6
©Vecow RCX-1000 User Manual
GENERAL INTRODUCTION
Power
Input Voltage
6V to 36V, DC-in
Power Interface
3-pin Terminal Block : V+, V-, Frame Ground
Ignition Control
16 Mode (Internal)
Remote Switch
3-pin Terminal Block : On, Off, IGN
Surge Protection
Up to 80V/1ms Transient Power
Others
TPM
Optional Infineon SLB9665 supports TPM 2.0, LPC interface
Watchdog Timer
Reset : 1 to 255 sec./min. per step
Smart Management
Wake on LAN, PXE supported
HW Monitor
Monitoring temperature, voltages. Auto throttling control when
CPU overheats.
Software Support
OS
Windows 10, Linux
Mechanical
Dimension
330.0mm x 210.0mm x 172.0mm (12.99" x 8.27" x 6.77")
Weight
4.9 kg (10.8 lb)
Mounting
Wallmount by mounting bracket
Environment
Operating Temperature
35W TDP CPU :
-40°C to 75°C (-40°F to 167°F)
65W TDP CPU :
-40°C to 55°C (-40°F to 131°F)
80W TDP CPU :
-40°C to 45°C (-40°F to 113°F)
Storage Temperature
-40°C to 85°C (-40°F to 185°F)
Humidity
5% to 95% humidity, non-condensing
Relative Humidity
95% at 75°C
Shock
• IEC 60068-2-27
• SSD : 50G @wallmount, Half-sine, 11ms
Vibration
• IEC 60068-2-64
• SSD : 5Grms, 5Hz to 500Hz, 3 Axis
EMC
CE, FCC, EN50155, EN50121-3-2