3 COMPONENTS INSTALLATION
3.1 - FUNCTIONING OF THE AIR-CONDITIONERS
During the cooling cycle, the refrigerant circuit transfer the heat from the
ambient air to the sea water.
It is possible to select the functioning cycle, the desired temperature and
the fan speed from a remote control panel that can be installed in the
air-conditioned room.
For detailed information about the control panel, please refer directly to the
remote control panel manual.
While choosing the unit position, it's important to consider the following elements:
1 - the accessibility to the air filter for cleaning operations
2 - the necessary space to fast of the provided clamps
3 - the connection for the condensation drainpipes
4 - there are two possible orientations of the air discharge. Choose the best for connecting the air ducts
5 - the passing of the sea water circuit pipes
6 - the passing of the electrical connection wires and the easy access to the electrical box
Place the pipe-tightening clamps of the water system so that once the unit is arranged, it is still possible to tight the screws.
We suggest to use all stainless steel components.
3.2 - POSITIONING
Versione FANCOIL EV.
Dis. 3-1
3.3 - PLACING
A.- The unit has been designed to
take the ambient air directly away,
therefore it must be installed in the
room that has to be conditioned.
B.- The conditioned air (from the fan) must be piped towards one or more grills through flexible pipes or through
isolated ducts of suitable section in the boat structure.
Dis. 3-2
Dis. 3-5
Dis. 3-3
Dis. 3-4