Try charging another battery, if the FAULT LED does not light, then one of the above

problems exists with the initial battery. Charger will not charge and the fan will not

operate if there is a fault. Call Vector Technical Support toll free: (866) 584-5504.
SULFATED BATTERY
Batteries left in a discharged state for a long period of time are likely to become "sul-

fated". Sulfated batteries cannot accept a high rate of charge since the internal plates

are coated with lead sulfate. To see if a battery in this condition can be "saved", take

it to a service station or battery distributor for professional evaluation and service.
INTERNAL SHORT CELL BATTERY

If the battery being charged has an internal shorted cell, the FAULT LED will light.

If FAULT LED light comes on, we recommend that you take your battery to a cer-

tified automotive service center for evaluation.

BATTERY NOT ACCEPTING A CHARGE

Make sure that the charger is plugged into a "live" 110/120VAC outlet and

POWER LED is lit.

Unplug charger and check battery connections - ensure there is a good connec-

tion with battery terminal and/or vehicle chassis.

Have the battery checked for sulfated condition (qualified service station or bat-

tery distributor).

Check that the correct charge rate has been selected for the battery being

charged.

Ensure that enough charging time has been allowed for-check table for approx-

imate charging times.

VERY COLD BATTERY
If the battery to be charged is extremely cold (in temperatures less than freezing - 0º

C/32º F) it cannot accept a high rate of charge, so the initial charge rate will be slow.

The rate of charge will increase as the battery warms.

9

Summary of Contents for Jump 'n Charge VEC12B

Page 1: ...04 IF YOU SHOULD EXPERIENCE A PROBLEM WITH YOUR VECTOR PURCHASE CALL TOLL FREE 866 584 5504 IN MOST CASES A VECTOR SERVICE REPRESENTATIVE CAN RESOLVE YOUR PROBLEM OVER THE PHONE BEFORE RETURNING THIS...

Page 2: ...e to property 2 Use of an attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire electric shock or injury to per sons and will void warranty 3 To reduce ri...

Page 3: ...may cause explosion 6 Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A lead acid battery can produce a short circuit current high enoug...

Page 4: ...level can be viewed when the charge status pushbutton is pressed A 12 volt DC power accessory outlet is provided for use with appli ances that can operate from a vehicle 12 volt DC accessory outlet T...

Page 5: ...nsfer 3 Stage Three Top Off Charge voltage is automatically maintained and reduced to a predetermined level while current is adjusted for a safe effective 100 battery charge step down regulation mode...

Page 6: ...ery being charged gases from battery will corrode and damage charger 3 NEVER allow battery acid to drip on charger when reading specific gravity or fill ing battery 4 NEVER operate charger in a closed...

Page 7: ...ns as follows ensuring a good con nection if there is a mistake the Reverse Polarity Indicator will light NEGATIVE GROUNDED VEHICLE Connect the POSITIVE RED charger clamp to the POSI TIVE POS P batter...

Page 8: ...mp button selects the desired charge rate The selected Charge Rate is indicated by a lit vertical LED bar Once clamps are connected AC is connected and there is no reverse polarity condi tion press th...

Page 9: ...ge time by 10 to ensure full charge In most cases battery charge times will vary depending on age and condi tion of battery Smaller batteries should be charged at the lower rate 2 Amps and add an extr...

Page 10: ...LED will light If FAULT LED light comes on we recommend that you take your battery to a cer tified automotive service center for evaluation BATTERY NOT ACCEPTING A CHARGE Make sure that the charger i...

Page 11: ...fully charged FUL will be displayed NOTE Small 12 volt DC batteries such as those used in motorcycles garden tractors ATVs jet skis and snowmobiles can be damaged by high charge rates ALWAYS select t...

Page 12: ...centers scrap metal dealers and retailers who sell automotive replacement lead acid starter batteries For more information on recycling this battery call toll free 877 288 7722 12 Volt DC Power Sourc...

Page 13: ...ving metal vehicle component or body part Never clamp directly to negative battery terminal or moving part If the audible alarm sounds the polarity is not correct Reverse the connections 4 Procedure f...

Page 14: ...rate IMPORTANT Make sure all switches are turned off during recharging Recharge unit fully after each use WARNING Do not recharge for more than 3 4 hours maximum using 12 volt DC method OPERATION FOR...

Page 15: ...t 15 14 Power tools bilge pump 24 10 Car vacuum 80 2 NOTE All times are approximate and based upon a fully charged unit EMERGENCY AREA LIGHT The Area Light is controlled by an ON OFF switch Make sure...

Page 16: ...n shipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fadin...

Reviews: