LAF-P50 & LAF-P100/150

             

User instructions for collecting vessel with built-in pump, model LAF-P50 and LAF-P100/150

The collecting vessel with pump is used if the condensate from the dehumidifier cannot be discharged by hose 

connection directly to drain. The pump is equipped with a level switch that automatically starts and stops the 

pump.

If the pump should fail for any reason to empty the collecting vessel, the dehumidifier will be stopped  

automatically by the level switch and the LED on the dehumidifier will light up with a steady light.

The LAF-P50 is designed for use with dehumidifiers LAF 50, LAF 50S LAF 50E, LAF 50ES, LAF 50E2 

and LAF 50E2S.

The LAF-P100/150 is designed for use with dehumidifiers LAF 100, LAF 100E, LAF 150 and LAF 150E.

Power supply voltage: 230V

Hose connection: 13mm i.d. and 25m max. hose length. To avoid the risk of kinking, do not use  

  

                 excessively thin-wall hose.

Max. delivery head of pump: 3m

Installation

1. Place the collecting vessel in position in the humidifier and connect the hose to the pump outlet as

    shown in Fig. 1. For particulars of max. hose length and pump delivery head, see data above.

2. Connect the dehumidifier plug to the collecting vessel outlet as shown in Fig. 2. Then connect the

    collecting vessel plug to a 230V wall socket.

3. Start the dehumidifier.

Cleaning / maintenance

N.B. Disconnect the collecting vessel from the power supply before cleaning it.

Flush the collecting vessel inside with water from time to time in order to avoid dirt entering the pump.

Figure 1

Figure 2