NOTE: In the rare event that the vehicle to be started has a Positive Grounded System 

(positive battery terminal is connected to chassis): Replace steps I and 2 above 
with the following steps, and then proceed to steps 4-6 above.

1. Connect negative (-) black clamp to vehicle battery ‘s negative terminal.
2. Connect positive (+) red clamp to vehicle chassis or a solid, non-moving, metal 

vehicle component or body part. DO NOT clamp directly to positive battery terminal 
or moving part.

CAUTIONS:

• If vehicle fails to start, leave vehicle ignition key turned OFF, turn 

INDUSTRIAL 900™

power 

switch to off, disconnect the negative (-) clamp first, then the positive (+) clamp, and 
discontinue jumpstarting procedure.

• Recharge jumpstart system after each use.

WARNINGS:

• ALWAYS disconnect the negative (Black) jumper cable first; followed by the positive (Red) 

jumper cable.  

• NEVER ALLOW RED AND BLACK CLAMPS TO TOUCH EACH OTHER OR ANOTHER COMMON 

METAL CONDUCTOR—THIS COULD CAUSE DAMAGE TO THE UNIT AND/OR CREATE A SPARK 
AND EXPLOSION.

• There is a risk of explosive gases being released when batteries are improperly charged 

or discharged. Failure to follow instructions may cause property damage, explosive 
hazard, and/or personal injury.

• ALWAYS USE PROTECTIVE EYEWEAR WHEN USING THIS PRODUCT: CONTACT WITH BATTERY 

ACID MAY CAUSE BLINDNESS AND/OR SEVERE BURNS.

• Keep out of reach of children.
• ALWAYS store battery clamps in built-in holsters when not in use. Never touch battery 

clamps together—this can cause dangerous sparks, power arcing, and/or explosion.

FIRST AID:

•  Skin: If battery acid comes in contact with skin, rinse immediately with water, then wash thoroughly with soap 

and water. If redness, pain, or irritation occurs, SEEK IMMEDIATE MEDICAL ATTENTION.

•  Eyes: If battery acid comes in contact with eyes, flush eyes immediately—for minimum of 15 minutes—SEEK 

IMMEDIATE MEDICAL ATTENTION.

2.2 BATTERY REPLACEMENT
IT IS RECOMMENDED TO RETURN UNIT TO VECTOR™ CUSTOMER SERVICE FOR BATTERY REPLACEMENT: 
CONTACT (954) 923-1155

2.3 BATTERY DISPOSAL
Contains a maintenance-free, sealed, non-spillable, lead acid battery which must be disposed of properly. Most
states require recycling—contact your local authority for information.

SEALED LEAD BATTERY, MUST BE RECYCLED OR DISPOSED OF PROPERLY, DISPOSAL QUESTION

?

FOR USA CALL 1-800-RE-USE-PB (738-7372) OR VECTOR™ CUSTOMER SERVICE.

WARNINGS:

•  DO NOT DISPOSE OF THE BATTERY IN FIRE AS THIS MAY RESULT IN AN EXPLOSION.
•  BEFORE DISPOSING OF THE BATTERY, PROTECT EXPOSED TERMINALS WITH HEAVY-DUTY 

ELECTRICAL TAPE TO PREVENT SHORTING (SHORTING CAN RESULT IN INJURY OR FIRE).  

• DO NOT EXPOSE BATTERY TO FIRE OR INTENSE HEAT AS IT MAY EXPLODE.

3. EMERGENCY/WORK LIGHT

Bulb Replacement

To turn work light on or off, simply toggle the switch on the front control panel.
1. Replacement bulbs are available from Vector™ Customer Service Department; call (954) 923-1155. 
2. Remove the lens cover, two phillips type screws—snap out cover.
3. Remove the burned-out bulb.
4. Replace with a new bulb (12-volt 0.7 amp Krypton bulb).
5. Snap the lens cover back into place and replace the two screws—DO NOT OVER-TIGHTEN.

4. CHARGING/RECHARGING

4.1 110-Volt AC Charging

IMPORTANT:

• MAKE SURE SAFETY ON/OFF SWITCH IS IN OFF POSITION DURING RECHARGING.
• Charge unit for full 24 hours, prior to first use.
• Recharge unit fully after each use.
• Recharge unit every two months, when it has not been used.

1. Simply plug the 110-volt AC plug (Fig. 5 #1) of the AC/DC adapter/charger cord into any standard 

110/120-volt AC wall outlet.

2. Plug the 12-volt DC cigarette type plug (Fig. 5 #2) into the 12-volt DC receptacle on the unit.  
3. Charge this device for at least 14-16 hours or until the FULL indicator is lit.
4. NOTE: The unit can be overcharged (which will shorten the life of the battery)—DO NOT charge with AC 

charging procedure for more than 24 hours maximum.

5. Remove the power cord and store in a safe place.
6. When the 110-volt power inverter option is installed on the unit, the inverter ‘s ON/OFF switch must be in 

the OFF position during recharging.

4.2 12-Volt DC Charging
The 

INDUSTRIAL 900™

system also comes with a DC/DC charging cord, for recharging the unit from the 12-volt

DC cigarette lighter socket in a vehicle or boat. Note: This recharging method will NOT recharge the unit as 
effectively as recharging from a 110-volt AC outlet. The 12-volt DC recharging procedure is recommended only
when it is necessary, as continued use of the 12-volt DC recharging procedure may shorten the battery system’s life. 

Figure 5.

1.

2.

3.

4.

12-VOLT DC/DC
CHARGING CORD

110-VOLT AC/DC
ADAPTER/CHARGER

6

7

Summary of Contents for Industrial Series VEC021

Page 1: ...EL VEC023 INVERTER INCLUDED WITH MODEL VEC021AC NOT INCLUDED WITH MODEL VEC021 THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT BEFORE USE...

Page 2: ...RCE 150 WATT INVERTER FOR USE WITH THE INDUSTRIAL SERIES 900 JUMPSTART SYSTEM POWER SUPPLY 10 8 1 Introduction 11 8 2 How the Vector Power Force 150 Inverter Works 11 8 2 1 Principle of Operation 12 8...

Page 3: ...EHICLES APPLIANCES THE INDUSTRIAL SERIES 900 JUMPSTART SYSTEM AND OR THE POWER FORCE INVERTER IMPORTANT ALTHOUGH THIS UNIT IS DELIVERED IN A PARTIALLY CHARGED STATE YOU MUST FULLY CHARGE IT WITH THE S...

Page 4: ...players and more Can quick charge a cellular phone by using the phone s 12 volt DC adapter cord VEC021AC INDUSTRIAL SERIES 900 JUMPSTART SYSTEM POWER SUPPLY Jumpstart System and 12 volt DC 110 volt AC...

Page 5: ...OCCURS SEEK IMMEDIATE MEDICAL ATTENTION EYES IF BATTERY ACID COMES IN CONTACT WITH EYES FLUSH EYES IMMEDIATELY FOR MINIMUM OF 15 MINUTES SEEK IMMEDIATE MEDICAL ATTENTION FEATURES Heavy duty INDUSTRIAL...

Page 6: ...ey for longer than 5 6 seconds 6 After vehicle starts turn jumpstart system s power switch to OFF position Remove clamps disconnect the negative Black jumper cable first followed by the positive Red j...

Page 7: ...information SEALED LEAD BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY DISPOSAL QUESTION FOR USA CALL 1 800 RE USE PB 738 7372 OR VECTOR CUSTOMER SERVICE WARNINGS DO NOT DISPOSE OF THE BATTERY IN F...

Page 8: ...NG DO NOT RECHARGE FOR MORE THAN 3 4 HOURS MAXIMUM USING 12 VOLT DC METHOD 1 NOTE If unit is fully discharged it is recommended that the vehicle being used for recharging be left running while the uni...

Page 9: ...nd wherever you need it Simply plug the inverter directly into the INDUSTRIAL 900 12 volt DC socket to provide 110 volt AC power for almost any small household or electronic appliance including color...

Page 10: ...this circuit To ensure years of reliable service the power inverter must be installed and used properly Please read the installation and operating instructions thoroughly prior to installation and us...

Page 11: ...THAT PRODUCE HEAT SUCH AS HAIR DRYERS MICROWAVE OVENS AND TOASTERS 8 4 2 Battery Operating Time SEE TABLE IV ON PAGE 10 8 5 TROUBLESHOOTING 8 5 1 Protective Features of the Power Force 150 The Power F...

Page 12: ...n some inexpensive audio systems does not adequately filter the inverter s modified sine wave RECOMMENDATIONS Turn inverter switch OFF then ON again Repeat if necessary Recharge replace source battery...

Page 13: ...r repair neglect misuse abuse failure to follow instructions for care and maintenance fire flood and Acts of God If your problem is not covered by this warranty call our customer service facility at 9...

Reviews: