a vehicle’s battery system.

16. Keep unit out of reach of children (whether stored, or in use).

FIRST AID:
1. SKIN:

If battery acid comes in contact with skin, rinse immediately with water, then
wash thoroughly with soap and water. If redness, pain, or irritation occurs, 
seek immediate medical attention.

2. EYES:

If battery acid comes in contact with eyes, flush eyes immediately for a minimum 
of 15 minutes; seek immediate medical attention.

8. SPECIFICATIONS

Model  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .VEC020

Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 VDC

Boost Power  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300 Instantaneous Cranking Amps

Peak Ampere Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .900 Peak Amps

Battery Type  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Sealed, high energy density lead-acid, 

rechargeable, maintenance-free, 
12 volt DC, 15 Amp-hour

Bulb  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 volt 0.2 Amp Krypton

Booster Cables  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .#6AWG welding cable with 

350 Amp copper clamps

Accessory Socket Self-Resetting Breaker  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Amps

Charging Cord  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 volt DC

Adapter/Charger  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110/120 Volt AC (500mA, 

12 Volt DC Output)

Reverse Polarity Detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5 Volts (min)

HEIGHT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8.5 in. (21 cm)

DEPTH  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.0 in (12.5 cm)

WIDTH  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.8 in(24.5 cm)

WEIGHT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.7 Lbs (4.84 Kg

)

9. REPLACEMENT PARTS

For replacement parts (bulbs, batteries, fuses, etc.), contact Vector

®

Customer Service:

(954) 584-4446.
BULB REPLACEMENT
Tools needed - small Phillips screwdriver. Replacement bulbs are available from Vector

®

Customer Service Department; call (954) 584-4446 ext. 19.
1. Unscrew (counterclockwise) and remove two Phillips screws.
2. Remove the lens cover.
3. Remove the burned-out bulb.
4. Replace with a new bulb (12 volt 0.2 amp Krypton bulb) available from Vector

®

Customer Service Department; call (954) 584-4446 ext. 19

5. Snap the lens cover back into place.
6. Replace (clockwise) the screws and carefully tighten. Do not over tighten!

14

3

Summary of Contents for Start-It VEC020

Page 1: ...Y MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE VECTOR MANUFACTURING Ltd 4140 S W 28th Way Ft Lauderdale FL 33312 VEC020 4140 S W 28TH WAY FT LAUDERDALE F...

Page 2: ...blem is not covered by this warranty call our customer service facility at 954 584 4446 for general repair information and charges This limited warranty is the only one that applies to this product an...

Page 3: ...Black jumper cable first followed by the positive Red jumper cable 13 Never allow red and black clamps to touch each other or another common metal conductor this could cause damage to the unit and or...

Page 4: ...ge the unit using the AC charger method 2 Use only the supplied cords adapters for recharging this unit Do not recharge for more than 3 4 hours maximum using 12 volt DC method Recharge unit after each...

Page 5: ...I shows the relationship of the frequency of use between recharging and the expected number of discharge recharge cycles Table I Estimated Battery Life AVERAGE NUMBER OF USES POTENTIAL TOTAL NUMBER JU...

Page 6: ...een recharges will reduce battery life 4 1 110 120 VOLT AC CHARGING IMPORTANT MAKE SURE ALL SWITCHES ARE TURNED OFF DURING RECHARGING Charge unit for full 24 hours prior to first use Recharge unit ful...

Page 7: ...arge the Battery Status Display is active to indicate the level of charge on the battery The leftmost red LED indicates minimum charge on the battery Recharge the battery when that LED is the only one...

Page 8: ...use inflammable items matches cigarette lighters etc while working on a vehicle s battery system When using this jumpstarter in proximity to the vehicle s battery and engine stand the unit on a flat s...

Reviews: