"WHHR Midi" - WHOLE HOUSE HEAT RECOVERY UNIT
INSTALLATION AND OpERATINg & MAINTENANCE INSTRUCTIONS

Safety Notice

It is important to read this Instruction Manual carefully before installing or using the product.  Following
these instructions will ensure that your ventilation system is installed, commissioned and used properly and
continues to operate effectively.  Vectaire will not be held responsible and will not accept liability for any dam-
age caused to persons or property through failure to follow the guidance provided in this manual.   It should
always be available with the product for easy reference.

WHHR - Midi:

5"/125mm spigot, for dwellings up to 230m

2

, max capacity 102 litre/sec

Midi-Lite:

5"/125mm spigot, for dwellings up to 140m

2

, max capacity 62 litre/sec

general Information

The Vectaire WHHR Midi heat recovery system provides whole house
mechanical ventilation to living areas, bedrooms, kitchen and bathrooms.
It extracts stale, contaminated air from kitchens, utility rooms and bath-
rooms, and uses the heat recovered from this air to warm fresh, incom-
ing air to create a flow of fresh, filtered air throughout the dwelling.  The
extract and intake air streams are separated to avoid contamination.

The system will operate continuously to create a stable, comfortable,
healthy environment avoiding the use of excessive energy and saving
heat already generated.

The heat recovery unit must be installed vertically, and will generally be
sited in a cupboard.  It will be connected by hidden ductwork to vents
sited in the ceilings of the rooms which are to be ventilated.  Each unit
is commissioned individually so that the amount of air moved is tailored
to suit the performance required.  There will be a facility to boost the
extraction rate when desired (e.g when cooking or bathing, or when pol-
lutant levels rise).  This may be done automatically or manually.  

The system is designed to run continuously and should NOT be switched off except for maintenance or filter
replacement.   It is important to follow the advice in this user manual and correctly install and maintain the
system to ensure a healthy and comfortable indoor environment. 

Features
•    SAp pCDB Listed

whole house heat recovery units giving continuous ventilation in the kitchen and up to seven

     additional wet rooms (using rigid ducting)

    low noise levels

    variable choice low (trickle) speed and boost options for optimum setting at installation

    boost speed triggered by a switched live connection from:

     -    a light switch (if more than one light switch is used, 

each one must be a double pole switch)

     

-    DRH240 (dynamic remote humidistat)

     -    PIRFF (passive infra red)
     -    THM (thermostat)

     

-    a remote switch/pull cord 

     or via LCD control panel 

•    Can be mounted with left or right hand drainage and ducting 
•    Economical EC motor with electronic control plus:

    

Standard control features

:

     

>

   

variable adjustment 

- trickle and boost speeds set at installation for both motors independently

     >    boost setting

- with integral overrun timer adjustable up to 20 minutes 

 >

optional delay-on-timer -

boost speed does not operate if switched off within 2 minutes

     >   integral frost-stat -

proportionately reduces intake motor speed as temperature falls

     >   purge boost 

- for rapid air change

     > BMS connections

- for remote motor shut off

Installation MUST be carried out by suitably qualified personnel and MUST be in accordance with current IEE 

     regulations

Incoming

fresh air

Warmed

fresh air

Cooled

outgoing

stale air

Outgoing stale air