background image

4.7 INVERTER FUSE REPLACEMENT

The following assumes that the main unit battery has a charge and that there is no output from the 110 VA C
receptacle. If you find that a fuse is blown (open) determine the cause of the short before restarting the power
inverter again. Fuse replacement in automobile: Most automobile 12 volt DC accessory outlet use fuses at 1

amps

or greater. The inverter can deliver 180 watts with a 20 Amp lighter socket fuse. The inverter must be removed
from the Main Unit to gain access to the fuse. The fuse, spade lug type 30 amperes) is located under the black
protective cap on the connector end of the inverter.

1.

 

Lift off the protective cap from the inverter and set 

it 

aside.

2. Press the release buttons that hold the inverter in place and slide the inverter out of the mounting.
3. Lift the end of the black protective fuse cover closest to the power pins and rotate upwards to expose top of fuse.
4. Grasp the fuse in the center and pull away from the inverter.

5. 

Check the fuse visually or with a continuity checker.

6. If fuse is open (blown) replace with another with same type and rating.
7. Close fuse cover and slide inverter back into its mounting and place the on/off Switch in the On position.
8. If fuse is good the green LED will light.

9. 

Check for proper operation by powering a 110 VAC appliance. If there is still a problem, call Vector Technical

Support toll-free (866) 584-5504.

 

NOTE:

If the Main Unit battery is discharged, the Inverter may also be quickly checked by connecting the Inverter
Power Cable to the inverter’s power pins and plugging the DC plug into a known to be operating 1 2 volt
DC accessory socket.

5.

COMPRESSOR/TIRE INFLATOR

This built-in 12 volt DC compressor is the ultimate compressor for all vehicles, trailer tires and recreational
inflatables. Three different sized nozzles are supplied. Each nozzle will clip on the end of the standard tire valve
connector located at the free end of the compressor hose. The compressor nozzles are stored inside the cable hatch.
The compressor hose with tire fitting is stored in a retaining channel between the jumper cable channels on the
rear of the unit. The compressor’s on/off switch is located on the side of the main unit near the AC recharge port.
The compressor can operate long enough to fill up to 3 average sized tires before the Power City internal battery
must be recharged. When the compressor is turned on, the gauge will light up.

5.1 COMPRESSOR USE

IMPORTANT: 

Read Instructions Carefully To Avoid Possible Injury Or Property Damage.

The compressor may be used by removing the air hose from it’s storage channel and fitting an appropriate nozzle
to the air hose. An on/off switch located on the main unit controls the power to the compressor. Refer to Figures 2
and 3 for locations of compressor switch and nozzle storage hatch.

For nighttime use: Remove the lantern from the main unit and power it from the extension cord. This way you can
position the Lantern to see the pressure gauge and the item being inflated.
Refer to Section 6, below.

5.2

WARNINGS

The compressor is capable of inflating to 260 pounds per square inch (psi) pressure. To avoid over-inflation,
carefully follow instructions on articles to be inflated. Never exceed recommended pressures. Bursting articles can
cause serious injury. Always check pressure with the pressure gauge Never leave compressor unattended while in
use. Allow unit to cool after 10 minutes of continuous operation.

Summary of Contents for Power City VEC029ACY

Page 1: ......

Page 2: ...zed systems may be damaged if vehicle battery is jump started Before jump starting this type of vehicle read the vehicle s owners manual to confirm that external starting assistance is advised Excessi...

Page 3: ...erter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor use 11 5 2 Warnings 11 5 3 Tire Inflation or products with a valve stem 1 2 5 4 Inflate other articles without valve stem 1 2 5 5...

Page 4: ...Main Unit Away from the Main Unit the Lantern is powered using an extension cord attached to the Inverter power cable This feature is invaluable when it becomes necessary to locate battery terminals...

Page 5: ...uters and printers color TVs up to 13 reading lamps fans small appliances and power hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter...

Page 6: ...end of cable 6 Squeeze negative black clamp handles and slide clamp from holster 7 Carefully lift positive red lumper cable wire from storage channel starting at clamp end of cable 8 Squeeze positive...

Page 7: ...een LED and a red LED The green LED when lit indicates power is applied to the inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The...

Page 8: ...rated away from the main unit the power source must provide between 11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a battery or...

Page 9: ...erse polarity connection will result in damage to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrect polarity the fuse will blow If the unit does not function after...

Page 10: ...ece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure fr...

Page 11: ...DC accessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 volt DC compressor is the ultimate compressor for all vehicles trailer tires and recreational inflatables Three different sized nozzles...

Page 12: ...ery rapidly 5 Insert adaptor e g needle into item to be inflated and inflate to desired pressure 6 Turn on compressor switch inflate to desired pressure or fullness refer to paragraph 5 5 7 Remove ada...

Page 13: ...ached lantern extension cord This allows great flexibility in positioning the lantern during tire inflation and during under the hood inspections See Figure 91 If an alternative 1 2 volt DC source is...

Page 14: ...disposal 7 RECHARGING POWER CITY S BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid batteries suffer from self discharge over tim...

Page 15: ...cable After recharge the accessory cables are stored in their own cable storage hatch in the main unit Recharging the main unit s internal battery from an external DC power source requires the use of...

Page 16: ...nt parts bulbs batteries charging adapters cables etc contact Vector Technical Support toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the lantern there are no user serviceable...

Page 17: ...wer Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 350 Watt 60 Hz 110 120 VAC Inverter Waveform Modified Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm 1...

Page 18: ...es not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accident...

Reviews: