PROBLEM

PROBABLE CAUSE

SOLUTION

On giving a command with

the remote

control or with the

key-switch, the barrier

doesn’t open or the

motor doesn’t start

230 volt mains voltage

absent

Check master switch

Emergency STOP present

Check for any STOP

selectors or commands.

If not used, check

jumper on STOP contact

input on the control board

Fuse blown

Replace with one of same

value.

Power cable of motor or

motors not

connected or faulty.

Connect the cable to

appropriate

terminal or replace.

The photocell is not

functioning or the

beam is interrupted

Check the connection,

remove any

obstacle across the beam

On giving a command with

the remote control, the

barrier doesn’t open but

works with the key

command

The remote control has

not been

memorised or the battery

is flat

Carry out the remote

control learning

procedure on the radio

receiver or replace the

battery with a new one..

The barrier starts, but

stops immediately

The force of the motor or

motors is insufficient

Modify the value with the

FORCE trimmer on the

control unit

N.B. - If the problem persists, contact your Retailer or the nearest Service
Centre

TROUBLESHOOTING

All products are guaranteed for 2 years, as per the date on the invoice or on the receipt.

The warranty also does not include: failures or damages caused by faults of the electrical system
and/or carelessness, negligence or inadequacy of the installation to the use for which it is intended
and in any case from abnormal use; failures or damages due to tampering by unauthorized
personnel or the use of components not attributable to the manufacturer and/or non-original spare
parts; defects caused by chemical agents, external bodies or atmospheric and/or natural
phenomena in general; failures or damages caused by incorrect installation of the Products
according to the rule of art, safety and conformity of use expressly indicated in the technical
documentation of the same Products; the consumables; interventions for checks and assessments
of any flaws or defects then not found; compensations for the period of inactivity of the system
where the Products are installed.

Summary of Contents for ITALO

Page 1: ...talling thoroughly read this manual that is an integral part of the pack The CE mark conforms to European directive EEC 89 336 92 31 93 68 D L 04 12 1992 N 476 Our products if installed by qualified personnel capable to evaluate risks comply with norms UNI EN 12453 EN 12445 ...

Page 2: ...S 12 Pag PACKING CONTENTS 1 BARRIER 1 BAR SUPPORT TECHNICAL DATA 230V Maximum length of bar 3 mt Motors power supply 230Vac Motor power 250 W Motor RPM 1400 Condenser 16 µF Mechanical unlock for emergency manoeuvre Mechanical Working temperature 20 C 55 C Weight 45Kg Protection rating IP 44 Limit switch Electromechanical Opening time 3 sec ...

Page 3: ...Ÿ The installation and testing operations must be performed by qualified personnel in order to guarantee the proper and safe operation of the automatic gate Ÿ The company declines any responsibility for damage caused by incorrect installations due to incompetence and or negligence ...

Page 4: ...or plate INSTALLATION Set up an electrical multi duct conduit in the middle of the foundation of the barrier corresponding to the central hole corrugated diameter 25 50mm Place the barrier on the floor plate and fasten it with the self locking M12 nuts supplied Brackets Base plate Cable conduit hole INSTALLATION WITHOUT BASE PLATE Place the barrier and block it through the four holes present inter...

Page 5: ...er the motor until reaching the desired opening Note When you open the cover the automation blocks MANUAL OPENING SHAFT SUPPORT Insert the bar support on the shaft and fasten it with screws Insert the bar in the support and tighten the screws Screw Shaft Screw Key Bar support ...

Page 6: ...ed as follows SX DX Discharge the spring tension Unhook the spring Unhook the arm Reverse the position of the spring with the arm Hook again and tighten everything Invert the position of the key from position A to B of the output shaft Reinsert the rod holder A A B B key Front view transmission shaft Sprin arm ...

Page 7: ...switches Adjustment screw for the mechanical limit switches LIMIT SWITCHES REGULATIONS It s possible to adjust the limit switches position both the mechanical placed inside the barrier and electrical ones easily accessible as they are placed under the superior cover N B When one of the mechanical end stroke switches is repositioned it is necessary to relocate the electronically controlled one acco...

Page 8: ...motors is insufficient Modify the value with the FORCE trimmer on the control unit N B If the problem persists contact your Retailer or the nearest Service Centre TROUBLESHOOTING All products are guaranteed for 2 years as per the date on the invoice or on the receipt The warranty also does not include failures or damages caused by faults of the electrical system and or carelessness negligence or i...

Page 9: ...NOTE ...

Page 10: ...NOTE ...

Page 11: ...NOTE ...

Page 12: ...d by electromagnetic fields The presence of inflammable gases or fumes is a grave danger to safety Set up a safety device for overvoltage a disconnecting and or differential switch suitable for the product and conforming to current standards The manufacturer declines any and all responsibility for product integrity safety and operation in the event incompatible devices and or components are instal...

Reviews: