background image

8.2 TROUBLESHOOTING GUIDE

TROUBLE/ INDICATION 

POSSIBLE CAUSE 

SUGGESTED REMEDY

No AC output –

DC input below 10 Volts Recharge or replace

red LED lit 

battery

No AC output – 

Excessive appliance

Reduce load-wait for 

red LED lit 

load-thermal shutdown  inverter to cool. Turn Off

Low battery alarm 

Bad connection or wiringTighten all DC 

sounds continuously  

connections

Low battery  

Low battery voltage 

Recharge battery

alarm sounds

Remove load from 

inverter while recharging

battery

Motorized power tool 

Excessive start-up load

Rock the On/Off switch 

won’t start  

several times. If appliance 

does not start, then

appliance will not work

with inverter

Motorized power tool 

Purely inductive load

Make the load not purely

does not operate at 

inductive. Operate an 

correct speed

incandescent lamp at

same time as motor

Television/Radio 

Snow in picture, buzz 

Keep inverter and

interference

in speaker  

antenna distant from 

each other. Use shielded

antenna cable. Connect

antenna to amplifier and 

ground inverter case

FIGURE 1 –  FRONT PANEL 

FIGURE 2 – BACK PANEL

1) DUAL HIGH SPEED COOLING FANS
2) BLACK NEGATIVE (–) TERMINAL AND RETAINING NUT
3) RED POSITIVE (+) TERMINAL AND RETAINING NUT
4) TERMINAL COVER

1)  THREE NORTH AMERICAN

STANDARD OUTLETS

2)  GREEN LED SHOWS UNIT

IS OPERATING

3) RED LED SHOWS UNIT IS

SHUT DOWN

4) ON/OFF SWITCH

2

21

1

4

3

2

1

3

4

2

Summary of Contents for MAXX SST 1000

Page 1: ...ETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT TO AVOID POSSIBLE INJURY OR PROPERTY DAMAGE PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THIS PRODUCT MAXX SST TM 1000 POWER INVERTE...

Page 2: ...is not a toy keep away from children CAUTIONS NO USER SERVICEABLE COMPONENTS INSIDE OPENING UNIT WILL VOID WARRANTY Do not use with positive ground electrical systems the majority of modern automobil...

Page 3: ...packaging in case you need to ship the unit When returning a product include your name address phone number dated sales receipt or copy and a description of the reason for return and product serial n...

Page 4: ...fan only operates when the inverter s load requires it to operate It shuts off when cooling is not required 9 0 MAINTENANCE The inverters require minimal maintenance However for optimum perform ance...

Page 5: ...l times If appliance does not start then appliance will not work with inverter Motorized power tool Purely inductive load Make the load not purely does not operate at inductive Operate an correct spee...

Page 6: ...ude a high surge capability up to 2 000 watts which is required to start heavy loads such as motors and other inductive devices 8 0 TROUBLESHOOTING 8 1 COMMON PROBLEMS POWER TOOLS AND MICROWAVE OVENS...

Page 7: ...liances into the inverter receptacles to directly recharge their nickel cadmium batteries Always use the recharger provided with that appliance DO NOT plug in battery chargers for cordless power tools...

Page 8: ...he inverter should be as shown in FIGURE 7 Be sure to remove terminal cover and terminal nuts before starting permanent installation Inverter DC cables and fuse installation is as follows 1 Using tool...

Page 9: ...n unattended applications for the UPS floating battery configura tions are for powering sump pumps safety lighting communications equipment burglar alarm systems and computer systems 3 0 THEORY OF OPE...

Page 10: ...ctly A Check all connections and tighten any loose connections B Ensure that the source battery has adequate charge C If steps A through B do not correct the problem contact Vector Customer Service De...

Page 11: ...d terminal nuts 2 Identify the Positive and negative terminals on the 12 volt DC battery and identify the positive and negative terminals on the inverter 4 0 OPERATION NOTE Ensure that the total conti...

Page 12: ...harged If the connections are good and the battery is charged but the voltage still drops below 11 volts you may need to use a larger battery or battery combination 5 2 OPERATING ENVIRONMENT WARNINGS...

Page 13: ...nput voltage drops below 10 5 VDC This built in feature protects the battery from being completely discharged The inverter will also shut down if the input voltage exceeds 15 volts This protects the i...

Page 14: ...the number of amp hours you expect to use should be less than 50 of the battery s rated capacity 100 100 1000 1000 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 900 900 800 800 700 700 600 60...

Reviews: