Tab key (F3) is used for changeover from one digit of phone number to another. 

 

After all phone numbers from “Phone 1” to “Service 2” is entered as mentioned above, push 
the enter key (F4) and return to main page. 

6.1.5.

 

E-MAIL 

 

“E-Mail”  submenu  is  selected  on  the  menu 
page  by  the  value  increase  (F1)  and  decrease 
(F2) keys. The page shown on the left appears 
when  enter  key  (F4)  is  pushed.  The  choice  of 
submenus  on  e-mail  page  is  changed  by 
pushing  increase  (F1)  and  decrease  (F2)  keys. 
After choosing a submenu, the adjustments for 
this  submenu  is  made  by  pushing  enter  key 
(F4).  If  you  want  to  exit  this  page,  push  the 
backspace key (F3). 

 

 

Activation or deactivation of e-mail function can be adjusted from “E-mail” submenu. If you 
want  to  activate  this  function,  choose  “on”  by  pushing  the  enter  key  (F4).  If  you  want  to 
deactivate e-mail function, choose “off” by pushing the enter key (F4).  

 

Ethernet  settings  should  be  adjusted  by  technical  service  staff  for  the  first  usage. 
Otherwise, this function does not work. 

 

“E-Mails” is the page which e-mail addresses will be written on. 

 

 “Login” is the adjustments for the e-mail addresses. 

 

“E-Mails”  is  selected  on  the  e-mail  page  by  the 
value  increase  (F1)  and  decrease  (F2)  keys.  The 
page  on  the  left  appears  when  enter  key  (F4)  is 
pushed. The e-mail addresses can be typed in this 
page and e-mail is sent to these addresses in case 
of any failure.  

 

Each  character  of  e-mail  addresses  is  typed  one  by  one.  The  first  character  is  entered  by 
pushing value increase (F1) and decrease keys (F2) and tab key (F3) is pushed to enter the 
second  character.  The  second  character  is  written  by  pushing  value  increase  (F1)  and 
decrease keys (F2) and tab key (F3) is pushed to enter the next character. After all characters 
are written completely  in this way, push the enter key (F4) to enter the  mail server. After 
mail server is written in the same way, push the enter key (F4) to write next e-mail address. 

 

After all e-mail addresses from 1 to 5 are written as mentioned above, push enter key (F4) 
and return to main page. 

 

Tab key (F3) is used for changeover from one character of address to another. 

 

Summary of Contents for nuve DirectFREEZE DF 290

Page 1: ...N VE SANAY MALZEMELER MALAT VE T CARET A DF 290 DF 490 DF 590 DirectFREEZE ULTRA LOW TEMPERATURE DEEP FREEZER INSTRUCTION MANUAL 1984 Z14 K 25 276 Rev No 08 Rev Date 01 2018...

Page 2: ...ate damaged instrument 4 do not operate instrument with a damaged cable 5 do not move instrument during operation In case of a problem contact your N ve agent for an authorized service or maintenance...

Page 3: ...nditions use of the product in non standard environmental conditions including but not limited to failure to meet requirements of ambient temperature lubrication humidity or magnetic field influences...

Page 4: ...PERATION 14 OPERATING PRINCIPLES 14 PROGRAMMING 14 6 1 1 OPERATING MODE 14 6 1 2 SETTINGS 15 6 1 3 MEMORY 16 INTERNAL MEMORY 17 EXTERNAL MEMORY USB STICK 18 6 1 4 SMS 19 6 1 5 E MAIL 20 6 1 6 SET TEMP...

Page 5: ...ed on the door protects air leakage DF series Ultra Low Temperature Freezer has audible and visual alarm systems for the following cases high and low temperature conditions power failure temperature s...

Page 6: ...Alarm Back up 12 hours with automatically recharged battery Alarm System Audible and Visual Temperature Alarm Range Set point 5 C to 25 C Safety System Pressure Switch Automatic reset Pressure Switch...

Page 7: ...s DF 290 and DF 490 A 08 196 Rack with two drawers DF 590 A 08 197 Rack with three drawers DF 590 A 08 198 Rack for 133 x 133 x 75 mm cryoboxes Rack capacity 20 boxes DF 590 A 08 199 Rack for 137 x 13...

Page 8: ...tant circumstances Notified Body KIWA Belgelendirme Hizmetleri A TOSB stanbul Tuzla Organize Sanayi B lgesi Tepe ren Mevkii 34597 Tuzla stanbul TURKEY Before operating the instrument this manual shoul...

Page 9: ...erature 5 C to 30 C Maximum relative humidity for temperature up to 31 C 80 Maximum altitude 2000 m Temperature for maximum performance 15 C 25 C If ambient temperature is higher than 30 C freezer may...

Page 10: ...the supplied mains matches the required power ratings which are written on the name plate of the instrument located at the back of the instrument Always plug in the instrument to correctly grounded s...

Page 11: ...ION Figure 1 Figure 2 CONTROL PANEL CHART RECORDER OPTIONAL DOOR HANDLE CONDENSER FILTER USB PORT 1 USB PORT 2 ETHERNET RS 232 CO2 BACK UP OUTPUT FUSES POWER CORD POWER LED NC CONTACT OUTPUT REMOTE AL...

Page 12: ...compartments different from DF 490 and DF 590 Figure 3 CONTROL PANEL Figure 4 The functions of F1 F2 F3 and F4 buttons depend on the meaning of the corresponding symbol appearing on the display The fo...

Page 13: ...eturn the previous page or exit from the page by pushing the button corresponding to this symbol This symbol denotes the value increase key You can increase the value by pushing the button correspondi...

Page 14: ...ends on the ambient temperature Suitable room conditions should be considered for best performance Efficient performance at 86 C requires ambient temperature of 16 C OPERATING PRINCIPLES PROGRAMMING A...

Page 15: ...2 SETTINGS Settings page appears when settings submenu is selected from the menu page by the value increase F1 and decrease F2 keys The required submenu is chosen by using the value increase and decr...

Page 16: ...n time of screen saver is adjusted on screen saver time in minutes If you want to exit this page without any change push the backspace key F3 It is suggested to use Screen Saver as ON for energy savin...

Page 17: ...e earlier Push the value increase F1 and decrease F2 keys to pass the other page Push the backspace key F4 in order to exit the page History TABLE submenu is selected on the memory page by the value i...

Page 18: ...alue getting smaller a more detailed graph appears EXTERNAL MEMORY USB STICK USB Stick is connected to USP port 1 of the communication unit Figure 2 appears on the operating mode screen when the USB s...

Page 19: ...ng SMS The user is notified again by sending SMS if the failure still continues Repeat time can be adjusted to 8 hours 16 hours and 24 hours by pushing enter key F4 SMS Numbers is selected on the SMS...

Page 20: ...irst usage Otherwise this function does not work E Mails is the page which e mail addresses will be written on Login is the adjustments for the e mail addresses E Mails is selected on the e mail page...

Page 21: ...rom one character of address to another 6 1 6 SET TEMPERATURE When the setting key F2 is pushed in the operation mode password page appears This password is the user s password The password is 0000 fo...

Page 22: ...artment Figure 5 Icing on the door gasket may be observed In this case the door will not be closed strictly and the icing in the chamber will start Therefore the cooling may not be effective Please ch...

Page 23: ...y is present ERROR CODES Blue colored screen turns into red in case of any failure and a short explanation of the error appears at the bottom line on the red screen Push the key corresponding to quest...

Page 24: ...always be replaced by authorized personnel OPTIONS AlerText GSM MODULE In case of error DF series can send SMS to five different phone numbers by GSM module as an option Figure 6 Figure 7 Figure 8 Pl...

Page 25: ...pears in the error history If the GSM module is connected and cannot send messages SMS error code appears in the error history Modem and SMS errors do not appear when SMS submenu on the SMS page is se...

Page 26: ...the hole at the back of the unit by paying attention to and poles Always use leak protected high quality batteries Put the battery unit to its place Turn the nut in the center 1 to counterclockwise di...

Page 27: ...27 Figure 11...

Page 28: ...28 ELECTRICAL CIRCUIT DIAGRAM DF 290 DF 490 AND DF 590 ELECTRICAL CIRCUIT DIAGRAM...