1. INTRODUCTION ....................................................................................... 5, 6

2. USING VECTOR JUMPER AS A JUMP-START SYSTEM ................................ 7

2.1 Easy, Step-by-Step Jump-starting Instructions ................................... 8

3. CHARGING/RECHARGING ........................................................................ 9

3.1 110/120 Volt AC Charging ................................................................ 9

3.2 12 Volt DC Charging ......................................................................... 10

3.3 Estimated Battery Life ...................................................................... 10

4. OPERATING AS A PORTABLE POWER SUPPLY .......................................... 10

5. EMERGENCY/WORKLIGHT ....................................................................... 11

6. COMPRESSOR/TIRE INFLATOR ................................................................ 11

6.1 Warnings for Compressor Use ........................................................... 11

6.2 Tire Inflation or Products (w/ Valve Stem) ......................................... 12

6.3 Inflate other Articles (w/out Valve Stem) ........................................... 12

6.4 Typical Inflation Times ...................................................................... 12

7.  REPLACEMENT PARTS ........................................................................... 13

7.1 CCFL ................................................................................................ 13

7.2 Battery Replacement ........................................................................ 13

7.3 Battery Disposal ............................................................................... 13

8.  SPECIFICATIONS ................................................................................... 13

9.  WARRANTY ........................................................................................... 14

  Manual 022APC

12/20/02, 8:40 PM

2

Summary of Contents for 022APC

Page 1: ...NTENANCE AND STORAGE OF THIS PRODUCT BEFORE USING READ AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD R...

Page 2: ...attery Life 10 4 OPERATING AS A PORTABLE POWER SUPPLY 10 5 EMERGENCY WORKLIGHT 11 6 COMPRESSOR TIRE INFLATOR 11 6 1 Warnings for Compressor Use 11 6 2 Tire Inflation or Products w Valve Stem 12 6 3 In...

Page 3: ...ody parts away from moving vehicle components 9 Do not wear vinyl clothing when jump starting a vehicle friction can cause dangerous static electricity sparks Remove all jewelry or metal objects that...

Page 4: ...ems Do not connect to a 6 Volt or 24 Volt battery system 6 This system is not designed to be used as a replacement for a vehicular battery Do not attempt to operate a vehicle that does not have a batt...

Page 5: ...TEM to Jump start any engine system with a standard 12 Volt DC battery boat truck car airplane RV personal watercraft snowmobile garden tractor gasoline engine generator etc Operate 12 Volt DC fans in...

Page 6: ...Inflation Adapters included not shown ADDITIONAL FEATURES Includes non spillable maintenance free heavy duty new high energy density 19 Amp hour sealed battery Sturdy and unique compact design provid...

Page 7: ...drogen gas during normal operation More gas is generated when the battery is charging Hydrogen gas is explosive poisonous to breathe and highly flammable Recommendations for optimum performance of the...

Page 8: ...4 Procedure for jump starting POSITIVE GROUND SYSTEMS NOTE In the rare event that the vehicle to be started has a Positive Grounded System positive battery terminal is connected to chassis replace ste...

Page 9: ...echarge unit every two months when it has not been used 3 1 110 120 VOLT AC CHARGING 1 Simply plug the AC plug of the AC DC adapter charger into any standard 110 120 volt AC wall outlet 2 Plug the bar...

Page 10: ...fe between recharges lifetime of unit s battery USE RECHARGES 1 1000 5 700 10 500 4 OPERATION AS A 12 VOLT PORTABLE POWER SUPPLY 1 Lift up the cover of the unit s 12 Volt DC accessory receptacle See F...

Page 11: ...e side of the Main Unit near the AC Recharge Port The compressor can operate long enough to fill up to 3 average sized tires before the battery must be recharged The compressor may be used by removing...

Page 12: ...sert appropriate adapter e g needle into connector chuck and close thumb latch 3 Refer to Table III Typical Inflation Times for approximate filling pressure and time Small items such as volleyballs fo...

Page 13: ...should be accepted at any location that accepts common automotive starter batteries Examples of places that accept these batteries are County or municipal recycling drop off centers scrap metal dealer...

Page 14: ...ssories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during s...

Page 15: ...15 Manual 022APC 12 20 02 8 40 PM 15...

Page 16: ...16 2002 VECTOR MANUFACTURING Ltd FT LAUDERDALE FL 33312 MADE IN CHINA 112202 Manual 022APC 12 20 02 8 40 PM 16...