LVP300 LED HD Video Processor
27
5
)
Brightness level
bright level
description
0-64
0 is minimum brightness, 64 is default standard
brightness.
0-100
Allow higher brightness value: 0 is minimum and 50 is
default value.
According to different demands, user can select relative “Bright Level”. “6.7 Device
Reset” will not change the parameter of “bright level”. When multiple units doing cascading splice,
all units must be same “bright level”. Operation is as below:
Enter “6.5 Bright Level”, rotate knob to select “0-64” or “0-100”, and press “OK” button to confirm
the setup.
6
)
DVI hotplug
“DVI hot plug signal” is sent by processor to graphic card or other signal source
devices, as a proof for signal source device to identify whether outputs DVI signal
source or not. A few PC when use some software play video on extended desktop, the
“hot plug signal” to the device may cause the player out of order on extended desktop.
If this happens, please enter setup menu “6.6 DVI Hotplug” to turn this function off.
7
)
Device Reset
The menu is used to initialize LVP300. Operation as below:
Enter “6.7Device Reset” and press OK button, there is one information on LCD screen to