background image

CHARGER CONTROLS AND INDICATORS

Figure 3 shows the charger control panel of the 

Jump ‘n Charge system

, and

consists of:

Digital Display

- Displays 

F

FU

UL

L

when battery is fully charged, and displays the Fault

Codes listed on page 9.

Polarized Plug

- use with most household extension cords.

2/4/6 Amp  

pushbutton 

- Selects 2/4/or 6 amps .

ON/OFF 

pushbutton - Selects Off/On 

Power 

LED - when lit indicates AC is applied to charger. 

Fault

LED - when lit indicates one or more abnormal conditions exist. 

Alternator Good 

LED 

- Lights when Alternator Check is complete and alternator  volt-

age is good.

NOTE

: Each time the charger rate is changed, the charger sounds a beep. The only

time the selected charge rate does not display at the full selected rate is when

the battery is nearly full and charging at either steps two or three. The display

will show a slow charge rate. To return to 2 Amp setting, press the 2/4/6 Amp

button. When the battery is fully charged, “

FUL

” will be displayed .

NOTE

: Small 12 volt DC batteries such as those used in motorcycles, garden tractors,

ATVs, jet skis, and snowmobiles can be damaged by high charge rates.

ALWAYS select the 2 Amp setting to charge this type of battery. For slower

charging time on larger batteries, select the 2 Amp setting.

ALTERNATOR CHECK PROCEDURE

NOTE:  DISCONNECT THE 110/120V AC FOR THIS FUNCTION

1. Connect positive (+) red clamp to vehicle battery’s positive terminal.
2. Connect negative (-) black clamp to vehicle battery’s negative terminal.
3. Press ON/OFF pushbutton to turn unit on.
4. Press ‘Alternator Check’ pushbutton. The digital display will show bars.
5. After approximately 15 seconds, Alternator Good LED will illuminate.
6. If ‘Fault’ indicator lights, the alternator is not in good working condition and

should be replaced.

REPLACEMENT PARTS

For replacement parts (bulbs, batteries, fuses, etc.), contact Vector Customer Service:

(954) 584-4446 or toll-free (866) 584-5504.

Battery Replacement

It is recommended that the unit be returned to Vector Customer Service for 

battery replacement: Contact  (954) 584-4446 or toll-free (866) 584-5504.

10

Summary of Contents for Jump 'n Charge VEC12B

Page 1: ...04 IF YOU SHOULD EXPERIENCE A PROBLEM WITH YOUR VECTOR PURCHASE CALL TOLL FREE 866 584 5504 IN MOST CASES A VECTOR SERVICE REPRESENTATIVE CAN RESOLVE YOUR PROBLEM OVER THE PHONE BEFORE RETURNING THIS...

Page 2: ...e to property 2 Use of an attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire electric shock or injury to per sons and will void warranty 3 To reduce ri...

Page 3: ...may cause explosion 6 Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A lead acid battery can produce a short circuit current high enoug...

Page 4: ...level can be viewed when the charge status pushbutton is pressed A 12 volt DC power accessory outlet is provided for use with appli ances that can operate from a vehicle 12 volt DC accessory outlet T...

Page 5: ...nsfer 3 Stage Three Top Off Charge voltage is automatically maintained and reduced to a predetermined level while current is adjusted for a safe effective 100 battery charge step down regulation mode...

Page 6: ...ery being charged gases from battery will corrode and damage charger 3 NEVER allow battery acid to drip on charger when reading specific gravity or fill ing battery 4 NEVER operate charger in a closed...

Page 7: ...ns as follows ensuring a good con nection if there is a mistake the Reverse Polarity Indicator will light NEGATIVE GROUNDED VEHICLE Connect the POSITIVE RED charger clamp to the POSI TIVE POS P batter...

Page 8: ...mp button selects the desired charge rate The selected Charge Rate is indicated by a lit vertical LED bar Once clamps are connected AC is connected and there is no reverse polarity condi tion press th...

Page 9: ...ge time by 10 to ensure full charge In most cases battery charge times will vary depending on age and condi tion of battery Smaller batteries should be charged at the lower rate 2 Amps and add an extr...

Page 10: ...LED will light If FAULT LED light comes on we recommend that you take your battery to a cer tified automotive service center for evaluation BATTERY NOT ACCEPTING A CHARGE Make sure that the charger i...

Page 11: ...fully charged FUL will be displayed NOTE Small 12 volt DC batteries such as those used in motorcycles garden tractors ATVs jet skis and snowmobiles can be damaged by high charge rates ALWAYS select t...

Page 12: ...centers scrap metal dealers and retailers who sell automotive replacement lead acid starter batteries For more information on recycling this battery call toll free 877 288 7722 12 Volt DC Power Sourc...

Page 13: ...ving metal vehicle component or body part Never clamp directly to negative battery terminal or moving part If the audible alarm sounds the polarity is not correct Reverse the connections 4 Procedure f...

Page 14: ...rate IMPORTANT Make sure all switches are turned off during recharging Recharge unit fully after each use WARNING Do not recharge for more than 3 4 hours maximum using 12 volt DC method OPERATION FOR...

Page 15: ...t 15 14 Power tools bilge pump 24 10 Car vacuum 80 2 NOTE All times are approximate and based upon a fully charged unit EMERGENCY AREA LIGHT The Area Light is controlled by an ON OFF switch Make sure...

Page 16: ...n shipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fadin...

Reviews: