background image

IMPORTANT SAFETY INSTRUCTIONS

Read and Understand all Warnings, Cautions and Notes before operating Power City. Warnings alert the user to
hazardous conditions that can be harmful to people. Cautions alert the user to conditions that can cause property
damage. Notes are important operational information.

KEEP THIS USER’S GUIDE FOR FUTURE  USE.

JUMP-START WARNINGS AND CAUTIONS

!

There is risk of explosive gas being released when batteries are improperly charged or discharged. Failure to
follow instructions may cause property damage, explosion hazard and/or personal injury

!

Do not smoke while jump-starting

!

Only attempt to jump-start a vehicle or boat in a well ventilated area

!

This power system is to be used ONLY on vehicles or boats with 12 volt DC battery systems

!

Do not wear vinyl clothing when jump-starting a vehicle 

friction can cause dangerous static electricity sparks

!

Remove all metal jewelry 

this can cause short circuits. Always use protective eyewear when jump-starting:

contact with battery acid may cause blindness and/or severe burns.

!

Never touch Power City red and black clamps together 

this can cause dangerous sparks, power arcing and/or

explosion

!

Do not attempt to jump-start a frozen battery

!

After use as jump-starter, turn off safety switch

!

Keep out of reach of children

!

Vehicles that have on-board computerized systems may be damaged if vehicle battery is jump started. Before
jump-starting this type of vehicle, read the vehicle’s owners manual to confirm that external-starting assistance
is advised

!

Excessive engine cranking can damage the vehicle’s starter motor. If the engine fails to start after the
recommended number of attempts, discontinue jumpstart procedure and look for other problems that ma y need
to be corrected

!

When safety switch is off, Polarity Alarm is enabled. If cables are connected to another battery and the alarm
sounds, the cable connections must be switched. If alarm sounds, do not turn on safety switch

!

If vehicle to be started has a positive grounded System (positive battery terminal is connected to chassis), replace
steps 9 and 10 of the jump-start procedure (below) with the following steps A and B, and then proceed to step 11

A. Connect negative (

-

) black clamp to vehicle battery ‘s negative terminal.

B. Connect positive (+) red clamp to vehicle chassis or a solid, non-moving, metal vehicle component or

body part. DO NOT clamp directly to positive battery terminal or moving part.

!

Replace worn or defective parts immediately 

contact Vector Technical Support Department at toll-free (866)

584-5504

!

Skin: if battery acid comes in contact with skin, rinse immediately with water, then wash thoroughly with soap
and water. If redness, pain, or irritation occurs, seek immediate medical attention

!

Eyes: if battery acid comes in contact with eyes, flush eyes immediately for a minimum of 15 minutes, seek
immediate medical attention

Summary of Contents for Power City VEC029ACY

Page 1: ......

Page 2: ...zed systems may be damaged if vehicle battery is jump started Before jump starting this type of vehicle read the vehicle s owners manual to confirm that external starting assistance is advised Excessi...

Page 3: ...erter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor use 11 5 2 Warnings 11 5 3 Tire Inflation or products with a valve stem 1 2 5 4 Inflate other articles without valve stem 1 2 5 5...

Page 4: ...Main Unit Away from the Main Unit the Lantern is powered using an extension cord attached to the Inverter power cable This feature is invaluable when it becomes necessary to locate battery terminals...

Page 5: ...uters and printers color TVs up to 13 reading lamps fans small appliances and power hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter...

Page 6: ...end of cable 6 Squeeze negative black clamp handles and slide clamp from holster 7 Carefully lift positive red lumper cable wire from storage channel starting at clamp end of cable 8 Squeeze positive...

Page 7: ...een LED and a red LED The green LED when lit indicates power is applied to the inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The...

Page 8: ...rated away from the main unit the power source must provide between 11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a battery or...

Page 9: ...erse polarity connection will result in damage to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrect polarity the fuse will blow If the unit does not function after...

Page 10: ...ece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure fr...

Page 11: ...DC accessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 volt DC compressor is the ultimate compressor for all vehicles trailer tires and recreational inflatables Three different sized nozzles...

Page 12: ...ery rapidly 5 Insert adaptor e g needle into item to be inflated and inflate to desired pressure 6 Turn on compressor switch inflate to desired pressure or fullness refer to paragraph 5 5 7 Remove ada...

Page 13: ...ached lantern extension cord This allows great flexibility in positioning the lantern during tire inflation and during under the hood inspections See Figure 91 If an alternative 1 2 volt DC source is...

Page 14: ...disposal 7 RECHARGING POWER CITY S BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid batteries suffer from self discharge over tim...

Page 15: ...cable After recharge the accessory cables are stored in their own cable storage hatch in the main unit Recharging the main unit s internal battery from an external DC power source requires the use of...

Page 16: ...nt parts bulbs batteries charging adapters cables etc contact Vector Technical Support toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the lantern there are no user serviceable...

Page 17: ...wer Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 350 Watt 60 Hz 110 120 VAC Inverter Waveform Modified Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm 1...

Page 18: ...es not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accident...

Reviews: