background image

10

5.

EMERGENCY WORKLIGHT 

The Worklight is controlled by an On/Off switch. Make sure the lamp is turned OFF
when the unit is being recharged or stored.

6.

REPLACEMENT PARTS

For replacement parts (bulbs, batteries, fuses, etc.), contact Vector Customer
Service: (954) 584-4446 or toll-free (866) 584-5504.

6.1

Battery replacement

It is recommended that the unit be returned to Vector Customer Service for 
battery replacement: Contact (954) 584-4446 or toll-free (866) 584-5504.

WARNING

• Do not dispose of the battery in fire as this may result in an explosion
• Before disposing of the battery, protect exposed terminals with heavy-duty 

electrical tape to prevent shorting (shorting can result in injury or fire)

• Do not expose battery to fire or intense heat as it may explode

6.2

Battery disposal:

This unit contains a maintenance-free, non-spillable, sealed lead-acid battery.
This battery is fully recyclable and should be accepted at any location that
accepts common automotive starter batteries.  Examples of places that accept
these batteries are: County or municipal recycling drop-off centers, scrap metal
dealers and retailers who sell automotive replacement lead acid starter batteries.
For more information on recycling this battery, call toll-free (877) 288-7722.

7.  

SPECIFICATIONS

Model No  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VEC012APM
Peak Ampere   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1200 Amps
Boost Ampere   . . . . . . . . . . . . . . . . . 450 Instantaneous Cranking Amps
HEIGHT   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.75 in. (32.39 cm)
WIDTH    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 in (27.94 cm)
DEPTH   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.5 in (13.97 cm)
WEIGHT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 lbs. (7.26 Kg)
Battery Type 

12Volt, 19AH/20HR Sealed, Rechargeable 

Non-Spillable, Maintenance-free, 

Jumper Cables   . . . . . . . . . . . . . . . . . . . . . .Heavy Duty, Welding Cable 
Cables Clamps  . . . . . . . . . . . . . . . . . . . 450 Amp, Heavy Duty Clamps

Area Light   . . . . . . . . . . . . . . . . . . . . . Three high Intensity White LEDs

Accessory Socket    . . . . . . . . . . . . . . . . .Self-Resetting Breaker 20 Amps
DC Charging Adapter   . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Volt DC
AC Charging Adapter   . . .110/120 Volt AC (700mA, 12 Volt DC Output)
Reverse Polarity Detection   . . . . . . . . . . . . . . . . . . . . . . .2.5 Volts (min)

Summary of Contents for JUMP-START SYSTEM

Page 1: ...ng charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to...

Page 2: ...EFORE USING READ AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE...

Page 3: ...tarting Instructions 7 3 CHARGING RECHARGING 8 9 3 1 110 120 Volt AC Charging 9 3 2 12 Volt DC Charging 9 3 3 Estimated Battery Life 9 4 OPERATING AS A PORTABLE POWER SUPPLY 9 5 EMERGENCY WORKLIGHT 10...

Page 4: ...xplosion 9 When using this unit in proximity to the vehicle s battery and engine stand the unit on a flat stable surface and be sure to keep all clamps cords clothing and body parts away from moving v...

Page 5: ...raw more than 20 amps 5 This system is designed to be used only on vehicles with 12 Volt DC battery systems Do not connect to a 6 Volt or 24 Volt battery system 6 This system is not designed to be use...

Page 6: ...erate 12 Volt DC fans inflators fluorescent worklights cellular phones can quick charge a cellular phone by using the phone s 12 Volt DC adapter cord spotlights TVs portable radios cassette or CD play...

Page 7: ...able maintenance free heavy duty new high energy density 19 Amp hour sealed battery Sturdy and unique compact design provides up to 35 hours of completely portable 12 Volt DC power Safe to use transpo...

Page 8: ...ries generate hydrogen gas during normal operation More gas is generated when the battery is charging Hydrogen gas is explosive poisonous to breathe and highly flammable Recommendations for optimum pe...

Page 9: ...SYSTEMS NOTE In the rare event that the vehicle to be started has a Positive Grounded System positive battery terminal is connected to chassis replace steps 3a and 3b above with steps 4a and 4b then...

Page 10: ...Recharge unit every two months when it has not been used 3 1 110 120 Volt AC Charging 1 Simply plug the AC plug of the AC DC adapter charger into any standard 110 120 volt AC wall outlet 2 Plug the ba...

Page 11: ...ge recharge cycles Table I Estimated Battery Life between recharges lifetime of unit s battery Use Recharges 1 1000 5 700 10 500 4 OPERATION AS A 12 VOLT PORTABLE POWER SUPPLY 1 Lift up the cover of t...

Page 12: ...e non spillable sealed lead acid battery This battery is fully recyclable and should be accepted at any location that accepts common automotive starter batteries Examples of places that accept these b...

Reviews: