3 - 4
GB
With option 5 ON, the control unit can works with RS485 digital encoder.
Follow the next steps for encoder programmation:
Initial conditions:
-
Door at rest.
- You must connect a push button for open on terminals 26-28 and a push button for close on terminals 26-27.
-
OPTION 5 ON
Open and close push buttons, will used to adjust the door closed and open positions, during the programmation process.
Process:
-
Press PROG button during 1,5 sec. PROG led remains ON.
- With CLOSE push button, adjust the door to close position.
- After adjusting push PROG button during 1,5 sec. PROG led will flash.
- With OPEN push button, adjust the door to open position. (DEAD MAN)
- After adjusting push PROG. during 1,5 sec.
- Flashing light output will activated.
- Press CLOSE push button.
- Control unit will activate the motor to door closed position (adjusted previously) and will exit from programmation process. PROG led OFF.
9. ENCODER RS 485 (KOSTAL)
8. DOOR OPEN RELAY & DOOR CLOSED RELAY
Door open relay is activated when the control unit reaches the position adjusted by the encoder or when the open limit switch is activated.
Door closed relay is activated when the control unit reaches the position adjusted by the encoder or when the close limit switch is activated.
The relays have normally open output contacts, when it reaches the active position the contact closes. If desired the
reverse action must activate I6.
10. SLUICE FUNCTION
CLOSED
DOOR
CONTROL
UNIT 1
CONTROL
UNIT 1
CONTROL
UNIT 2
CONTROL
UNIT 2
CLOSE
15 16
15 16
STOP
STOP
25 26
25 26
- Connect closed door relay
to next control unit STOP input.
output
- POWER 1R0: Equipment with plastic
housing.
POWER 1R0
- POWER K 1R0: Equipment with plastic box housing
and push buttons (frontal membrane).
11. VERSIONS
STO
P
POWER 1R0
0
5
/0
2
/1
4